 HPWH 300 - HPWH 300HE

1 Please read 

immediately

1.1 Important notes

ATTENTION!

Work on the domestic hot water heat pump may only be performed by
qualified personnel. Observe accident prevention regulations.

ATTENTION!

The device cover cannot be used for carrying (the cover cannot withstand
significant forces).

ATTENTION!

If devices are installed in locations with a risk of frost and are no longer
operated or will not be connected to the power for a long period (several
hours), the water must be drained from the cylinder. If this is not done,
frost may destroy the device.

ATTENTION!

The domestic hot water heat pump must only be operated when filled with
water!

ATTENTION!

Disconnect the power supply before opening the domestic hot water heat
pump; possible fan coasting must be considered!

ATTENTION!

Malfunctioning protection anodes reduce the service life of the device!
(Electrically insulated magnesium anode with selenium complying with
DIN 4753 part 6)

ATTENTION!

Work on the domestic hot water heat pump is to be performed by
qualified personnel only! Observe accident prevention regulations!

1.2 Intended use

This  device  is  only  intended  for  use  as  specified  by  the 
manufacturer.  Any  other  use  beyond  that  intended  by  the 
manufacturer  is

 

prohibited.  This  requires  the  user  to  abide  by 

the  relevant  project

 

planning  documents.  Please  refrain  from 

tampering with or alter-ing the device.

1.3 Regulations / safety 

information

NOTE

Read these installation and operating instructions before

 

commissioning!

The domestic hot water heat pump is used exclusively to
heat water for domestic use and drinking water within the
specified operating temperature limits! The heating of fluids
other than domestic water is not permitted. The installation
must take place in accordance with the Australian standard
AS/NZS 3500.4
For domestic use in Australia and New Zealand a TEMPER-
ING VALVE must be fitted by the installer.

The following are not permitted:

It is not permissible to operate the device:

The refrigerating system meets the requirements of
ISO 5149-3:2014.

The technician must ensure that the refrigerant is flushed
adequately to allow maintenance and repair work to be car-
ried out on refrigerant circuit components without risk. Re-
frigerant must be properly handled and disposed of; it must
not be released into the environment!
The refrigeration circuit is "hermetically sealed" and contains
the fluorinated refrigerant R134a with a GWP value of 1430,
incorporated in the Kyoto protocol. The refrigerant is CFC-
free, non-ozone depleting and non-combustible.

Always disconnect the power supply before carrying out any
work on the domestic hot water heat pump.

When connecting the domestic hot water heat pump to the
power supply, the relevant IEC standards and the AS 3000
must be complied with. Also observe the technical connec-
tion requirements of the electrical utility companies.

ATTENTION!

Work on the domestic hot water heat pump may only be performed by
qualified personnel.
Observe accident prevention regulations.

Persons, especially children, who are not capable of opera-
ting the device safely due to their physical, sensory or men-
tal abilities or due to their inexperience or lack of knowledge,
must not operate this device without supervision or instruc-
tion by the person in charge.
Children must be supervised to ensure that they do not play
with the device.

- Operating the pump with solvent-based, explosive or

chloric exhaust air

- The use of exhaust air containing grease, heavy dust or

adherent aerosols

- Connecting extractor hoods to the

ventilation system

- With an empty cylinder

DANGER!

Failure to operate the PTR Valve easing gear every six 

months may lead the water heater exploding.

A PTR Valve must be fitted

ATTENTION

!

Continuous water leaking from the drain may indicate 

a problem with the water heater.

ATTENTION

!

Water may drip from both the pressure relief device 

and the condensate drain. These pipes must be left 

open to the atmosphere.

Summary of Contents for HPWH 300

Page 1: ...HPWH 300 HPWH 300HE Hot Water Heat Pump for Outdoor Installation English Installation and Operating Instructions FD 9501...

Page 2: ...N 4 4 Installation EN 5 4 1 Installation location EN 5 4 2 Installation EN 5 5 Assembly EN 5 5 1 Connecting the water pipes EN 5 5 2 Connecting the condensate hose EN 6 5 3 Electrical connection EN 6...

