background image

Dimensions (millimetres)

Model Specification

DXC20TIE7: 2.0kW convector heater with electronic controls

DXC30TIE7: 3.0kW convector heater with electronic controls

DXC30FTiE7: 3.0kW convector heater with electronic controls and  

 

        turbo boost 

Electrical Connection

WARNING: THIS APPLIANCE MUST BE EARTHED

The use of an extension lead or multi-plug adaptor is not adviced when connecting this product to the mains. Connection through these 

deviced could lead to risk f overloading, overheating and even fire at the extention lead or adaptor due to inadequate connection quality

This heater must be used on an AC (~) supply only and the voltage marked on the heater must correspond to the supply voltage. This 

heater is fitted with a rewirable plug incorporating a a 13 amp fuse. In the event of replacing the fuse in the plug supplied, a 13 amp fuse 

approved by ASTA to BS 1362 must be used. If any other type of plug is used, a 15 amp fuse must be fitted in the plug, the adaptor, or at 

the distribution board.

IMPORTANT: If the plug is not suitable for your socket, the 13 amp plug should be removed. Before wiring the appropriate plug, please note 

that the wires in this mains lead are coloured in accordance with the following code: 

GREEN AND YELLOW: 

 

EARTH

BLUE: 

   NEUTRAL

BROWN: 

   LIVE

Connect the GREEN AND YELLOW wire to the terminal marked ‘E’ or by the earth symbol, or coloured GREEN or GREEN AND YELLOW. 

Connect the BROWN wire to the terminal marked ‘L’ or coloured RED. Connect the BLUE wire to the terminal marked ‘N’ or coloured 

BLACK

230
MIN

695 - 3.0kW
575 - 2.0kW

418

150

450 

MIN

350

250 

MIN

Technical Data

Model Identifier(s)

DXC20TIE7

DXC30TIE7

DXC30FTIE7

Heat output (kW)

Nominal heat output

Pnom

2

3

3

kW

Minimum heat output (indicative) 

Pmin

2

3

3

kW

Maximum continuous heat output

Pmax,C

2

3

3

kW

Auxillary electricity Consumption

At nominal heat ourput

elmax

0.00

0.00

0.00

kW

At minimum heat output

elmmin

0.00

0.00

0.00

kW

In standby mode

elSB

0.00

0.00

0.00

kW

Tubo Fan

N

N

Y

Contact details

Glen Dimplex Heating and Ventilation, Millbrook House, Grange Drive, 

Hedge End, Southampton, SO30 2DF

WARNING:  DO NOT USE THE HEATER UNTIL THE FEET OR WALL BRACKETS ARE FITTED CORRECTLY

The product can be used as an installed or portable unit. Once the desired application has been decided upon and the requirements below have 

been met the product is ready to be used. Simply plug in and switch on at the wall socket.

There are various control options available with various combinations via the membrane buttons and segmented display. Please note - the 

element has been coated with a protective film which will burn off during the first few minutes of use and may cause a small amount of fuming. 

This is quite normal - the fumes are non-toxic and will quickly disappear. We recommend that you open a window to ventilate the room when 

using the heater for the first time.

Using the Heater

Summary of Contents for DXC20TIE7

Page 1: ...Convector Heaters Model DXC20TIE7 DXC30TIE7 DXC30FTIE7 These instructions should be read carefully and retained for future use Note also the information presented on the appliance INSTRUCTION MANUAL...

Page 2: ...ision or instruction concerning the use of the appliance in a safe way and understand the hazard involved Children aged from 3 years and less than 8 years shall not plug in regulate and clean the appl...

Page 3: ...the earth symbol or coloured GREEN or GREEN AND YELLOW Connect the BROWN wire to the terminal marked L or coloured RED Connect the BLUE wire to the terminal marked N or coloured BLACK 230 MIN 695 3 0...

Page 4: ...the brackets as follows Lay the heater on its back Following the sequence in Fig 1 identify and remove the fixing screw securing the brackets located beside the mains cable as shown in a then pull out...

Page 5: ...s are specified at the factory These must be defined by the user as required NOTE In time block OFF frost protection is set at the factory If the room temperature is 5C or less the heating device is s...

Page 6: ...ime block OFF Press the ENTER key P1 program 1 and OFF appears The hours display flashes Use the keys to set the hours Press the ENTER key The minutes display flashes Use the keys to set the minutes T...

Page 7: ...must provide to Dimplex or its authorised agents on request the original receipt as proof of purchase and if required by Dimplex proof of delivery If you are unable to provide this documentation you w...

Page 8: ...hts reserved Material contained in this publication may not be reproduced in whole or in part without prior permission in writing of Glen Dimplex This product complies with the European Safety Standar...