background image

XMS(N)

 

AUTOMATIC

 

XMX(N)

 

MANUAL

STORAGE HEATER RANGE

MODELS: XMX706N

- 6kWh

XMS/X712N

- 12kWh

XMS/X718N

- 18kWh

XMS/X724N

- 24kWh

INSTALLATION

 

 

AND

 

 

OPERATING

INSTRUCTIONS

IMPORTANT

PLEASE READ THIS LEAFLET CAREFULLY AND  RETAIN FOR FURTHER USE.

NOTE ALSO THE INFORMATION GIVEN ON THE HEATER

Ê

The Installation must be carried out by trained personnel.

Ê

A means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.

Ê

The heater must not be installed immediately below a socket outlet.

Ê

The heater is not suitable for connection to a 30A ring circuit.

Ê

Do not position the heater under windows where curtains can contact the heater casing.

Ê

WARNING - THE SURFACES ON THIS HEATER CAN BE HOT.

Ê

This heater meets EN60-335 safety requirements.  However, any heater type becomes hot in normal
operation.  Care must be taken to ensure that prolonged skin contact with the heater does not occur.

Ê

WHERE YOUNG CHILDREN, INFIRM PERSONS, OR THE AGED ARE PRESENT THIS APPLIANCE
MUST BE ADEQUATELY GUARDED. Contact your installer or the manufacturer for further advice.

Ê

This appliance is very heavy and must be securely fixed to a wall.  DO NOT UNDER ANY
CIRCUMSTANCES ATTEMPT TO MOVE OR REPOSITION THIS HEATER WITHOUT SEEKING
EXPERT ADVICE.

Ê

To maintain stability, it is essential that the heater is placed on a level surface.

Ê

This heater must be installed where it is impossible for switches and other controls to be touched by a
person in a bath or shower.

Ê

IMPORTANT - Due to the newness of materials the heater will produce a slight smell for the first few
days of operation.  ROOMS MUST BE WELL VENTILATED AND YOUNG CHILDREN, CAGED BIRDS,
OR PERSONS WITH RESPIRATORY COMPLAINTS MUST NOT REMAIN IN CLOSE PROXIMITY
TO THE HEATER DURING THE FIRST 48 HOURS OF THE COMMISSIONING PERIOD.

Ê

IF, DURING ANY REASSEMBLY OF THE HEATER, A PART OF THE THERMAL INSULATION
SHOWS DAMAGE OR DETERIORATION WHICH MAY IMPAIR SAFETY, IT SHOULD BE REPLACED
BY AN IDENTICAL PART.

Summary of Contents for XMX706N

Page 1: ...ith the heater does not occur Ê WHERE YOUNG CHILDREN INFIRM PERSONS OR THE AGED ARE PRESENT THIS APPLIANCE MUST BE ADEQUATELY GUARDED Contact your installer or the manufacturer for further advice Ê This appliance is very heavy and must be securely fixed to a wall DO NOT UNDER ANY CIRCUMSTANCES ATTEMPT TO MOVE OR REPOSITION THIS HEATER WITHOUT SEEKING EXPERT ADVICE Ê To maintain stability it is ess...

Page 2: ...level surface at least 75mm from any end wall and at least 250mm below any shelf or similar projection Cut away any gripper rod or carpet which would prevent the heater sitting firmly on the floor 4 4 Mark the position of the two outside corners of the wall bracket with the heater pushed tight against the wall Remove the wall bracket from the heater by removing the screw at each end Place the heat...

Page 3: ...ent up and out of the heater Carefully fit the bottom row of the back layer of bricks placing the two end bricks in position first with the recess towards the element Fit the top row of bricks also with the recess towards the element 11 Refit the element which has been removed by feeding the tails down through the hole in the base insulation and into the connector block Ensure the element is fully...

Page 4: ... of the heater To adjust the controls on the heater use a coin and engage it in the slots provided on the top surface of the knob There are no user adjustable controls on the XMX706N For models XMX712N 718N 724N only Initially set the input to 4 If the heater does not maintain a satisfactory room temperature the following day this setting should be increased Conversely if the room temperature is t...