Dimplex GDC12RBA Instructions For Use Manual Download Page 9

 

Model No. 

GDC14RCWA / GDC14RCBA 

Power Source 

220-240V~ 50Hz AC 

Power Consumption 

(EN14511) 

1660W/1660W 

Rated Power 

(EN60335) 

 

1700W 

Cooling Capacity 

4000W 

Heating Capacity 

4000W 

Air Flow 

450 M

3

/H 

Moisture Removed 

60 L/DAY 

Refrigerant R410A 

Min. room size 

10m

2

 

Dimensions (mm) 

476W x 358D x 840H 

Net Weight 

32.5KG 

 

If you have any issues with your unit, please contact Glen Dimplex for 

your nearest service agent. Proof of purchase is required at the time of 

service. 

 

 

 

Glen Dimplex Australasia Ltd 

Glen Dimplex Australia Pty Ltd 

38 Harris Road, East Tamaki, 

2/205 Abbotts Road, 

Manukau, Auckland 2013

 

Dandenong South VIC 3175 

 

New Zealand 

Australia 

Ph: (09) 274 8265

 

Ph: 1300 556 816

 

Fx: 0800 112 020

 

Fx: 1800 058 900

 

 

Summary of Contents for GDC12RBA

Page 1: ...ned off please wait at least 3 minutes before restarting it This is to prevent the compressor from being damaged 7 This unit needs to be plugged into a 10 Amp power point Please do not use any extensi...

Page 2: ...eated air system design heats instantly whenever you want it Powerful dehumidification process and filtered air cycle for improved breathing conditions If the remote control function is not required y...

Page 3: ...it is pressed to a maximum of 30 4 TEMPERATURE REGULATION KEY DOWN This key lowers the preset temperature by 1 each time it is pressed to a minimum of 17 In normal conditions the temperature data whi...

Page 4: ...Indicates the water is full inside Please contact an authorized service centre if any of the above error messages are shown cally after the set time is over 8 SLEEP CONTROL When setting the sleep com...

Page 5: ...r Reverse cycle Cooling Heating models only GDC12RCWA GDC12RCBA GDC14RCWA GDC14RCBA This unit can evaporate the condensation and flow out through the exhaust hose automatically when the unit is in the...

Page 6: ...se follow the arrow direction and push the filter lightly Then take out the filter for cleaning POWER SUPPLY 1 Confirm the correct power 2 Insert the plug into the power outlet firmly In case of a dan...

Page 7: ...the unit is not placed against objects which will obstruct air intake e g furniture or curtains as this will affect it s performance drastically Do not place the unit in direct sunlight as this may c...

Page 8: ...he control panel Make sure the remote control is correctly aimed at the control panel The remote control does not function The batteries are drained Replace the batteries To correct problems not menti...

Page 9: ...10m 2 Dimensions mm 476W x 358D x 840H Net Weight 32 5KG If you have any issues with your unit please contact Glen Dimplex for your nearest service agent Proof of purchase is required at the time of s...

Reviews: