9
Heat output coefficient of performance (COP)
9.1
Heat output / COP
EN 14511
with A-7 / W35
kW / ---
4,0 / 2,9
with A2 / W35
kW / ---
5,1 / 3,8
with A7 / W35
kW / ---
6,4 / 4,6
with A7 / W45
kW / ---
6,1 / 3,5
with A10 / W35
kW / ---
6,7 / 4,7
1. For air temperatures between -22°C and -5°C, flow temperature increasing from 45°C to 60°C.
2. This data indicates the size and capacity of the system according to EN 14511. For an analysis of the conomic and energy efficiency of the system, other parameters, in particular
the defrosting capacity and regulation, should also be taken into consideration. These figures are only achieved with clean heat exchangers. Instructions for care, commissioning
and operation can be found in the relevant sections of the installation and operation instructions. The specified values have the following meaning, e.g. A7/W35: outside air tem-
perature 7°C and heating water flow temperature 35°C.
3. The heat output and COP is reduced by approx. 5 % in lower operation.
4. The maximum sound pressure level under full load can increase by up to 5 dB(A), depending on the installation location.
5. The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
6. see CE declaration of conformity
7. The heat circulating pump and the heat pump manager must always be ready for operation.
1
Type and order code
LA 6S-TUR
2
Design
Heat source
Air
2.1
Model
Reversible
2.2
Controller
WPM wall-mounted
2.3
Installation location
Outdoors
2.4
Thermal energy metering
Integrated
2.5
Performance levels
1
3
Operating limits
3.1
Heating water flow / return
1
°C
up to 60 ± 2 / from 18
3.2
Air (heating)
°C
-22 to +35
3.2
Cooling water flow
°C
+7 to +20
3.3
Air (cooling)
°C
+15 to +45
4
Flow
2
/ sound
4.1
Heating water flow / internal pressure differential
Nominal flow according to EN 14511 with A7 / W35...30
m³/h / Pa
1,15 / 12000
with A7 / W45...40
m³/h / Pa
1,08 / 10600
with A7 / W55...47
m³/h / Pa
0,66 / 4000
4.2
Minimum heating water flow rate
m³/h / Pa
0,66 / 4000
4.3
Cooling water flow rate / internal pressure differential
4.4
Nominal flow rate in accordance
with EN 14511
A35 / W18...23
m³/h / Pa
0,8 / 6000
Minimum cooling water flow rate
m³/h / Pa
0,8 / 6000
4.5
Sound power level according to EN 12102
Normal operation / reduced operation
3
4
dB(A)
56 / 52
4.6
Sound pressure level at a distance of 10 m (air outlet side)
5
Normal operation / reduced operation
dB(A)
28 / 24
4.7
Air flow
Normal operation
m³/h
2700
5
Dimensions, weight and filling quantities
5.1
Device dimensions without connections
H x W x L mm
945 x 1350 x 600
5.2
Device connections for heating
inches
G 1“ A
5.3
Weight of the transportable unit(s) incl. packaging
kg
185
5.4
Refrigerant / total filling weight
Type / kg
R410A / 3,4
5.5
GWP value / CO
2
equivalent
--- / t
2088 / 7
5.6
Refrigeration circuit hermetically sealed
yes
5.7
Lubricant / total filling weight
Type / litres
Polyolester (POE) / 0.7
5.8
Volume of heating water in device
Litres
1,9