AIR CURTAIN REFRIGERATOR  | 10

DX186140051  Accumulator 5/8 Suct.
DX160025190  Push handle assembly
DX186140245  Blade, fan evaporator
DX186020031  Boot, toggle switch
DX290340050  Breaker strip, grey
DXTSBP6F 

Fixed 6" Performa

DX183016218  Swivel 6" Performa with *side* brake
DX186140276  Evaporator coil, #5598
DX186140403  Evaporator coil, #6759
DX186125050  Condensing unit R134a 1/2 HP
DX186125036  Condensing unit R134a, 1/3 HP
DX186140097  Condensate evaporator 120v
DX186050017  Cord with plug 14/3 HSJO, 5-20P
DX165046269  Evaporator cover
DX160061244  Stainless steel door
DX186140062  Filter drier C-052-S
DX170202175  Door gasket
DX165046205  Front grill
DX183030080  SST Flush pull handle
DX160904097  Door hinges
DX186020089  1/2 HP relay
DX183020050  Magnetic door latch, chrome offset
DX183020048  Magnetic door latch, locking, chrome offset
DX186140242  Evaporator motor, 120v
DX183020054  Door strike, SST #R25
DX186020013  Push button door switch
DX186020030  Toggle switch, 30A
DX186160055  Digital controller
DX186160013  Digital controller probe
DX186140091  Expansion valve, 1/2 HP
DX165035504  Door hold open retainer bracket
DX183050076  Rubber door stop bumper
DX181410030  Mounting rivet for DX183050076 bumper
DX160011933  Bottom left pan slide duct
DX160011934  Top left pan slide duct
DX160011935  Bottom right pan slide duct
DX160011936  Top right pan slide duct
DX186140028  HGBP Solenoid, 120v
DX186120147  Pad Heater
DX165046204  Side vent panel
DX186140085  Expansion valve, 1/3 HP
DX186020324 Socket
DX186160135 Transformer
DX170300645  Wrap-around bumper

Summary of Contents for DXIRAC12LS

Page 1: ...e following information Model Number Serial Number Manual No IRAC12_1019_A DO NOT DISCARD 4711 E Hefner Rd 73131 PO Box 53006 Oklahoma City OK 73152 3006 800 654 8210 Fax 800 872 4701 www dinex com Ai...

Page 2: ...today Before install ing or operating our new Dinex Products equipment you should read through this material This manual should be retained for further reference as it contains installation and operat...

Page 3: ...close the door and allow inside air temperature to restabilize to 34 F 40 F The Air Curtain can maintain 34 F 40 F in excess of two hours with the doors open This performance is dependent upon the te...

Page 4: ...the set point push the up arrow or down arrow within 15 seconds 3 Push the SET1 or SET2 key again or wait 15 seconds to save the new setting To activate manual defrost The refrigerator has an automat...

Page 5: ...air inside IMPORTANT To maintain proper temperatures in the air curtain and to prolong the life of the compressor the condenser coils must be cleaned on a regular basis It is recommended that the coil...

Page 6: ...d 5 Remove the latch strike plate from the cabinet See Fig 4 and relocate it to the opposite side of the cabinet door opening 6 Mount door on the opposite side of the cabinet by removing two 2 plates...

Page 7: ...lace the air curtain next to steam tables fryers or other heat producing equipment Outside air flows such as fans and facility air ducts will greatly affect the performance of the air curtain Food pro...

Page 8: ...NESS 18603 0022 16 4 CORDAGE BLACK ELECTRICAL TAPE SHOULD BE FULLY WRAPPED AROUND COMBINED WIRES 8 AND 16 AND WIRE 2 RING CONNECTORS ALSO WIRE 16 SHOULD BE REMOVED FROM WAGO 5 POLE 2 AND TAPED WAGO 5...

Page 9: ...23 72 27720 51 66 5 9 6 5 37 21 7 33529 668 5 0 7 5 1 6 250 72 5 1 6 5 7 21 1 8 5 0 1 7 2 3 0 7 5 3 0 17 51 5 8 5 6 3 6 81 66 27 5 6 63 0 16 216 5 1 1 6 7 1 7 0 1 6 5 1 6 5 1 180 5 7 5 9 6 6 7 2 5 277...

Page 10: ...83030080 SST Flush pull handle DX160904097 Door hinges DX186020089 1 2 HP relay DX183020050 Magnetic door latch chrome offset DX183020048 Magnetic door latch locking chrome offset DX186140242 Evaporat...

Page 11: ...plies and accessories that are shipped with Warranted Products is covered by a separate warranty statement which is available at www dinex com Services Dinex warrants that any service it provides to C...

Page 12: ...pping or accident iii damage caused by improper installation repair or alteration not performed by Dinex iv the use of the Warranted Product in combination with any software tools hardware equipment s...

Page 13: ...AIR CURTAIN REFRIGERATOR 13...

Page 14: ...the right to change specifications and product design without notice Such revisions do not entitle the buyer to corresponding changes improvements additions or replacements for previously purchased eq...

Reviews: