5. L.E.D. DISPLAY

     Indicates the current room temperature or the time setting. If it’s   

adjusted by the user the display will return to the pre-set temperature 

automatically. 

 

 

 

 

6. SPEED                       

Press to select LOW, MEDIUM, HIGH or AUTO fan speed. 

                         If "AUTO" is selected, the unit operates at maximum cooling 

                         capacity when the room temperature less the setting temperature 

                                                  is above 2

                                                  When the room temperature less the set temperature is below 

                                                  2

, the unit operates at middle cooling capacity. 

                         When the room temperature equal the set temperature, the 

                         unit operates at minimum capacity. 

                          If "HIGH" is selected, the unit operates at maximum cooling 

capacity regardless of the pre-set temperature. Similar operation is 

applied when "MEDIUM" OR “LOW" is manually selected. 

 

 

7. PROGRAMMABLE

    Programmable timer ON/OFF key. 

    TIMER

               TIMER-ON: The timer-on key is used to turn the unit on 

    automatically when the set time is reached. 

(The indicator light will be turned on when the timer is 

functioning.) 

1. Press the "TIMER" key at stand-by status to set the time. 

Choose the function desired (refrigeration, heat or 

dehumidification.) 

2. Once the set hour has come to an end, the unit will turn on 

automatically. 

3. If you press the “POWER” key before the timer is complete, the 

set time will be cancelled and the unit will remain turned on. 

TIMER-OFF: The timer-off is used to turn the unit off automati- 

Error Display 

E1: Indicates open circuit or short circuit in room temperature sensor. 

E2: Indicates open circuit or short circuit in pipe temperature sensor. 

E7: Indicates the water is full inside. 

Please contact an authorized service centre if any of the above error messages are shown

cally after the set time is over. 

 

8. SLEEP CONTROL

     

When setting the "sleep comfort" mode please ensure that you 

 

 

FUNCTION

                       

then set the number of hours required and press the timer 

 

button till those hours are indicated on the L.E.D display. After 

setting the hours the L.E.D. display will automatically return to 

the current pre-set temperature. To increase this setting press 

the "UP" button and for each press, the temperature will be 

increased by 1

. Likewise to set for a lower temperature, press 

the “DOWN” button and for each press, the temperature will be 

decreased by 1

During the course of this cycle, to ensure maximum sleep 

comfort, the micro-processor memory will raise the pre-set 

temperature 0.5

  each half hour to a maximum of 2

 over two 

hours and then maintain that temperature for the balance of the 

time set. 

The portable air conditioner is fitted with a 3 minute compressor 

delay protection circuit which simply means that the compressor 

requires 3 minutes to start. From either being switched on, or 

when changing from “dehumidify” to any air conditioning cycle 

chosen. 

 

9.”E7”

                   When the unit warns of full water, please unplug the water 

stopper at the back of the unit and then lean the unit to drain the 

water out. Then the unit can be restarted. If the error: E7 is 

presented again, please find a specialized person to repair.

 

 

Note: Heating function does not operate if the ambient temperature is over 23

℃. 

Cooling function does not operate if the ambient temperature is over 

43

℃. 

(Heating function is only available in the following models: 

GDC12RCWA / GDC12RCBA / 

GDC14RCWA / GDC14RCBA)

 

Summary of Contents for GDC12RBA

Page 1: ...ned off please wait at least 3 minutes before restarting it This is to prevent the compressor from being damaged 7 This unit needs to be plugged into a 10 Amp power point Please do not use any extensi...

Page 2: ...eated air system design heats instantly whenever you want it Powerful dehumidification process and filtered air cycle for improved breathing conditions If the remote control function is not required y...

Page 3: ...it is pressed to a maximum of 30 4 TEMPERATURE REGULATION KEY DOWN This key lowers the preset temperature by 1 each time it is pressed to a minimum of 17 In normal conditions the temperature data whi...

Page 4: ...Indicates the water is full inside Please contact an authorized service centre if any of the above error messages are shown cally after the set time is over 8 SLEEP CONTROL When setting the sleep com...

Page 5: ...r Reverse cycle Cooling Heating models only GDC12RCWA GDC12RCBA GDC14RCWA GDC14RCBA This unit can evaporate the condensation and flow out through the exhaust hose automatically when the unit is in the...

Page 6: ...se follow the arrow direction and push the filter lightly Then take out the filter for cleaning POWER SUPPLY 1 Confirm the correct power 2 Insert the plug into the power outlet firmly In case of a dan...

Page 7: ...the unit is not placed against objects which will obstruct air intake e g furniture or curtains as this will affect it s performance drastically Do not place the unit in direct sunlight as this may c...

Page 8: ...he control panel Make sure the remote control is correctly aimed at the control panel The remote control does not function The batteries are drained Replace the batteries To correct problems not menti...

Page 9: ...10m 2 Dimensions mm 476W x 358D x 840H Net Weight 32 5KG If you have any issues with your unit please contact Glen Dimplex for your nearest service agent Proof of purchase is required at the time of s...