EN-12
452163.66.65 · FD 9702
www.dimplex.de
English
LA 6S-TU - LA 6S-TUR
6
Electrical connection
6.1
Supply voltage / fusing / RCD type
3~/N/PE 400 V (50 Hz) / C10 A / A
6.2
Control voltage / fusing via WPM
1~/N/PE 230 V (50 Hz) / 4 AT
6.3
Degree of protection according to EN 60529
IP 24
6.4
Starting current limiter
no
6.5
Rotary field monitoring
no
6.6
Starting current with soft starter
A
28
6.7
Nominal power consumption A2 / W35 / max. power consumption
kW
1,4 / 2,93
6.8
Nominal current A2 /W35 / cos
ϕ
A / ---
2,88 / 0,8
6.9
Power consumption of compressor protection (per compressor)
W
--
6.10 Power consumption fan
W
< 125
7
Complies with the European safety regulations
6
8
Additional model features
8.1
Type of defrosting
Reverse circulation
8.2
Condensate tray frost protection / water in device is protected from freezing
7
Yes
8.3
Max. operating pressure (heat source/heat sink)
bar
3,0
9
Heat output coefficient of performance (COP)
9.1
Heat output / COP
EN 14511
with A-7 / W35
kW / ---
4,0 / 2,9
with A2 / W35
kW / ---
5,1 / 3,8
with A7 / W35
kW / ---
6,4 / 4,6
with A7 / W45
kW / ---
6,1 / 3,5
with A10 / W35
kW / ---
6,7 / 4,7
10 Cooling capacity / coefficient of performance (COP)
10.1 Cooling capacity / coefficient of performance (COP)
EN 14511
with A27 / W18
kW / ---
5,5 / 3,7
with A27 / W7
kW / ---
3,7 / 2,6
with A35 / W18
kW / ---
4,9 / 2,9
with A35 / W7
kW / ---
3,6 / 2,2
1. For air temperatures between -22°C and -5°C, flow temperature increasing from 45°C to 60°C.
2. This data indicates the size and capacity of the system according to EN 14511. For an analysis of the conomic and energy efficiency of the system, other parameters, in particular
the defrosting capacity and regulation, should also be taken into consideration. These figures are only achieved with clean heat exchangers. Instructions for care, commissioning
and operation can be found in the relevant sections of the installation and operation instructions. The specified values have the following meaning, e.g. A7/W35: outside air tem-
perature 7°C and heating water flow temperature 35°C.
3. The heat output and COP is reduced by approx. 5 % in lower operation.
4. The maximum sound power level under full load can increase by up to 5 dB(A), depending on the installation location.
5. The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
6. see CE declaration of conformity
7. The heat circulating pump and the heat pump manager must always be ready for operation.