ATTENTION!

In order to avoid a hazard due to inadvertent
resetting of the thermal cutout, this appliance
must not be supplied through an external
switching device, such as a timer or
connected to a circuit that is regularly
switched on and off by the utility.

ATTENTION!

Connection only to fixed installed cables! The
hardwired electrical installation must be
provided with a disconnect device with a
contact grap of at least 3 mm at each pole
(e.g. automatic circuit breaker)!

2

Technical data

Connection voltage: 1/N/PE~, 230 V, 50 Hz

Protection type: 

 IP20

Protection class:

I (with protective conductor)

3

Mounting, Installation, Minimum Clearances

The heating device may only be installed as shown, i.e.
on a horizontal, even surface. Using it on deep-pile car-
pets is not permitted. Please use caution when install-
ing it in front of flammable objects. Installation below a
wall socket is not permissible. Minimum clearances
must be observed.

In addition, a minimum clearance of 500 mm between
flammable objects e.g. curtains, towels or heat-sensi-
tive plastics and the front of the unit must be main-
tained.

The heating device must be aligned horizontally and in-
stalled on a vertical wall (see illustration). 
Make sure that the inflow and outflow of air at the top
and bottom of the device are unimpeded

.

It is not permissible to install the device in protection 
zones as defined in VDE 0100 part 701.

3.1 Wall mounting

ATTENTION!

The original wall mounting bracket supplied, located at
the back of the heater, must be used. 

Remove the bracket from the back of
the device by pressing the springs on
each side.

Drill the fixing holes for the wall mount-
ing bracket.

Firmly secure bracket to the wall using suitable
screws.

Insert heater in wall bracket making use of the slots
on the back of the heater. Snap heater in place at
the top of the wall bracket.

4

Electrical Connection

The voltage specified on the type plate must match the
local mains voltage.
The device plug must always be accessible.
The heaters are fitted with a power supply cable with-
out plug. The supply cord must be connected to a con-
nection box dedicated to the heater.

Type

Heat out-

put (W)

Width 

(mm)

Height   

(mm)

Depth  

(mm)

Weight 

(kg)

DX 410

1000

575

350

124

4,1

DX 415

1500

575

350

124

4,1

DX 420

2000

575

350

124

4,1

DX 425

2500

695

350

124

4,8

DX 430

3000

695

350

124

4,8

Type

Heat output (W)

A (mm)

DX 410

1000

354

DX 415

1500

354

DX 420

2000

354

DX 425

2500

476

DX 430

3000

476

Summary of Contents for DX 410

Page 1: ...tage et d utilisation esk Polski N vod k mont i a pou it Instrukcja monta u i obs ugi Hrvatski Monta ne i pogonske upute Wandkonvektor Wall Convector Heater Mural Convecteur 04 15 B Bestell Nr Order n...

Page 2: ...M ngel geschied dadurch dass die mangelhaften Teile unentgeldlich nach unserer Wahl instantgesetzt oder durch einwandfreie Teile ersetzt werden Durch Art oder Ort des Einsatzes des Ger tes bedingte au...

Page 3: ...re Vorsicht ist geboten wenn Kinder oder schutzbed rftige Personen anwesend sind ACHTUNG Das Ger t darf nicht unter einer Wandsteck dose aufgestellt werden ACHTUNG Wenn das Netzkabel besch digt ist mu...

Page 4: ...t Mindestabst nde beachten Ferner ist auch an der Ger tevorderseite ein Abstand von mindestens 500 mm zu leicht entz ndbaren Ge genst nden wie z B Vorh ngen Handt chern oder w rmeempfindlichen Kunstst...

Page 5: ...zur ckschalten kann Anschlie end m gliche Ursache beseitigen z B Luft gitter verstellt oder abgedeckt Wenn das Ger t ausrei chend abgek hlt ist kann es wieder in Betrieb genom men werden 7 St rungen...

Page 6: ...s Particular attention has to be given where children and vulnerable people are present ATTENTION If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly q...

Page 7: ...unit must be main tained The heating device must be aligned horizontally and in stalled on a vertical wall see illustration Make sure that the inflow and outflow of air at the top and bottom of the de...

Page 8: ...again Then remove the cause e g when the air grid is blocked or covered When the device has cooled suffi ciently it can be started up again 7 Faults If the heating device does not give off heat check...

Page 9: ...qualification comparable afin d liminer les sources de danger ATTENTION Il est interdit de poser l appareil sous une prise murale ATTENTION Pour viter la surchauffe l appareil ne doit pas tre couvert...

Page 10: ...haleur La fiche de l appareil doit tre accessible une fois l ap pareil mont L appareil de chauffage doit tre install l horizontal sur un mur vertical comme repr sent ci dessous Veiller ce que l air pu...

Page 11: ...s retirer la prise secteur et laisser l appareil d bran ch durant quelques minutes jusqu ce que le limiteur de temp rature puisse r trograder Puis liminer la cause possible grille d air recouverte ou...

Page 12: ...GR 12 DX410_430_gr 04 15 B www dimplex de DX410 DX415 DX420 DX425 DX430 1 8 3 3 8 3 8...

Page 13: ...50 Hz IP20 I 3 500 mm VDE 0100 701 3 1 W mm mm mm DX 410 1000 575 350 124 4 1 kg DX 415 1500 575 350 124 4 1 kg DX 420 2000 575 350 124 4 1 kg DX425 2500 695 350 124 4 8 kg DX 430 3000 695 350 124 4...

Page 14: ...415 DX420 DX425 DX430 4 5 C 5 C D E I 1000 W II 2000 W Glen Dimplex Deutschland GmbH Am Goldenen Feld 18 D 95326 Kulmbach 6 7 E FD 8 Robert Bosch Hausger te GmbH 2 9 10 2 11 49 9221 709 564 49 9221 70...

Page 15: ...zbjeglo pregrijavanje ure aj ne smije biti prekriven POZOR Ure aj se ne smije upotrebljavati u prostorijama s kadom tu em ili bazenom kao ni u blizini umivaonika ili priklju aka za vodu POZOR Ovaj sim...

Page 16: ...e vodove i cjevo vode u zidu Zidni nosa vrsto pri vrstite na zid prilo enim vij cima Objesite ure aj u donje proreze zidnog nosa a Stavite ure aj u uspravni polo aj i pritisnite ga dok se ne uglavi u...

Page 17: ...j slu bi Za obradu naloga bit e potrebni E i FD broj ure aja Ove specifikacije prona i ete na ozna noj plo ici Popravke i zahvate na ure aju smije obavljati samo kvalificirani elektri ar ili servisna...

Page 18: ...cno nagrzewa i powodowa poparzenia Szczeg ln ostro no nale y zachowa w obecno ci dzieci lub os b wymagaj cych opieki UWAGA Urz dzenia nie wolno ustawia pod gniazdkiem przy cianie UWAGA W przypadku usz...

Page 19: ...y przestrzega minimalnych od st p w Ponadto nale y zachowa co najmniej 500 mm od st pu od przodu urz dzenia do atwopalnych przed miot w np zas on r cznik w lub wra liwych na ciep o tworzyw sztucznych...

Page 20: ...e przez kilka minut tak aby ogra nicznik temperatury m g si ponownie za czy Nast pnie nale y usun mo liw przyczyn np za stawiona lub zas oni ta kratka wentylacyjna Kiedy urz dzenie sch odzi si w wysta...

Page 21: ...o servisem i srovnateln kvalifikovanou osobou vym n n POZOR K zabr n n p eh t nesm te topidlo zakr vat POZOR P stroj nepou vejte v prostorech s vanou sprchou nebo baz nem ani v bl zkosti d ezu nebo vo...

Page 22: ...pru iny na ka d stran sejm te n st nn dr k ze zadn strany za zen Vyvrtejte upev ovac otvory Dejte pozor na elektrick veden a potrub ve zdi P ilo en mi rouby n st nn dr k pevn p i rou bujte ke zdi Za...

Page 23: ...da je za zen zapnuto a termostat je nastaven na po adovanou teplotu zkontrolujte tak zda je zapnut automat v rozd len proudu resp zda je v po dku po jistka Pokud nelze poruchu odstranit kontaktujte ne...

Page 24: ...ww dimplex de esk DX410 DX415 DX420 DX425 DX430 Glen Dimplex Deutschland GmbH Am Goldenen Feld 18 D 95326 Kulmbach Technick zm ny vyhrazeny Telefon 49 9221 709 564 Fax 49 9221 709 589 E mail 092217095...

Reviews: