11 Device information

1

Type and order code

HPWH 300

HPWH 300HE

2

Design

2.1

Defrosting

yes

yes

2.2

Nominal cylinder volume litre

300

290

2.3

Transfer area of the internal heat exchanger m

2

-

1.45

2.4

Sensor pipe 

ø

 

 internal

 for external sensors

mm

-

12

2.5

Installation location

Outside

Outside

2.6

Cylinder material

Enamelled steel complying with 

DIN 4753

Enamelled steel complying with 

DIN 4753

2.7

Cylinder insulation

PU with sheet metal covering

PU with sheet metal covering

2.8

Nominal cylinder pressure

kPa (bar)

700 (7)

700 (7)

3

Operating limits

3.1

Heat source operating limit

1

°C

1. At temperatures below 0 °C ± 1 °C, the heating element is automatically switched on and the heat pump module off.

0 to 45

0 to 45

3.2

Domestic hot water in heat pump operation

°C

60 

± 1.0 K

60 

± 1.0 K

4

Sound

4.1

Sound power level 

dB(A)

65

65

5

Dimension/weight and filling quantities

5.1

Dimensions height (max.) x cross-section (max.)

mm

1680 x 700

1680 x 700

5.2

Weight (empty)

kg

145

160

5.3

Refrigerant R 134a/ filling weight

kg

1.0

1.0

6

Electrical connection

6.1

Degree of protection

IP 24

IP 24

6.2

Connection voltage

1/N/PE~230 V, 50 Hz

1/N/PE~230 V, 50 Hz

6.3

Fuse max.

A

C16

C16

6.4

Heat pump power consumption cos

A

0.8

0.8

6.5

Supplementary electrical heating power consumption

A

6.5

6.5

6.6

Power consumption max.

A

11.1

11.1

6.7

Heat pump nominal power consumption at 60°C

2

W

2. Heating up of the nominal volume from 15 °C to 60 °C at an air intake temperature of 20 °C and a relative humidity of 70 %

630

630

6.8

Supplementary electrical heating power consumption

W

1500

1500

6.9

Total power consumption max. 

W

2300

2300

7

Hydraulic connection

7.1

Circulation pipe connection external thread

R 3/4“

R 3/4"

7.2

Domestic hot water outlet connection external thread

R1“

R1"

7.3

Cold water inlet connection external thread

R1“

R1"

7.4

Internal heat exchanger connection external thread

-

R1"

8

Performance values

8.1

Heat-up time from 15 °C to 60 °C 

2

h

9.1

9.1

8.2

Mean heat output at 45 °C 

3

3. Heating up of the nominal volume from 15 °C to 45 °C at an air intake temperature of 20 °C and a relative humidity of 70 %

1870

1870

8.3

COP according to EN 16147 cycle XL

2.32

2.32

8.4

Useful domestic hot water quantity

Litres

419

419

8.5

Stand-by energy consumption at 55 °C  / 24 h

W

1.2

1.2

A H5 850 kPa PTR Valve must be fitted

A PSL 50 Valve (500 kPa) must be fitted

Summary of Contents for HPWH 300

Page 1: ...HPWH 300 HPWH 300HE Hot Water Heat Pump for Outdoor Installation English Installation and Operating Instructions FD 9501...

Page 2: ...N 4 4 Installation EN 5 4 1 Installation location EN 5 4 2 Installation EN 5 5 Assembly EN 5 5 1 Connecting the water pipes EN 5 5 2 Connecting the condensate hose EN 6 5 3 Electrical connection EN 6...

Page 3: ...ealand a TEMPER ING VALVE must be fitted by the installer The following are not permitted It is not permissible to operate the device The refrigerating system meets the requirements of ISO 5149 3 2014...

Page 4: ...mestic hot water temperature is higher than the temperature achievable by the heat pump approx 60 C it can be raised to a max of 85 C by means of the heating element NOTE When the domestic hot water t...

Page 5: ...ts the evaporator from freezing 3 Storage and transport 3 1 General The domestic hot water heat pump should always be stored and transported packaged in an upright position without being filled with w...

Page 6: ...e must be provided as shut off facility to avoid unnecessary energy losses Circulation is enabled according to use time or requirement control The nominal pipe widths for the on site sanitary installa...

Page 7: ...If the supply cord is damaged it must be replaced by a special cord or assembly available for the manufacturer or its service agent 6 Commissioning 6 1 Domestic hot water system ATTENTION The domesti...

Page 8: ...r heat pump possible fan coasting must be considered General The domestic hot water heat pump is virtually maintenance free Furthermore a one off visual inspection for possible leaks in the water syst...

Page 9: ...4753 part 6 8 Faults troubleshooting for the user ATTENTION Work on the domestic hot water heat pump is to be performed by qualified personnel only Observe accident prevention regulations The heat pum...

Page 10: ...nection 6 1 Degree of protection IP 24 IP 24 6 2 Connection voltage 1 N PE 230 V 50 Hz 1 N PE 230 V 50 Hz 6 3 Fuse max A C16 C16 6 4 Heat pump power consumption cos A 0 8 0 8 6 5 Supplementary electri...

Page 11: ...EN 10 451903 66 18 FD 9501 www dimplex com au English HPWH 300 HPWH 300HE...

Page 12: ...drawing A II 2 Integration Diagram A III 2 1 Process circuit diagram A III 2 2 Legend A III 2 3 Hydraulic integration diagram A IV 2 4 Legend A IV 2 5 Heat Exchanger Integration Diagram for Thermal S...

Page 13: ...JHU RXWSXW 5 H WHUQDO WKUHDG HDW H FKDQJHU LQSXW 5 H WHUQDO WKUHDG LUFXODWLRQ SLSH 5 H WHUQDO WKUHDG RW ZDWHU RXWOHW FRQQHFWLRQ 5 H WHUQDO WKUHDG RQGHQVDWH KRVH LQQHQ 6HDO YDOYH OHFWULFDO KHDWLQJ HOHP...

Page 14: ...3 14 15 Compressor Evaporator Hot water cylinder with Liquifier High pressure switch Check valve Air inlet temperature sensor R1 Filter dryer Expansion valve Cylinder temperature sensor Heating elemen...

Page 15: ...ng line drain line of the valve must not be blocked 8 Circulation pump 9 Outlet No connections for second heat generator required i e no heating water flow and no heating water return flow for hot wat...

Page 16: ...egration Diagram for Thermal Solar Installation HDW H FKDQJHU HDW H FKDQJHU ORZ 5HWXUQ IORZ KHFN YDOYH 7DS 7KHUPRPHWHU URP WKH FROOHFWRU 6DIHW YDOYH QWO IWXQJ H DHUDWLRQ 3XUJH 3UHVVXUH JDXJH DWFKPHQW...

Page 17: ...A VI 451903 66 18 FD 9501 www dimplex com au Appendix HPWH 300 HPWH 300HE 3 Circuit Diagrams 3 1 Last Load...

Page 18: ...www dimplex com au 451903 66 18 FD 9501 A VII Appendix HPWH 300 HPWH 300HE 3 2 Control...

Page 19: ...essor F17 Safety temperature limiter E1 H1 Electric heater indicator lamp J1 Digital inputs outputs U 230 V J3 Analogue inputs screw terminals K1 Compressor load relay K2 Starting relay for M1 K4 Load...

Page 20: ...www dimplex com au 451903 66 18 FD 9501 A IX Appendix HPWH 300 HPWH 300HE...

Page 21: ...Glen Dimplex Australia Pty Ltd 1 21 Lionel Road Mount Waverley VIC 3149 www dimplex com au ph 1300 556 816 fax 1800 058 900 Subject to alterations and errors...

Reviews: