Technical Data
Table 7: Direct Electric Product features
# Not including insulation
Direct Electric Cylinder Range – Product Features
Materials
- inner cylinder
Duplex stainless steel LDX2101
- outer cylinder
HIPS
- inlet/outlet
Stainless steel
- insulation
60mm PU foam (GWP=1, ODP=0)
Maximum operating conditions
- potable water temperature
70
°
C
- operating pressure
3 bar
Cold water supply
- minimum dynamic pressure
1.5 bar
- maximum pressure
12 bar
- minimum flow rate
15 l/min
Connections
- cold water inlet
22mm stainless steel
- hot water outlet
22mm stainless steel
Immersion heater
1
¾
F BSP
3kW
Thermostatic control
- direct input
integral immersion heater thermostat and cut out
Safety components
- pressure reducing valve and strainer
3 bar
- expansion relief valve
6 bar
- temp. and pressure relief valve
7 bar/90
°
C
- factory pressure test
12 bar
Other features
Over 60% in volume from recycled materials#
Surface mounted sensor devices for compatibility and
ease of maintenance
Approvals
KIWA approval number:- 1112700
KIWA
KIWA
Guarantee
- inner cylinder
25 yrs
- immersion heaters
2 yrs - excluding the effects of lime scale or other water
borne contaminants
- other components
2 yrs - excluding expansion vessel membrane pressure