WARNING:
This heater must be properly installed before
it is used.
CONTROLS
• Fan Delay -
The heater is equipped with a fan delay
control. There will be a short delay to enable the heating
elements to warm up before the fan turns on. The fan
will also remain on for a few moments after the elements
are de-energized.
• Automatic High Limit
- Each heater is equipped with
automatic reset thermal cutouts. Should these safety
switches operate, they will automatically reset once the
element reaches a safe operation temperature, however,
the cause of the high limit condition should be deter-
mined and corrected to sure satisfactory operation.
OPTIONAL CONTROLS
• Integral thermostats
- All units are available with a
built-in snap-action thermostat. The sensing element
is located in the return air stream to provide accurate
temperature control. The thermostat has a range of 40
F (low) to 100 F (high). It can be manually operated or
rendered tamper-proof as desired. This control can be
field-mounted or factory mounted.
• Remote Line Voltage Thermostat
- All units can be
Maintenance
CAUTION:
Before removing the front cover for cleaning,
make certain the power has been turned off at the circuit
breaker panel.
CAUTION:
Allow adequate time for the element and body
casing to cool before attempting to work on the heater.
1. Under normal conditions, the heater should be cleaned
once a year.
DISCONNECT ALL POWER
before
cleaning or servicing the heater.
2. All motors are lubricated for extended life operation, and
will not have to be oiled.
Warranty
The Manufacturer warrants the heating elements and components
of the enclosed product against any defect in material or
workmanship for a period of one year from the date of purchase. In
full satisfaction of any claims under this Warranty the Manufacturer
will repair or replace without charge, in its factory or in the field as it
alone may decide, any parts which in its opinion are defective.
The Manufacturer shall not be responsible for any transportation
or shipping costs in relation to such repair or replacement except
as specifically assumed by it. Misuse of this product or repairs by
persons other than the Manufacturer’s authorized personnel without
the Manufacturer’s written approval, will void this Warranty.
This Warranty is in lieu of all other warranties or conditions
whether express or implied including but not limited to those of
merchantability or fitness for purpose and shall constitute the sole
remedy of the Purchaser and the sole liability of the Manufacturer in
respect of the sale of the product, whether in the nature of breach or
breach of fundamental term, or of negligence or otherwise.
The Manufacturer shall not be liable for any special, indirect or
consequential damages or for any damages resulting from removal
or replacement of a heater subject to warranty claim without the
Manufacturer’s authorization.
This Warranty is transferable by the original consumer purchaser
of the product. Any claims under this Warranty must be submitted
in writing to the Service Manager, Dimplex North America Ltd., 1367
Industrial Rd., Cambridge, Ontario N1R 7G8, Canada.
In keeping with our policy of continuous product improvement, we reserve the right to make changes without notice.
© 2013 Dimplex North America Limited
1367 Industrial Road Cambridge ON Canada N1R 7G8
1-888-346-7539 www.dimplex.com
connected to a line-voltage remote thermostat. A special
control terminal block is provided in all units to facilitate
easy connection of the remote thermostat control wiring.
• Remote Low Voltage Thermostat with Relay
- A low
voltage transformer/relay can be field or factory installed
with the unit for remote low voltage thermostatic control.
The special control terminal block is utilized for this op-
tional control feature.
• Fan-Only Switch -
An optional fan-only switch is avail-
able for integral mounting within the unit. This switch
provides continuous fan-operation, independent of the
built-in or optional remote thermostatic control, which is
effective in eliminating air stratification.
START UP
1. Before the unit is energized, the discharge louvres
should be adjusted for desired air deflection.
2. Check to see that all controls and optional accessories
are operation properly.
Figure 2
Operation