Deluxe Wall Mounted Fan Heater

EF12 Series

 Installation Instructions

 

IMportant InStructIonS

Read all instructions before using this appliance and retain 

for future reference.

The heater is splash proof and is suitable for operation 

1. 

on a 208/240 Volt electrical supply.

The fan heater has a maximum load of 1.5 kW at 208 

2. 

Volt and 2kW at 240 Volt, and is designed for permanent 

wall mounting on the bracket supplied only.

The device is only suitable for room heating within 

3. 

enclosed rooms.

Repairs and corrective measures may only be carried out 

4. 

by a qualified technician.

Disconnect the power supply in the event of a fault (pull 

5. 

out the device plug or switch off the fuse).

Observe the minimum clearances.

6. 

Children or persons who are not capable of operating 

7. 

the device safely must not operate the heater. Ensure 

that children do not play with the device or are left 

unsupervised in the vicinity of the heater.

Do not operate the heater in rooms where highly 

8. 

flammable substances are used (e.g. solvents, etc.).

Connecting lead must not be laid over the device.

9. 

Potential dangers can arise when the device switches on 

10. 

automatically, e.g. devices which have been covered or 

blocked by objects since they were last used can cause 

fire.

The outer surfaces of the device, and in particular the air 

11. 

outlet grid, become hot during operation.

Do not place aerosols or other containers susceptible to 

12. 

heat in the direct air flow of the unit.

Do not cover the heater.  To prevent overheating and 

13. 

possible fire, do not place material or garments on the 

heater, or obstruct the air inlet or outlet grille.

SavE tHESE InStructIonS

 WarnInG:

  Do not install the heater immediately below a 

fixed socket outlet.

 

WarnInG:

  If installing in a bathroom, heater must not 

be installed in such a location that a person using a bath or 

shower can reach the switches and other controls.
See Figure 1 for dimensions of the heater.
The heater must only be installed and operated on a 

vertical wall as shown in Figure 2. Clearance from any 

vertical surface must be no less than one (1) inch (25 mm), 

clearance from any horizontal surface must be no less than 

9¼ inches (230 mm) to the bottom of the heater and 12 

inches (300 mm) to the top.
In addition, a minimum clearance of three (3) feet (900 

mm) between inflammable objects e.g. curtains, towels or 

heat-sensitive plastics, and the front of the unit must be 

maintained. 

Electrical connection

Verify that the supply voltage is the same as that stated on 

the heater (AC supply only).
This heater is designed for use on a 208/240V 60Hz AC 

single-phase supply.  Connection requires a supply wire 

that must consist of two wires plus ground and have a rating 

capable of handling all loads on the circuit.  
Make all relevant electrical connections within an installed 

junction box and ensure all wiring meets all local electrical 

and building codes. Where local code requires the 

disconnection of all ungrounded supply lines, a double pole 

isolating switch must be fitted to facilitate isolation.

Connection to the heater should be made using the provided 

fitted cable clamp assembly at the back of the heater to meet 

local code requirements.

 

WarnInG:  

Always use a qualified and licensed 

electrician for all wiring and electrical connections.  Improper 

wiring could lead to a fire hazard.

250

300

280

405

250

11¾”

(300 mm)

16”

(405 mm)

4¾”

(120 mm)

Figure 1

250

300

280

405

250

Figure 2

>1”

(25 mm)

>9¼”

(230 mm)

>12”

(300 mm)