www.dimplex.de/en
1810/C
EN-8
H 260E, H 260E eco
English
10.4 Reset to factory settings
Resets all settings made by the user to the pre-set fac
-
tory settings.
Hold down
and
until the Fr n display ap
-
pears.
Press
or
to select the Y display. The symbol
flashes.
Press the ENTER key. All values are reset to the
factory settings. Time display appears.
Set the time and date.
10.5 Temperature unit
Display can be set to degrees Celsius and degrees
Fahrenheit.
Hold down the MENU key until ° C display flashes.
Press
or
to select ° C or ° F.
Confirm with the ENTER key.
NOTE
NOTE
The temperature unit ° C is customary in most
European countries.
11. Warranty
This product is supplied with a two-year warranty
according to our terms of guarantee.
12. Note on disposal
Do not dispose of the unit with general
household waste. The device must be taken to
a local waste disposal plant.
13. Technical data
Glen Dimplex Deutschland GmbH
Tel.: +49 9221 709 545
Am Goldenen Feld 18
Fax.: +49 9221 709 924545
D - 95326 Kulmbach
E-mail: [email protected]
Model reference
H 260E
H 260E eco
Nominal voltage
1/N/PE, 230 V~, 50 Hz
Degree of protection
IP24
Dimensions (W x H x D)
300 x 405 x 120 mm
Weight
3.2 kg
Heat output
Nominal heat out
-
put
P
nom
2.0 kW
1.0 kW
Minimum heat
output (indicative)
P
min
1.0 kW
1.0 kW
Maximum contin
-
uous heat output
P
max, C
2.0 kW
1.0 kW
Auxiliary electricity consumption
At nominal heat
output
el
max
0.0 W
0.0 W
At minimum heat
output
el
min
0.0 W
0.0 W
In standby mode
el
SB
0.5 W
0.5 W
Type of control
Electronic room temperature controller with week program,
adaptive control of the heating start and operating time limit