Dinex DXIRAC12LS Operating & Maintenance Manual Download Page 1

Introduction .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Installation  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Operating Instructions .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
Maintenance  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5
Unit Specifications   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7
Wiring Diagram   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .8
Replacement Parts   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .10
Dinex® Warranty .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .11

Model:  IRAC12XX

For Service Information call 1 .888 .673 .4639

Please provide following information:

Model Number 

Serial Number 

Manual No . IRAC12_1019_A

DO NOT DISCARD

4711 E . Hefner Rd . (73131) • PO Box 53006  • Oklahoma City, OK 73152-3006
(800) 654-8210 • Fax (800) 872-4701  •  www .dinex .com                                             

Air curtain refrigerator

Operating & Maintenance Manual

Is the unit plugged-in?

Is the power switch on?
Is set temp at 34°F (3°C)

Is condenser clean? 

Has the unit been defrosted

?

Please check the following before calling service:

!

Summary of Contents for DXIRAC12LS

Page 1: ...e following information Model Number Serial Number Manual No IRAC12_1019_A DO NOT DISCARD 4711 E Hefner Rd 73131 PO Box 53006 Oklahoma City OK 73152 3006 800 654 8210 Fax 800 872 4701 www dinex com Ai...

Page 2: ...today Before install ing or operating our new Dinex Products equipment you should read through this material This manual should be retained for further reference as it contains installation and operat...

Page 3: ...close the door and allow inside air temperature to restabilize to 34 F 40 F The Air Curtain can maintain 34 F 40 F in excess of two hours with the doors open This performance is dependent upon the te...

Page 4: ...the set point push the up arrow or down arrow within 15 seconds 3 Push the SET1 or SET2 key again or wait 15 seconds to save the new setting To activate manual defrost The refrigerator has an automat...

Page 5: ...air inside IMPORTANT To maintain proper temperatures in the air curtain and to prolong the life of the compressor the condenser coils must be cleaned on a regular basis It is recommended that the coil...

Page 6: ...d 5 Remove the latch strike plate from the cabinet See Fig 4 and relocate it to the opposite side of the cabinet door opening 6 Mount door on the opposite side of the cabinet by removing two 2 plates...

Page 7: ...lace the air curtain next to steam tables fryers or other heat producing equipment Outside air flows such as fans and facility air ducts will greatly affect the performance of the air curtain Food pro...

Page 8: ...NESS 18603 0022 16 4 CORDAGE BLACK ELECTRICAL TAPE SHOULD BE FULLY WRAPPED AROUND COMBINED WIRES 8 AND 16 AND WIRE 2 RING CONNECTORS ALSO WIRE 16 SHOULD BE REMOVED FROM WAGO 5 POLE 2 AND TAPED WAGO 5...

Page 9: ...23 72 27720 51 66 5 9 6 5 37 21 7 33529 668 5 0 7 5 1 6 250 72 5 1 6 5 7 21 1 8 5 0 1 7 2 3 0 7 5 3 0 17 51 5 8 5 6 3 6 81 66 27 5 6 63 0 16 216 5 1 1 6 7 1 7 0 1 6 5 1 6 5 1 180 5 7 5 9 6 6 7 2 5 277...

Page 10: ...83030080 SST Flush pull handle DX160904097 Door hinges DX186020089 1 2 HP relay DX183020050 Magnetic door latch chrome offset DX183020048 Magnetic door latch locking chrome offset DX186140242 Evaporat...

Page 11: ...plies and accessories that are shipped with Warranted Products is covered by a separate warranty statement which is available at www dinex com Services Dinex warrants that any service it provides to C...

Page 12: ...pping or accident iii damage caused by improper installation repair or alteration not performed by Dinex iv the use of the Warranted Product in combination with any software tools hardware equipment s...

Page 13: ...AIR CURTAIN REFRIGERATOR 13...

Page 14: ...the right to change specifications and product design without notice Such revisions do not entitle the buyer to corresponding changes improvements additions or replacements for previously purchased eq...

Reviews: