background image

INSTALLATION INSTRUCTIONS

PREPARATION

The heater will arrive
separately from its
storage bricks, the
following bricks will
be required:

Model 706N - 4 bricks
Model 712N - 8 bricks
Model 718N - 12 bricks
Model 724N - 16 bricks

Only heat resisting cable (min. rating T85) should be
used.  The wires in the mains cable will be coloured as
follows:-

GREEN & YELLOW

-

EARTH

BLUE

-

NEUTRAL

BROWN

-

LIVE

SUGGESTED FIXINGS

SOLID BRICK/BLOCK:  

No. 10 Rawlplug fibre inserts,

5.5mm drill bit.  Drill hole 6mm deeper than rawlplug
length.

PLASTERBOARD 

- If possible locate studding and use

No. 10 woodscrews directly into the wood, otherwise
M5 rawlplug intersets are suitable.

NOTE: FOR OTHER WALL TYPES 

(e.g. Timber frame

and hollow concrete) 

SEEK SPECIALIST ADVICE.

FIXING ASSEMBLY

ENSURE THAT FIXING KIT AND FEET HAVE BEEN
LOCATED BEFORE DISPOSING OF PACKAGING.

Fit the feet with the open end of the foot to the front of

the heater.  Secure each foot using two taptite screws

provided.

1.

2.

2.

3.

Place the heater on its feet and in the desired position

against the wall.  Ensure the heater is based on a firm

level surface at least 75mm from any end wall and at least

250mm below any shelf or similar projection.  Cut away any

gripper rod or carpet which would prevent the heater sitting

firmly on the floor.

4.

4.

Mark the position of the two outside corners of the wall

bracket with the heater pushed tight against the wall.

Remove the wall bracket from the heater by removing the

screw at each end.  Place the heater to one side and reposition

the bracket against the wall using the corner marks for

alignment.
Four fixing positions must be chosen for the 724N, three for

the 718N and two for the 712N and 706N.  Mark the positions

for the fixing holes - two at the extreme ends and the others

spaced evenly between them.  Remove the bracket from the

wall, drill the holes in the positions marked, and insert suitable

fixings previously described.  Secure the wall bracket to the

wall.

5.

5.

If mains connection is to be made from the left side, at

this point the mains lead must be secured to the back of

the heater using ties provided in the fixing kit.

6.

6.

XMS MODELS ONLY - 

The Room Sensor is located at

the rear of the right hand side of the heater.  Carefully

slide the sensor plate down from its transit position to its

operational position.

3.

WARNING

 - This appliance must be earthed

Summary of Contents for XMX706N

Page 1: ...ith the heater does not occur Ê WHERE YOUNG CHILDREN INFIRM PERSONS OR THE AGED ARE PRESENT THIS APPLIANCE MUST BE ADEQUATELY GUARDED Contact your installer or the manufacturer for further advice Ê This appliance is very heavy and must be securely fixed to a wall DO NOT UNDER ANY CIRCUMSTANCES ATTEMPT TO MOVE OR REPOSITION THIS HEATER WITHOUT SEEKING EXPERT ADVICE Ê To maintain stability it is ess...

Page 2: ...level surface at least 75mm from any end wall and at least 250mm below any shelf or similar projection Cut away any gripper rod or carpet which would prevent the heater sitting firmly on the floor 4 4 Mark the position of the two outside corners of the wall bracket with the heater pushed tight against the wall Remove the wall bracket from the heater by removing the screw at each end Place the heat...

Page 3: ...ent up and out of the heater Carefully fit the bottom row of the back layer of bricks placing the two end bricks in position first with the recess towards the element Fit the top row of bricks also with the recess towards the element 11 Refit the element which has been removed by feeding the tails down through the hole in the base insulation and into the connector block Ensure the element is fully...

Page 4: ... of the heater To adjust the controls on the heater use a coin and engage it in the slots provided on the top surface of the knob There are no user adjustable controls on the XMX706N For models XMX712N 718N 724N only Initially set the input to 4 If the heater does not maintain a satisfactory room temperature the following day this setting should be increased Conversely if the room temperature is t...

Reviews: