background image

2.          The location of the control is important, it will not function 

correctly if above or within 500mm of a heat source or 
draught. Care must also be taken not to obscure the slots at 
the top or bottom of the control and that it is not exposed to 
direct bright sunlight or close to a lamp fitting. Best 
temperature accuracy will be achieved by mounting on an 
internal wall or partition. 

3.          The pattress boxes (not provided) should have a depth of at 

least 25mm. Plastic pattress boxes with vertical pillars are not 
suitable. 

            Vertical tabs in metal pattress boxes should be removed. 
            Ensure all entries into the pattress boxes are sealed to 
            prevent draughts. 

4.          Before fitting to the mounting box setback temperature, 

            comfort temperature and comfort period must be selected. To 
            do this, adjust the appropriate dial on the reverse of the PCB. 

5.          The supply cable is not provided and should therefore be 

selected to suit the appliance.  

            Warning: Although the control does not need an earth, the 

appliance probably does. Ensure that the mounting box is 
fitted with an earth terminal for earth continuity to the 
appliance. 

6.          To connect the control in circuit wire in to the clearly marked 

terminal block on the rear of the controller. The control must 
only be connected via fixed wiring. 

7.          Secure the control to the pattress box such that there are no 

            gaps between the controller and wall or pattress box. 

Note: If tamperproof screws are required they should be M3 x 40mm 
long, counter sunk with a head diameter of no more than 6.5mm. 

Installation and 
Operating Instructions 

Press Button Delay Timer  - Model No. PX01001 

Safety Warnings

 

1.          WARNING: DO NOT USE THIS APPLIANCE IN THE  

            IMMEDIATE SURROUNDINGS OF A BATH, A SHOWER 
            OR SWIMMING POOL 

2.          WARNING: DO NOT USE WHERE EXCESSIVE DUST OR 

            MOISTURE IS PRESENT 

3.          WARNING: FOR USE IN NORMAL POLLUTION 

            SITUATIONS ONLY 

General Description

 

The PX01001 timer/thermostat can be used in conjunction with 
heating appliances. They may be flush or surface mounted using a 
standard 25mm box. The control is rated at 16A (250VAC) and  can 
be used in conjunction with heating appliances with a maximum total 
input of 13 A resistive L.C. 230V - 50Hz. The controller cannot be 
used with a Quartz heater without a suitable in-line contactor. 
Control action: Type 1B 

Operating Instructions 

The PX01001 controls the room temperature by interrupting the 
power supply to the appliance, therefore the appliance should 
always be switched on and its thermostat set to maximum 
temperature. Note this will not be reached if the pre-determined 
maximum level is below that of the appliance thermostat setting. 

    When the comfort mode is activated by pressing the 
    centre of the control face, the green light illuminates. 

                  The comfort mode allows the room to be heated to a pre-
                  determined temperature for a pre-determined time 
                  period. 

           The red light indicates that the heater is operating.  
           Note that the heater will remain on for a minimum of 1    

                  minute.  
                   
                  The red light may also be illuminated in the set back 
                  mode when the PX01001 switches the heater on to 
                  maintain the predetermined background temperature. 

Installation

 

Before undertaking installation work, ensure the electricity supply is 
disconnected from any relevant fixed wiring. 

1.          The control and heater should be installed in compliance with  

            the IEE Wiring Regulations 

comfort 
control 

Dimplex 

TOUCH 

85mm 

85mm

25mm 

boost 

Main Dimensions

 

boost 

Ensure 500mm clearance from any heat source or draught.

 

T0105/004/A 