Page 3: ...ealand a TEMPER ING VALVE must be fitted by the installer The following are not permitted It is not permissible to operate the device The refrigerating system meets the requirements of ISO 5149 3 2014...

Page 4: ...mestic hot water temperature is higher than the temperature achievable by the heat pump approx 60 C it can be raised to a max of 85 C by means of the heating element NOTE When the domestic hot water t...

Page 5: ...ts the evaporator from freezing 3 Storage and transport 3 1 General The domestic hot water heat pump should always be stored and transported packaged in an upright position without being filled with w...

Page 6: ...e must be provided as shut off facility to avoid unnecessary energy losses Circulation is enabled according to use time or requirement control The nominal pipe widths for the on site sanitary installa...

Page 7: ...If the supply cord is damaged it must be replaced by a special cord or assembly available for the manufacturer or its service agent 6 Commissioning 6 1 Domestic hot water system ATTENTION The domesti...

Page 8: ...r heat pump possible fan coasting must be considered General The domestic hot water heat pump is virtually maintenance free Furthermore a one off visual inspection for possible leaks in the water syst...

Page 9: ...4753 part 6 8 Faults troubleshooting for the user ATTENTION Work on the domestic hot water heat pump is to be performed by qualified personnel only Observe accident prevention regulations The heat pum...

Page 10: ...nection 6 1 Degree of protection IP 24 IP 24 6 2 Connection voltage 1 N PE 230 V 50 Hz 1 N PE 230 V 50 Hz 6 3 Fuse max A C16 C16 6 4 Heat pump power consumption cos A 0 8 0 8 6 5 Supplementary electri...

Page 11: ...EN 10 451903 66 18 FD 9501 www dimplex com au English HPWH 300 HPWH 300HE...

Page 12: ...drawing A II 2 Integration Diagram A III 2 1 Process circuit diagram A III 2 2 Legend A III 2 3 Hydraulic integration diagram A IV 2 4 Legend A IV 2 5 Heat Exchanger Integration Diagram for Thermal S...

Page 13: ...JHU RXWSXW 5 H WHUQDO WKUHDG HDW H FKDQJHU LQSXW 5 H WHUQDO WKUHDG LUFXODWLRQ SLSH 5 H WHUQDO WKUHDG RW ZDWHU RXWOHW FRQQHFWLRQ 5 H WHUQDO WKUHDG RQGHQVDWH KRVH LQQHQ 6HDO YDOYH OHFWULFDO KHDWLQJ HOHP...

Page 14: ...3 14 15 Compressor Evaporator Hot water cylinder with Liquifier High pressure switch Check valve Air inlet temperature sensor R1 Filter dryer Expansion valve Cylinder temperature sensor Heating elemen...

Page 15: ...ng line drain line of the valve must not be blocked 8 Circulation pump 9 Outlet No connections for second heat generator required i e no heating water flow and no heating water return flow for hot wat...

Page 16: ...egration Diagram for Thermal Solar Installation HDW H FKDQJHU HDW H FKDQJHU ORZ 5HWXUQ IORZ KHFN YDOYH 7DS 7KHUPRPHWHU URP WKH FROOHFWRU 6DIHW YDOYH QWO IWXQJ H DHUDWLRQ 3XUJH 3UHVVXUH JDXJH DWFKPHQW...

Page 17: ...A VI 451903 66 18 FD 9501 www dimplex com au Appendix HPWH 300 HPWH 300HE 3 Circuit Diagrams 3 1 Last Load...

Page 18: ...www dimplex com au 451903 66 18 FD 9501 A VII Appendix HPWH 300 HPWH 300HE 3 2 Control...

Page 19: ...essor F17 Safety temperature limiter E1 H1 Electric heater indicator lamp J1 Digital inputs outputs U 230 V J3 Analogue inputs screw terminals K1 Compressor load relay K2 Starting relay for M1 K4 Load...

Page 20: ...www dimplex com au 451903 66 18 FD 9501 A IX Appendix HPWH 300 HPWH 300HE...

Page 21: ...Glen Dimplex Australia Pty Ltd 1 21 Lionel Road Mount Waverley VIC 3149 www dimplex com au ph 1300 556 816 fax 1800 058 900 Subject to alterations and errors...