OPERATING INSTRUCTIONS
This storage heater takes in Energy
when electricity tariffs are low and
dissipates it when tariffs are normal.
OPERATION
SAFETY INSTRUCTIONS
1. Ventilate rooms well during commissioning
2. Do not move the heater in any way once installed
without the services of a competent electrician.
3. Do not cover the heater with clothing etc. at any time
or position furniture close to or against the heater.
4. Ensure a clearance of at least 150mm between heaters
and curtains.
5. Should your heater fail to operate either employ the
services of a competent electrician or Telephone
(0870) 7270 101
ALSO REFER TO COVER PAGE
COMMISSIONING
Set both the Input Control and the Output Control to 6
and leave the heater for 48 hours.
Following the commissioning period adjust the
controls as stated below.
CONTROL FUNCTIONS
THE INPUT CONTROL
For models XMS712N, 718N, 724N only:
This heater is fitted with a user adjustable automatic input
control which varies the charge taken in response to weather
conditions taking into account the amount of energy already
stored in the heater.
Set at 6 the heater takes maximum charge and at 1 the heater
takes a minimum charge at any room temperature. The casing
of the heater, particularly in late evening, may feel cool, this
is quite normal. The input control may require a few days
experimentation before your comfort level is established.
CLEANING
To maintain the appearance of the heater wipe occasionally
with a dry cloth when the heater is cool.
Do not use abrasive powders of furniture polish.
AFTER SALES SERVICE
Your Storage Heater is guaranteed for two years from date
of purchase. We undertake to exchange or repair within the
period, any part found to be defective due to a manufacturing
fault. This guarantee does not affect you statutory rights.
Should you require after sales service, please contact the
supplier through whom you purchased the heater, or telephone
(0870) 7270 101.
Please do not initially return faulty appliance, or part of an
appliance, to us as this may result in transit damage and/or a
delay in providing service.
Let us know your difficulty quoting the model number and serial
number (located along the wall bracket). We will then take the
appropriate action.
SETTING THE CONTROLS
The controls are located under the hinged flap at the top right
hand corner of the heater.
To adjust the controls on the heater use a coin and engage it
in the slots provided on the top surface of the knob. There
are no user adjustable controls on the XMX706N.
For models XMX712N, 718N, 724N only:
Initially set the input to 4. If the heater does not maintain a
satisfactory room temperature the following day this setting
should be increased. Conversely if the room temperature is
too high this setting should be reduced.
The input control should only require seasonal adjustments.
THE OUTPUT CONTROL
For all models except XMX706N
Most of the stored heat is radiated from the casing during the
discharge period. However, some of the heater is emitted
through the grille at the top of the heater and this additional
heat (or boost) is regulated by the Output Control.
With this set to 6 the boost begins in the early afternoon. Turning
the control towards 1 will progressively delay the commencement
of the boost. At 3 the boost will start in the evening. Once set,
the boost will repeat itself automatically day after day.
If no boost is required e.g. when the room will be unoccupied
for a long period, set the Output Control to 1. With the control
in this position, the heater will take less energy during the
next charging up period.
This appliance complies with the European Standards EN 60 335-1, EN 60 335-2-61, EN 61000-3-2,
EN 61000-3-3, EN 55014 and EN55104 for Safety & Electromagnetic Compatibility.
These standards cover the requirements of the EMC Directives 89/336 & 73/23.
85149 Issue 4 : February 2006
Initially set the control to 4, the following evening if the room
is too warm reduce to 3 or if it is too cool increase to 5. On
subsequent evenings adjust by half divisions until our comfort
level is achieved.
Having established the setting the input will automatically carry
the amount of heat stored to compensate for weather variations.
Customer Help Line
0870 7270 101
Product Sales
0870 7270 103
Head Office
0870 0777 117
Glen Dimplex UK Limited, Millbrook House,
Grange Drive,
Hedge End,
Southampton,
SO30 2DF.
Discolouration of wall finishes can sometimes occur immediately
above a storage heater due to the properties of some paints and
decorating materials or the presence of environmental impurities
in the air (such as soot or incense generated from the burning of
candles, etc.)
©
Glen Dimplex UK Limited
All rights reserved. Material contained in this publication may not be reproduced in whole or part, without prior permission in writing from Glen Dimplex UK Limited.