HLM–35
©
Dinel, s.r.o.
12
12 . e
xamples
of
markings
for
a
Variant
with
user
settings
11 . u
ser
-
adjustaBle
measuring
ranges
For the variants of sensors with the possibility of user settings, it is possible to choose from
the ranges shown in the following table.
The above table defines the setting variances for each range for both stainless steel and ce
-
ramic transducers. The level meters with a broad range are not recommended to be used to
measure low levels. Such usage of the sensor brings a more significant measurement error
into the measuring system.
HLM–35N-CV-G3/4–I–A–M–0100 kabel 3m
(N) non-explosive areas; (CV) ceramic membrane of the sensor, pressure compensation via
semi-permeable valve; (G3/4) pipe thread G ¾; (I) current (4 ... 20 mA); (A) stainless steel
cable gland for CV and SV; (M) Settings using the magnetic pen, (0100) measuring range 10,
the maximum output current can be set in the range of 5 to 10 m see table User-adjustable
measuring ranges.
HLM–35N-SK-M27–I–B–M–0070 kabel 10m
(N) non-explosive areas; (SK) stainless steel membrane of the sensor, pressure compensa
-
tion by capillary; (M27) metric thread M 27x2; (I) current (4 ... 20 mA); (B) plastic threaded
cable gland, for CV, CK, SV and SK; (M) Settings using the magnetic pen, (0070) measuring
range 7 m, the maximum output current can be set in the range of 3,5 to 7 m, see table User-
adjustable measuring ranges.
User-adjustable measuring ranges for the M variant
Stainless steel diaphragm
Ceramic diaphragm
Measuring range
Adjustable range
of the water column [dm]
Measuring range
Adjustable range
of the water column [dm]
0010
0–10
0050
0–50
0035
10–35
0100
50–100
0070
35–70
0200
100–200
0100
70–100
0500
200–500
0250
100–250
1,000
500–1,000
0400
250–400
-
-
0600
400–600
-
-
1,000
600–1,000
-
-