background image

OPERATING INSTRUCTIONS

This storage heater  takes in Energy

when electricity tariffs are low and

dissipates it when tariffs are normal.

OPERATION

SAFETY INSTRUCTIONS

1. Ventilate rooms well during commissioning
2. Do not move the heater in any way once installed

without the services of a competent electrician.

3. Do not cover the heater with clothing etc. at any time

or position furniture close to or against the heater.

4. Ensure a clearance of at least 150mm between heaters

and curtains.

5. Should your heater fail to operate either employ the

services of a competent electrician or Telephone
(0870) 7270 101

ALSO REFER TO COVER PAGE

COMMISSIONING

Set both the Input Control and the Output Control to 6

and leave the heater for 48 hours.

Following the commissioning period adjust the

controls as stated below.

CONTROL FUNCTIONS

THE INPUT CONTROL

For models XMS712N, 718N, 724N only:

This heater is fitted with a user adjustable automatic input
control which varies the charge taken in response to weather
conditions taking into account the amount of energy already
stored in the heater.
Set at 6 the heater takes maximum charge and at 1 the heater
takes a minimum charge at any room temperature.  The casing
of the heater, particularly in late evening, may feel cool, this
is quite normal.  The input control may require a few days
experimentation before your comfort level is established.

CLEANING

To maintain the appearance of the heater wipe occasionally
with a  dry cloth when the heater is cool.
Do not use abrasive powders of furniture polish.

AFTER SALES SERVICE

Your Storage Heater is guaranteed for two years from date
of purchase.  We undertake to exchange or repair within the
period, any part found to be defective due to a manufacturing
fault.  This guarantee does not affect you statutory rights.
Should you require after sales service, please contact the
supplier through whom you purchased the heater, or telephone

(0870) 7270 101.
Please do not initially return faulty appliance, or part of an
appliance, to us as this may result in transit damage and/or a
delay in providing service.
Let us know your difficulty quoting the model number and serial
number (located along the wall bracket).  We will then take the
appropriate action.

SETTING THE CONTROLS

The controls are located under the hinged flap at the top right
hand corner of the heater.
To adjust the controls on the heater use a coin and engage it
in the slots provided on the top surface of the knob.  There
are no user adjustable controls on the XMX706N.

For models XMX712N, 718N, 724N only:

Initially set the input to 4.  If the heater does not maintain a
satisfactory room temperature the following day this setting
should be increased.  Conversely if the room temperature is

too high this setting should be reduced.
The input control should only require seasonal adjustments.

THE OUTPUT CONTROL

For all models except XMX706N

Most of the stored heat is radiated from the casing during the
discharge period.  However, some of the heater is emitted
through the grille at the top of the heater and this additional
heat (or boost) is regulated by the Output Control.

With this set to 6 the boost begins in the early afternoon.  Turning
the control towards 1 will progressively delay the commencement
of the boost.  At 3 the boost will start in the evening.  Once set,
the boost will repeat itself automatically day after day.
If no boost is required e.g. when the room will be unoccupied
for a long period, set the Output Control to 1.  With the control

in this position, the heater will take less energy during the
next charging up period.

This appliance complies with the European Standards EN 60 335-1, EN 60 335-2-61, EN 61000-3-2,
EN 61000-3-3, EN 55014 and EN55104 for Safety & Electromagnetic Compatibility.
These standards cover the requirements of the EMC Directives 89/336 & 73/23.

85149  Issue 4 : February 2006

Initially set the control to 4, the following evening if the room

is too warm reduce to 3 or if it is too cool increase to 5.  On
subsequent evenings adjust by half divisions until our comfort
level is achieved.
Having established the setting the input will automatically carry
the amount of heat stored to compensate for weather variations.

Customer Help Line

0870 7270 101

Product Sales

0870 7270 103

Head Office

0870 0777 117

e-mail

[email protected]

Glen Dimplex UK Limited,              Millbrook House,

Grange Drive,

 Hedge End,

Southampton,

 SO30 2DF.

Discolouration of wall finishes can sometimes occur immediately
above a storage heater due to the properties of some paints and

decorating materials or the presence of environmental impurities
in the air (such as soot or incense generated from the burning of
candles, etc.)

© 

Glen Dimplex UK Limited

All rights reserved. Material contained in this publication may not be reproduced in whole or part, without prior permission in writing from Glen Dimplex UK Limited.

Summary of Contents for XMX706N

Page 1: ...ith the heater does not occur Ê WHERE YOUNG CHILDREN INFIRM PERSONS OR THE AGED ARE PRESENT THIS APPLIANCE MUST BE ADEQUATELY GUARDED Contact your installer or the manufacturer for further advice Ê This appliance is very heavy and must be securely fixed to a wall DO NOT UNDER ANY CIRCUMSTANCES ATTEMPT TO MOVE OR REPOSITION THIS HEATER WITHOUT SEEKING EXPERT ADVICE Ê To maintain stability it is ess...

Page 2: ...level surface at least 75mm from any end wall and at least 250mm below any shelf or similar projection Cut away any gripper rod or carpet which would prevent the heater sitting firmly on the floor 4 4 Mark the position of the two outside corners of the wall bracket with the heater pushed tight against the wall Remove the wall bracket from the heater by removing the screw at each end Place the heat...

Page 3: ...ent up and out of the heater Carefully fit the bottom row of the back layer of bricks placing the two end bricks in position first with the recess towards the element Fit the top row of bricks also with the recess towards the element 11 Refit the element which has been removed by feeding the tails down through the hole in the base insulation and into the connector block Ensure the element is fully...

Page 4: ... of the heater To adjust the controls on the heater use a coin and engage it in the slots provided on the top surface of the knob There are no user adjustable controls on the XMX706N For models XMX712N 718N 724N only Initially set the input to 4 If the heater does not maintain a satisfactory room temperature the following day this setting should be increased Conversely if the room temperature is t...

Reviews: