Dimplex GDDEKD9 Instruction Manual Download Page 13

– 13 –

CLEANING THE FILTER

Draw out the air filter from the rear of the unit.

For dust filter and filter frame: 

1.  Use a vacuum cleaner or tap the filter lightly for easy cleaning. If the filter is particularly 

dirty, use warm water.

2. Make sure the filter is completely dry before replacing.

3. Do not expose the filter to sunlight. 

For HEPA filter: 

This filter is not washable. Its life span is variable and depends on the ambient conditions 
where the appliance is used. The filter should be checked periodically (about every 6 
months) and replaced if necessary. See the retailer where you purchased this product for 
spare filters.

STORAGE:

If the unit is not used for an extended period of time. Please:

• Turn the unit off, unplug and tidy the power cord.

• Completely empty the water tank and wipe it clean.

• Cover the unit and store it where it will not be in direct sunlight.

 

 

16 

 

CLEANING THE FILTER 
Draw out the air filter from the rear of the unit. 
 
 
 
 
 
 
 
 
 
 
 
 
 
For dust filter (washable filter) –   
1.

 

Use a vacuum cleaner or tap the filter lightly 

for easy cleaning. If the filter is particularly 

dirty, use warm water. 

2.

 

Make  sure  the  filter  is  completely  dry 
before replacing. 

3.

 

Do not expose the filter to sunlight. 

 

For active carbon filter –   
This filter is not washable. Its life span is variable and depends on the ambient conditions 

where the appliance is used. The filter should be checked periodically (about every 6 

months) and replaced if necessary.     

 

STORAGE 
If the unit is not used for an extended period of time. Please: 

l

 

Turing the unit off, unplug and tidy the AC cord. 

l

 

Completely empty the water tank and wipe it clean. 

l

 

Cover the unit and store it where it will not be in direct sunlight. 

                                                                   
 

HEPA Filter

Filter Frame

Summary of Contents for GDDEKD9

Page 1: ...1 9 LITRE DESICCANT DEHUMIDIFIER INSTRUCTION MANUAL GDDEKD9 Read and retain these instructions for future reference...

Page 2: ...Electric heating element max 650W Air volume max 200 m3 h Fan Ventilation Speed 3 Water tank volume 5L Working temperature range 1 32 C Timer 1 24 hours Continuous Drainage Yes Safety Device Tip over...

Page 3: ...ce and any flammable materials Ensure that there is at least 900mm from the top of the appliance and any flammable materials The unit contains a chemical substance The unit will emit a chemical smell...

Page 4: ...ling the power cord Never use nylon or iron wire to tie the power cord Do not use extension cords If the power cord is damaged it must be replaced by an electrician or similarly qualified person to av...

Page 5: ...ed to be a case of misuse The user operator not the manufacturer will be liable for any damage or injuries of any kind caused as a result of this DO NOT USE YOUR DESICCANT UNDER THE FOLLOWING ANY DAMA...

Page 6: ...6 PARTS 7 Parts Air Deflector Rear Plate Power Cord Control Panel Filter Frame Active Carbon Filter Humidity Indicator Front Plate Air Inlet Air Filter Water Tank...

Page 7: ...will run with fan ventilation only no heat Note In sleep mode the humidity indicator in the front plate will not light up PROGRAMMING FEATURE 8 Programming Feature 1 FAN SPEED Indicator Sleep NORM TU...

Page 8: ...allow clothes to dry faster The dehumidifier will work continuously at a target humidity level of 40 humidity high fan high heat The DRY CLOTHES indicator will light up The dehumidify will also rest...

Page 9: ...ATER FULL INDICATOR The light turns red and blinks when the water tank is full or if the tank is not in the correct position HUMIDITY INDICATOR IN THE FRONT This unit has a special HUMIDITY INDICATOR...

Page 10: ...O mode or DRY CLOTHES mode please refer to the description in the previous page IMPORTANT 1 After switching off the unit it takes at least 2 minutes for the unit to shut off completely this allows the...

Page 11: ...tank squarely from the unit 3 Remove the cover of the tank and carry it by its handle to empty the water 4 After the tank is emptied replace the tank cover and reinsert the water tank to the dehumidif...

Page 12: ...er of the continuous drain at the back of the unit 2 Unplug the water plug 3 Connect the drain hole with a water tube of inner diameter 11mm Please note the water tube is not supplied with the unit 4...

Page 13: ...ompletely empty the water tank and wipe it clean Cover the unit and store it where it will not be in direct sunlight CLEANING THE FILTER Draw out the air filter from the rear of the unit For dust filt...

Page 14: ...1 Too many doors and windows open 2 Other appliances increasing the rooms humidity Abnormal noises from the motor 1 Check and clean the air filter 2 The unit is not standing upright or is not level T...

Page 15: ...e 09 274 8265 Fax 09 274 8472 Email sales glendimplex co nz Web www dimplex co nz Glen Dimplex New Zealand Ltd 38 Harris Road East Tamaki Auckland New Zealand P O Box 58473 Botany Manukau 2163 New Zea...