Electrical

 

WARNING – THIS APPLIANCE MUST BE EARTHED 
The electrical installation must be carried out by a competent 
electrician, and be in strict accordance with the current I.E.E. 
regulations for Electrical Equipment in Buildings.
The wires in this mains lead are coloured in accordance with the 
following code :
GREEN AND YELLOW :   

EARTH

BLUE 

:    NEUTRAL

BROWN 

   LIVE

BLACK 

   PILOT 

WIRE

- see also ‘Pilot Wire Connection’.
The heater is fitted with a length of flexible cable type H05VV-F 
size 4 x 1.0mm2  for connection to the fixed wiring of the premises 
through a suitable connection box positioned adjacent to the 
heater.
A means for disconnection must be incorporated in the fixed 
wiring of the premises in accordance with the wiring rules. The 
supply circuit to the heater must incorporate a double pole 
isolating switch having a contact separation of at least 3mm.
Pilot Wire Connection
The BLACK control wire is designed to carry a signal from slot in 
or wall mounted Dimplex programmers. If, however a programmer 
is not being used, the pilot wire should be isolated in accordance 
with the current IEE Wiring Regulations.
IMPORTANT - DO NOT connect the BLACK pilot wire to earth. 
Care should be taken with the installation of the pilot wire(s) as 
when switching to background (set back) they become energised 
at 240V although only at a current of less than 100mA. In every 
case a suitable means of isolation must be provided for the pilot 
wire and marked to indicate that two sources of supply may be 
present at the heater.
Where pilot wires are installed separately from the heater final 
sub-circuit they should be protected, double insulated and carry 
their own integral earth continuity conductor.
Supplementary Earth Bonding
Should Equipotential Earth Bonding be required the earthing 
conductor in the supply cord is deemed to provide the 
supplementary bonding connection (see Regulation 547-03-05, 
17th Edition I.E.E. Wiring Regulations). 

Please note that lit cigarettes, candles and oil burners, 
combined with the convection effect of electric heaters 
can cause soot deposits to build up on the surface directly 
above and to the sides of the heater. This is not a fault of 
the heater. Extensive burning of candles or smoking in the 
operating environment of this product can produce heavy 
discoloration within a few months of use. 

Summary of Contents for Girona GFP 200 B

Page 1: ...ctions These instructions should be read carefully and retained for future use Note also the information presented on the appliance Girona Glass Panel Heaters Models GFP050 W B GFP075 W B GFP100 W B GFP150 W B GFP200 W B INDGUKP7RG ISSUE 3 ...

Page 2: ...his appliance can be used by children aged from 8 years and above and by persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintainance shall not be made by ch...

Page 3: ...in accordance with the current IEE Wiring Regulations IMPORTANT DO NOT connect the BLACK pilot wire to earth Care should be taken with the installation of the pilot wire s as when switching to background set back they become energised at 240V although only at a current of less than 100mA In every case a suitable means of isolation must be provided for the pilot wire and marked to indicate that two...

Page 4: ...Wall Mounting IMPORTANT The wall bracket supplied with the appliance must be used The heater should be positioned observing the minimum clearances stated around the heater see Fig 1 and Fig 2 DO NOT locate the heater immediately below a fixed socket outlet or connection box 1 Remove the wall mounting bracket from the back of the heater by depressing the spring latch at the top of each bracket see ...

Page 5: ...osition When the room temperature has reached the desired level the power to the elements will be reduced the heater will then maintain the room temperature at the chosen level NOTE Your heater may not come on when the thermostat slider is at a low setting This is due to the room temperature already being higher than the thermostat setting Background Temperature When used in conjunction with a rem...

Page 6: ...ssory module Before fitting a control module switch the heater off at the mains supply To insert a module the plug in protective cover on the right hand side of the thermostat unit at the back of the heater must first be removed Insert a flat head screwdriver into the side of the cover and prise away from the heater see Fig 7 Lift the cover away from the heater to reveal the slide in compartment I...

Page 7: ...tains at dusk to stop heat escaping through the windows 5 Windows Nearly 25 of heat loss can occur through poorly insulated frames and single glazing If you can t afford to double glaze all your windows go for the rooms you heat most 6 Treat your hot water tank give it a jacket An insulating jacket for hot water tanks costs only a few pounds and pays for itself within months Fit one that s at leas...

Page 8: ...nce as this may delay us providing you with a satisfactory service ACCIDENTAL DAMAGE IS NOT COVERED UNDER THE WARRANTY Your product is guaranteed for two years from the date of purchase Within this period we undertake to repair or exchange this product free of charge provided it has been installed and operated in accordance with these instructions Should you require assistance with this product pl...

Reviews: