EN-12 452231.66.10 · FD 9311
www.dimplex.de
English
SIK 7TE - SIK 14TE
7
Complies with the European safety regulations
4
4
4
4
8
Additional model features
8.1
Water in device is protected against freezing
5
Yes
Yes
Yes
Yes
8.2
Max. operating overpressure (heat source/heat sink)
bar
3,0
3,0
3,0
3,0
9
Heat output / COP
9.1
Heat output / COP
3
EN 14511
EN 14511
EN 14511
EN 14511
at B-5 / W45
kW / ---
5,6 / 2,8
7,1 / 2,7
9,6 / 2,9
11,6 / 2,9
at B0 / W55
kW / ---
6,3 / 2,6
8,3 / 2,7
10,6 / 2,7
13,1 / 2,8
at B0 / W45
kW / ---
6,6 / 3,1
8,7 / 3,3
11,2 / 3,3
14,1 / 3,6
at B0 / W35
kW / ---
6,8 / 4,3
9,0 / 4,3
11,7 / 4,4
14,4 / 4,4
1. The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of 35 °C.
The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
2. Please note that additional space is required for pipe connections, operation and maintenance.
3. These data indicate the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, the bivalence point and
regulation should be taken into consideration. These specifications can only be achieved with clean heat exchangers. Information on maintenance, commissioning and operation
can be found in the respective sections of the installation and operating instructions. The specified values have the following meaning, e.g. B0 / W35: Heat source temperature 0 °C
and heating water flow temperature 35 °C.
4. See CE declaration of conformity
5. The heat circulating pump and the heat pump manager must always be ready for operation.