www.dimplex.de 452234.66.02 · FD 9311
EN11
English
SI 50TE - SI 130TE
12 Equipment Data
1
Type and order code
SI 50TE
SI 75TE
SI 100TE
SI 130TE
2
Design
2.1
Controller
Internal
Internal
Internal
Internal
2.2
Installation location / degree of protection according to EN 60 529
Indoors / IP 21
Indoors / IP 21
Indoors / IP 21
Indoors / IP 21
2.3
Performance levels
2
2
2
2
3
Operating limits
3.1
Heating water flow
°C
20 to 58 ± 2
Brine (heat source)
°C
-5 to +25
Antifreeze
Monoethylene glycol
Minimum brine concentration (-13 °C freezing temperature)
25%
25%
25%
25%
4
Performance data / flow rate
1
1. This data indicates the size and capacity of the system according to EN 14511 (5K at B0/W35). For an analysis of the economic and energy efficiency of the system, both the
bivalence point and the regulation should be taken into consideration. These specifications can only be achieved with clean heat exchangers. Information on maintenance, start-
up and operation can be found in the respective sections of the installation and operating instructions. The specified values, e.g. B10 / W55, have the following meaning: Heat
source temperature 10 °C and heating water flow temperature 55 °C.
4.1
Heating water flow rate / internal pressure differential
maximum
m³/h / Pa
7.8 / 6400
12.5 / 8500
16.3 / 14200
21.0 / 7100
minimum
m³/h / Pa
3.6 / 1400
5.6 / 1700
7.6 / 3100
9.6 / 1500
4.2
Heat output / COP
2
2. At maximum heating water flow rate
EN 14511
EN 14511
EN 14511
EN 14511
at B-5 / W45
kW / ---
3
3. Operation with 2 compressors
38.0 / 2.8
59.7 / 2.8
77.9 / 3.0
99.0 / 2.7
kW / ---
4
4. Operation with 1 compressor
17.1 / 2.6
30.6 / 2.7
41.4 / 2.7
43.9 / 2.6
at B0 / W55
kW / ---
3
41.3 / 2.5
61.9 / 2.4
85.1 / 2.7
102.6 / 2.4
kW / ---
4
19.4 / 2.4
31.9 / 2.4
36.1 / 2.3
45.9 / 2.4
at B0 / W45
kW / ---
3
43.4 / 3.3
67.3 / 3.1
88.7 / 3.3
112.9 / 3.1
kW / ---
4
21.6 / 3.2
34.4 / 3.1
42.0 / 3.2
53.6 / 3.1
at B0 / W35
kW / ---
3
45.8 / 4.3
72.7 / 4.2
92.3 / 4.4
122.0 / 4.1
kW / ---
4
23.2 / 4.3
36.1 / 4.1
46.3 / 4.3
60.8 / 4.1
4.3
Sound power level according to EN 12102
dB(A)
57
63
65
67
4.4
Sound pressure level at a distance of 1m
5
dB(A)
5. The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of 35 °C. The specified sound pressure level
represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
49
53
54
55
4.5
Brine flow with an internal pressure differential (heat source) of m³/h / Pa
11.1 / 13400
19.6 / 16700
21.5 / 19500
34.0 / 26200
4.6
Refrigerant / total filling weight
type / kg
R404A / 8.6
R404A / 14.1
R404A / 20.5
R404A / 27.0
4.7
Lubricant / total filling quantity
type / litres
Polyolester
(POE) / 6.5
Polyolester
(POE) / 6.5
Polyolester
(POE) / 13.2
Polyolester
(POE) / 16.0
5
Dimensions, connections and weight
5.1
Device dimensions without connections
6
H x W x L mm
6. Note that additional space is required for pipe connections, operation and maintenance.
1890 x 1350 x 775
5.2
Device connections for heating system
Inches
G 1 1/2'' internal/
external
G 2'' internal/
external
G 2'' internal/
external
G 2 1/2'' internal/
external
5.3
Device connections for heat source
Inches
G 2 1/2'' internal/
external
G 2 1/2'' internal/
external
G 3'' internal/
external
G 3'' internal/
external
5.4
Weight of the transportable unit(s) incl. packaging
kg
486
571
652
860
6
Electrical connection
6.1
Supply voltage; fuse protection
3~/PE 400 V
(50 Hz) / C 50A
3~/PE 400 V
(50 Hz) / C +63A
3~/PE 400 V
(50 Hz) / C 80A
3~/PE 400 V
(50 Hz) / C 80A
6.2
Control voltage / fuse protection
1~/N/PE 230 V (50 Hz) / C 13A
6.3
Nominal power consumption B0 W35
3
/ max. power consumption
1
kW
10.65 / 17.0
17.31 / 30.0
20.98 / 36.0
29.76 / 45.0
6.4
Starting current with soft starter
A
63
105
120
115
6.5
Nominal current B0 W35 / cos
3
A / ---
19.21 / 0.8
31.23 / 0.8
37.85 / 0.8
53.69 / 0.8
6.6
Max. power consumption of compressor protection
(per compressor)
W
65
65
75
130
7
Complies with the European safety regulations
7
7. See CE declaration of conformity
7
7
7
8
Additional model features
8.1
Water in device is protected against freezing
8
8. The heat circulating pump and the heat pump manager must always be ready for operation.
Yes
Yes
Yes
Yes
8.2
Max. operating overpressure (heat source/heat sink) bar
3.0
3.0
3.0
3.0
Summary of Contents for SI 100TE
Page 2: ......
Page 26: ...EN 12 452234 66 02 FD 9311 www dimplex de English SI 50TE SI 130TE ...
Page 38: ...FR 12 452234 66 02 FD 9311 www dimplex de Français SI 50TE SI 130TE ...
Page 69: ...www dimplex de 452234 66 02 FD 9311 A XXXI Anhang Appendix Annexes SI 50TE SI 130TE ...
Page 70: ...A XXXII 452234 66 02 FD 9311 Anhang Appendix Annexes SI 50TE SI 130TE ...
Page 71: ...www dimplex de 452234 66 02 FD 9311 A XXXIII Anhang Appendix Annexes SI 50TE SI 130TE ...