background image

Continuous Heat Modes

Other Functions

A Continuous Heat mode is eff ectively a constant 

Heating On

 period. The Heater will remain in a Continuous Heat 

mode indefi nitely until the mode is changed by the User.

Available Continuous Heat Modes

Each continuous heat profi le ships with a default Target Temperature value.

• Manual

 

•  Default 21°C

 

•   Can be changed from the Home Screen to any value within the range 19-30°C

• Eco 

 

•  Default 18°C

 

•  Eco mode temperature can be set in the range 8-18°C

• Frost Protection

 

•  Default 7°C

 

•  Not User Defi nable

ADVANCE

MENU

BACK

ENTER

Modes

Timer Mode

Manual

Eco Mode

Frost Protect

ADVANCE

MENU

BACK

ENTER

Manual

21

°

C

Heating ON

These functions modify the normal behaviour of the heater. They don’t switch the Heater out of a Timer or Continuous 

Heat Mode, but can override/delay those operations, or restrict access to them.

The ‘Boost’ Function

Boost can be activated at any time, when the product is set to any Timer or Continuous heat mode; even if 

Advance

 is 

active This mode will provide a temporary ‘Boost’ of heat. For settings, see Boost settings on page 21.

Boost Mode can be activated from the Home Screen by pressing 

Menu

 to access the Main Menu, then pressing 

Enter

 

to select ‘

Boost

’.

16

Summary of Contents for MFP 100E

Page 1: ...Monterey MFPE Models MFP050E MFP075E MFP100E MFP150E MFP200E These instructions should be read carefully and retained for future use Note also the information presented on the appliance INSTRUCTION MA...

Page 2: ...ire risk NEVER cover or obstruct in any way the heat outlet slots at the top of the heater or the air inlet slots in the base of the heater WARNING THE SURFACES ON THIS HEATER CAN BE HOT The heater ca...

Page 3: ...rs combined with the convection effect of electric heaters can cause significant soot deposits to build up on the surface directly above and to the sides of the heater This is not a fault of the heate...

Page 4: ...iring of the premises through a suitable connection box positioned adjacent to the heater A means for disconnection must be incorporated in the fixed wiring of the premises in accordance with the curr...

Page 5: ...g and user maintenance shall not be made by children without supervision Children of less than 3 years should be kept away unless continuously supervised Children aged from 3 years and less than 8 yea...

Page 6: ...inal heat output Pnom 0 5kW 0 75kW 1 kW 1 5kW 2 0kW Height mm 536 536 536 536 536 Width mm 503 503 671 741 911 Depth mm 104 104 104 104 104 Minimum heat output indicative Pmin N A N A N A N A N A Maxi...

Page 7: ...vered upward facing grille Advanced controls with capacitive sense technology for total exibility of heating Colour Finish Metal Chassis Air Outlet Grille Control Moulding Traffic White RAL 9016 Eleme...

Page 8: ...ame as that stated on the heater MODEL A B C D E MFP050E 390mm 150mm 503mm 536mm 104mm MFP075E 390mm 150mm 503mm 536mm 104mm MFP100E 560mm 150mm 671mm 536mm 104mm MFP150E 630mm 150mm 741mm 536mm 104mm...

Page 9: ...es Ensure only screw fittings suitable for the particular wall type are used 3 Present the heater to the wall bracket and engage bottom slots in the back with bracket hooks 4 Press the top of the heat...

Page 10: ...ar after a short period of use It is however advisable to keep the room well ventilated The controls are located on top of the heater This consists of a display screen and six touch sensitive buttons...

Page 11: ...currently active mode of operation is displayed at the top of the screen e g Out All Day timer When the heater is trying to achieve or maintain a room temperature Heating On will be displayed otherwi...

Page 12: ...eriod when that period is active This will temporarily adjust the Target Temperature for just that instance and will not permanently modify the settings for the timer in use NOTE If Adaptive Start is...

Page 13: ...ew This option displays the timer s con guration This is handy to quickly check the timer without being able to change any values ADVANCE MENU BACK ENTER Manual 21 C Heating ON Period 1 Period 2 Perio...

Page 14: ...ave time when modifying a Timer Mode the Advance button can be used to copy and paste settings Individual heating periods from one day or every heating period from a day can be copied to another day C...

Page 15: ...s are set separately on the heater making the feature useful for popping out to the shops or going away on holiday The date set is the return date therefore Away mode will end at 23 59 of the day befo...

Page 16: ...t 7 C Not User De nable ADVANCE MENU BACK ENTER Modes Timer Mode Manual Eco Mode Frost Protect ADVANCE MENU BACK ENTER Manual 21 C Heating ON These functions modify the normal behaviour of the heater...

Page 17: ...The Advance Function The Advance button is only used when a Timer Mode is active and allows the timer schedule to be changed temporarily This button allows a Heating On period to begin or end early T...

Page 18: ...ter s controller by pressing and holding the Back and Enter buttons for three seconds It is a full Product lock with no exception rules PIN Lock In PIN Lock all UI buttons other than the Menu button a...

Page 19: ...y it would if the UI was not locked only if the Heater is Locked into a Timer Mode If Advance is enabled during UI lock the Advance button will function as normal while the Heater is set to a Timer Mo...

Page 20: ...s as well as enable disable modi cation of the Boost Temperature and Boost Duration See below Boost Lock Three settings can be modi ed within this Menu Enable Disable The Boost Menu Item can be Enable...

Page 21: ...the Time Date and Daylight Savings Time settings to be modi ed Sound Audio feedback when the user presses a button can be enabled or disabled here Comms Communications This allows Wireless Connectivi...

Page 22: ...e by the start of the Heating On period For example with Adaptive Start off the Heating On time is the time that the Heater will begin to try and achieve the Target Temperature With Adaptive Start On...

Page 23: ...a Excessive temperatures FAULT_CODE_EXCESSIVEROOMTEMP_FAILURE 30 FAULT_CODE_LCD_OVERHEAT 32 FAULT_CODE_EXCESSIVEACCTEMP_FAILURE n a FAULT_CODE_FAN_FAILURE n a Internal Failures FAULT_CODE_SERIAL_COMM...

Page 24: ...and locate the battery module 2 Slide the catch and pull module from the controls 3 Remove the coin cell battery and replace 4 Slide module back in place ensuring clip is engaged 4 Battery positive si...

Page 25: ...the product on and make sure that the RF comms are enabled Comms settings will be located in the settings menu see page 21 During the initial operation some odour may be noticed due to the newness of...

Page 26: ...26...

Page 27: ...27...

Page 28: ...t prior permission in writing of Glen Dimplex Customer Helpline 0344 879 3588 www dimplex co uk Glen Dimplex Heating Ventilation Millbrook House Grange Drive Hedge End Southampton SO30 2DF This produc...