NOTE: THE SWITCH HAS BEEN FACTORY SET FOR 1kW OPERATION. IF
ADDITIONAL OUTPUT IS REQUIRED, 2kW CAN BE SET ON INSTALLATION.
SUPPLY CABLE IS NOT SUPPLIED WITH THIS APPLIANCE AND IT
SHOULD THEREFORE BE INSTALLED BY A COMPETENT ELECTRICIAN
IN ACCORDANCE WITH THE LATEST IEE REGULATIONS.
Safety
Cut-Out
For your safety, this appliance is fitted with a thermal cut-out. In the
event that the product overheats, the cut-out switches the heater off
automatically.
To bring the heater back into operation, remove the cause of overheating,
then turn off the electrical supply to the heater for a few minutes.
When the heater has cooled sufficiently reconnect and switch on the
heater.
Fuse Link
A thermal fuse link is provided as an added safety feature. If the fuse link
operates and opens circuit it is the result of abnormal overheating within
the appliance.
To ensure the future safe operation of the heater please contact Dimplex
Customer Services using the details at the end of the user instructions.
Installation
WARNING: Minimum clearances must be adhered to when
mounting the heater.
Before undertaking installation work, ensure the electricity supply is
disconnected from any relevant fixed wiring. Supply cable is not supplied
with this appliance and it should therefore be installed by a competent
electrician in accordance with the latest IEE wiring regulations.
The supply circuit must be adequate for the input of the appliance and
must be protected with a 13A fuse.
A suitable termination to the fixed wiring of the premises must be provided
adjacent to the final position of the appliance through a double pole
switch having a contact separation of at least 3mm in all poles.
Installation Procedure
It is essential to observe minimum wall mounting clearances - see
Fig. 1
.
The appliance should be fitted horizontally, with the cable entry at the top
and grille at the bottom. It must be mounted not less than 1800mm above
the floor with a clearance of at least 600mm to any shelf or projecting
surface below the heater and not less than 300mm below the ceiling or
other projecting surface. It must also be not less than 250mm from an
adjacent projecting surface. For most effective heating performance,
the heater should be mounted at the minimum height : i.e. 1800mm above
the floor.
Care must be taken to ensure that when in use, the air stream is not
obstructed by a high shelf or cabinet.
The appliance is secured to the wall with three screws, two through
keyhole slots ‘1’ and ‘3’ and one through a hole ‘2’ to hold the appliance
firmly in position (see
Fig. 2
).
Downflow Fan Heater
Model : FX 20E IPX4
Installation and Operating Instructions
Dimensions
(millimetres)
Model Specification
FX 20E IPX4 (High level) 1or 2kW + electronic, run-back timer
Fig. 1
(IP24)
IMPORTANT SAFETY ADVICE
WARNING - DO NOT USE THIS HEATER IN THE IMMEDIATE
SURROUNDINGS OF A BATH, A SHOWER OR A SWIMMING POOL.
DO NOT COVER THE APPLIANCE or place material or
garments on it, or obstruct the air circulation around this
appliance, for example with curtains or furniture, as this
could cause overheating and a fire risk.
DO NOT PLACE AEROSOLS OR OTHER CONTAINERS
SUSCEPTIBLE TO HEAT IN THE DIRECT AIRFLOW FROM THE
UNIT.
THIS HEATER MUST NOT BE LOCATED IMMEDIATELY BELOW
A FIXED SOCKET OUTLET.
This heater must be installed so that the switches and
other controls cannot be touched by the person in the bath
or shower.
WARNING- Do not operate the heater with the top cover
removed. This will trip the fuselink.
The appliance is not intended for use by children or other
persons without assistance or supervision if their physical,
sensory or mental capabilities prevent them from using it
safely. Children should be supervised to ensure that they
do not play with the appliance.
WARNING – DISCONNECT THE HEATER FROM THE ELECTRICITY
SUPPLY BEFORE UNDERTAKING SERVICE OR REPAIR.
WARNING – If the appliance is fitted in a bathroom, a cable
outlet will be necessary with the supply to the unit
controlled by a double pole switch. The switch if inside
the bathroom should be pull cord operated and if outside
should be adjacent to the entrance door. The appliance
must be mounted so that no part of it can be touched by
any person using bath or shower.
THIS HEATER MUST NOT BE OPERATED WITHOUT THE COVER
CORRECTLY IN POSITION.
Warning - In order to avoid a hazard due to inadvertent
resetting of the thermal cutout, this appliance must not be
supplied through an external switching device, such as a
timer, or connected to a circuit that is regularly switched
on and off by the utility.
General
The heater has a loading of 2kW. It is designed for permanent wall
mounting and is suitable for operation on A.C. electricity supply having
the same voltage as shown on the rating label.
The heater is fitted with an internally mounted selector switch which on
installation of the heater allows a choice of 1kW or 2kW output to suit the
dimensions of the room to be heated.
In rooms of less than 9 – 11 cubic m. (350 - 400 cubic ft.) 1kW output
should be selected, otherwise nuisance tripping of the thermal overload
cut-out may occur.
08/35386/3 Issue 3
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE