• Avoid getting the unit wet. Do not let any liquid enter the unit.

• Do not place a container with liquid on top of the unit. 

•  The condensed water is not for drinking; either for humans or animals.

• Do not use bug sprays or flammable cleansers on the unit. 

• Do not lay the cord under carpets/rugs so that you can regularly check its condition.

• Do not touch the plug of the unit with wet hands. 

• Never use the cord of the unit as a carrying strap.

•  Before moving the unit, first switch off, then unplug and empty the water tank. It takes 

around 

2 minutes 

for the unit to stop.This allows the heater to cool down.

•  Always unplug the unit from the mains power source and wait for 

at least one hour

 

before carrying out any maintenance, transport or cleaning of the unit.

• Always switch the unit off and pull the plug out of the socket:

– If you are not using the unit.

– Before you clean the unit.

– Before you assemble the accessories.

– If a fault occurs.

– In the event of a storm.

•  Avoid over-twisting, coiling or pulling the power cord. Never use nylon or iron wire to tie 

the power cord.

• Do not use extension cords.

•  If the power cord is damaged, it must be replaced by an electrician or similarly qualified 

person, to avoid a hazard.

•  The power supply must conform to the specification shown on the rating plate at the 

back of the unit. 

•  The appliance shall be installed in accordance with national wiring regulations.

•  Never reach to retrieve the unit if it has fallen in water. In such case, immediately pull 

the plug. Have the unit checked before using it again.

•  This  appliance can be used by children aged from 8 years and above and persons 

with reduced physical, sensory or mental capabilities or lack of experience and 
knowledge if they have been given supervision or instruction concerning use of the 
appliance in a safe way and understand the hazards involved. Children should not play 
with the appliance. Cleaning and user maintenance should not be done by children 
without supervision.

• Appliances intended for indoor use (excluding laundry room).

•  While using DRY CLOTHES mode, please keep the unit AT LEAST 40CM away from 

the objects (ex. the clothes) and ensure no water drips into the air vent of the unit.

Summary of Contents for GDDEKD9

Page 1: ...1 9 LITRE DESICCANT DEHUMIDIFIER INSTRUCTION MANUAL GDDEKD9 Read and retain these instructions for future reference...

Page 2: ...Electric heating element max 650W Air volume max 200 m3 h Fan Ventilation Speed 3 Water tank volume 5L Working temperature range 1 32 C Timer 1 24 hours Continuous Drainage Yes Safety Device Tip over...

Page 3: ...ce and any flammable materials Ensure that there is at least 900mm from the top of the appliance and any flammable materials The unit contains a chemical substance The unit will emit a chemical smell...

Page 4: ...ling the power cord Never use nylon or iron wire to tie the power cord Do not use extension cords If the power cord is damaged it must be replaced by an electrician or similarly qualified person to av...

Page 5: ...ed to be a case of misuse The user operator not the manufacturer will be liable for any damage or injuries of any kind caused as a result of this DO NOT USE YOUR DESICCANT UNDER THE FOLLOWING ANY DAMA...

Page 6: ...6 PARTS 7 Parts Air Deflector Rear Plate Power Cord Control Panel Filter Frame Active Carbon Filter Humidity Indicator Front Plate Air Inlet Air Filter Water Tank...

Page 7: ...will run with fan ventilation only no heat Note In sleep mode the humidity indicator in the front plate will not light up PROGRAMMING FEATURE 8 Programming Feature 1 FAN SPEED Indicator Sleep NORM TU...

Page 8: ...allow clothes to dry faster The dehumidifier will work continuously at a target humidity level of 40 humidity high fan high heat The DRY CLOTHES indicator will light up The dehumidify will also rest...

Page 9: ...ATER FULL INDICATOR The light turns red and blinks when the water tank is full or if the tank is not in the correct position HUMIDITY INDICATOR IN THE FRONT This unit has a special HUMIDITY INDICATOR...

Page 10: ...O mode or DRY CLOTHES mode please refer to the description in the previous page IMPORTANT 1 After switching off the unit it takes at least 2 minutes for the unit to shut off completely this allows the...

Page 11: ...tank squarely from the unit 3 Remove the cover of the tank and carry it by its handle to empty the water 4 After the tank is emptied replace the tank cover and reinsert the water tank to the dehumidif...

Page 12: ...er of the continuous drain at the back of the unit 2 Unplug the water plug 3 Connect the drain hole with a water tube of inner diameter 11mm Please note the water tube is not supplied with the unit 4...

Page 13: ...ompletely empty the water tank and wipe it clean Cover the unit and store it where it will not be in direct sunlight CLEANING THE FILTER Draw out the air filter from the rear of the unit For dust filt...

Page 14: ...1 Too many doors and windows open 2 Other appliances increasing the rooms humidity Abnormal noises from the motor 1 Check and clean the air filter 2 The unit is not standing upright or is not level T...

Page 15: ...e 09 274 8265 Fax 09 274 8472 Email sales glendimplex co nz Web www dimplex co nz Glen Dimplex New Zealand Ltd 38 Harris Road East Tamaki Auckland New Zealand P O Box 58473 Botany Manukau 2163 New Zea...