E-10
English
12
12 Device Information
1
Type and order code
SIK 7TE-2
SIK 9TE-2
SIK 11TE-2
SIK 14TE-2
2
Design
2.1
Model
Compact
Compact
Compact
Compact
2.2
Controller
Internal
Internal
Internal
Internal
2.3
Thermal energy meter
Integrated
Integrated
Integrated
Integrated
2.4
Installation location / degree of protection according to EN 60 529
Indoors / IP 20
Indoors / IP 20
Indoors / IP 20
Indoors / IP 20
2.5
Performance levels
1
1
1
1
3
Performance data
1
3.1
Operating temperature limits:
Heating water flow
°C
20 up to 58 ± 2
20 up to 58 ± 2
20 up to 58 ± 2
20 up to 58 ± 2
Brine (heat source)
°C
-5 to +25
-5 to +25
-5 to +25
-5 to +25
Antifreeze
Monoethylene
glycol
Monoethylene
glycol
Monoethylene
glycol
Monoethylene
glycol
Minimum brine concentration (-13 °C freezing temperature)
25%
25%
25%
25%
3.2
Temperature spread of heating waterat B0 / W35
K
9.9
5.0
10.5
5.0
10.1
5.0
9.6
5.0
3.3
Heat output / COP
at B5 / W55
kW / ---
5.6 /
2.2
7.7 /
2.3
9.4 /
2.4
12.5 /
2.6
at B0 / W45
kW / ---
6.6 /
3.0
8.7 /
3.2
11.2 /
3.2
14.1 /
3.5
at B0 / W50
kW / ---
6.7 /
2.9
9.0 /
3.1
11.3 /
3.0
14.2 /
3.4
at B0 / W35
kW / ---
6.9 /
4.3
6.8 /
4.1
9.2 /
4.4
9.0 /
4.2
11.8 /
4.4
11.7 /
4.2
14.5 /
4.5
14.4 /
4.3
3.4
Sound power level EN 12102
dB(A)
51
51
51
51
3.5
Sound pressure level at a distance of 1m
2
dB(A)
40
40
40
40
3.6
Heating water flow rate with an
internal pressure differential of
m³/h / Pa
0.6 /
2600
1.2 /
12000
0.75 /
4700
1.6 /
21000
1.0 /
3600
2.0 /
15000
1.3 /
3600
2.5 /
16700
3.7
Free compression of heat circulating pump (max. level) Pa
64400
54000
62300
43000
63400
44000
62400
33300
3.8
Brine flow with an internal pressure differential
(heat source) of
m³/h / Pa
1.7 /
10200
1.6 /
9500
2.3 /
16300
2.2 /
15300
3.0 /
13300
2.7 /
11600
3.5 /
13300
3.3 /
11800
3.9
Free compression of brine circulating pump (max. level) Pa
54800
56000
43700
45700
39700
44400
33700
38200
3.10 Refrigerant; total filling weight
type / kg
R407C / 1.5
R407C / 1.8
R407C / 2.0
R407C / 2.3
3.11 Lubricant; total filling quantity
type / litres
Polyolester
(POE) / 1.0
Polyolester
(POE) / 1.1
Polyolester
(POE) / 1.36
Polyolester
(POE) / 1.95
3.12 Electrical pipe heater (2nd heat generator)
kW
2
3
. 4 or 6
2
3
. 4 or 6
2
3
. 4 or 6
2
3
. 4 or 6
4
Dimensions, connections and weight
4.1
Device dimensions without connections
4
H x W x L mm
1115
652
688 1115
652
688 1115
652
688 1115
652
688
4.2
Device connections for heating system
Inch
G 1¼" external
G 1¼" external
G 1¼" external
G 1¼" external
4.3
Device connections for heat source
Inches
G 1¼" external
G 1¼" external
G 1¼" external
G 1¼" external
4.4
Weight of the transport unit(s) incl. packaging
kg
179
180
191
203
5
Electrical connection
5.1
Control voltage / fuse protection
1~/N/PE 230V
(50Hz) / C13A
1~/N/PE 230V
(50Hz) / C13A
1~/N/PE 230V
(50Hz) / C13A
1~/N/PE 230V
(50Hz) / C13A
5.2
Supply voltage / fuse protection for combined infeed:
3~/N/PE 400V
(50Hz) / C20A
3~/PE 400V
(50Hz) / C20A
3~/PE 400V
(50Hz) / C20A
3~/N/PE 400V
(50Hz) / C20A
5.3
Supply voltage / fuse protection for separate infeed:
Heat pump
3~/PE 400V
(50Hz) / C10A
3~/PE 400V
(50Hz) / C13A
3~/PE 400V
(50Hz) / C13A
3~/PE 400V
(50Hz) / C13A
2nd heat generator
3~/N/PE 400V
(50Hz) / B10A
3~/N/PE 400V
(50Hz) / B10A
3~/N/PE 400V
(50Hz) / B10A
3~/N/PE 400V
(50Hz) / B10A
5.4
Nominal power consumption
1
B0 W35
kW
1.6
1.66
2.09
2.14
2.68
2.79
3.22
3.35
5.5
Starting current with soft starter
A
30 (without SS)
18
19
24
5.6
Nominal current
1
B0 W35 / cos
A / ---
2.89 /
0.8
3,00 /
0.8
3.77 /
0.8
3.86 /
0.8
4.84 /
0.8
5.03 /
0.8
5.81 /
0.8
6.04 /
0.8
Summary of Contents for SIK 11 TE-2
Page 2: ......
Page 26: ...E 12 English 12 ...
Page 46: ...A VIII Anhang Appendix Annexes 3 2 3 2 Steuerung Control Commande ...
Page 48: ...A X Anhang Appendix Annexes 3 4 3 4 Anschlussplan Circuit Diagram Schéma électrique ...
Page 57: ...www dimplex de A XIX Anhang Appendix Annexes 5 ...
Page 58: ...A XX Anhang Appendix Annexes 5 ...
Page 59: ...www dimplex de A XXI Anhang Appendix Annexes 5 ...