Dimplex DWF36 Owner'S Manual Download Page 7

 

7

  Fireplace Installation 

  

Quick Reference guide

  The electrical information 

regarding your electric fireplace 

can be found on the rating label 

located on the bottom of the unit, 

see above.

②  

Before installation, please 

record your fireplace's serial 

number above for future 

reference. The serial number can 

be found on the Model and Serial 

number Label of your fireplace.

  If you have any technical 

questions or concerns regarding 

the operation of your electric 

fireplace, or require service 

contact customer service. 

Site Selection

!

 NOTE:

 A 15 Amp, 120 

volt circuit is required. A 

dedicated circuit is preferred 

but not essential in all cases. 

A dedicated circuit will be 

required if, after installation, 

the circuit breaker trips or the 

fuse blows on a regular basis 

when the heater is operating. 

Additional appliances on the 

same circuit may exceed the 

current rating of the circuit 

breaker.

 CAUTION:

 

When the heater 

is in use, this product draws 

a high, continuous electrical 

current. not all electric 

receptacles are designed to 

work with high, continuous 

currents. If you plan on using 

this unit in an old, worn, 

or loose receptacle, or are 

unsure if the receptacle 

is suitable, please have it 

inspected by a qualified 

electrician prior to using this 

product.

 

WARNINg: 

Ensure the power 

cord is not installed so that 

it is pinched or against a 

sharp edge and ensure that 

the power cord is stored or 

secured to avoid tripping or 

snagging to reduce the risk of 

fire, electric shock or injury to 

persons.

Summary of Contents for DWF36

Page 1: ...this manual first before attempting to install or use this fireplace For your safety always comply with all warnings and safety instructions contained in this manual to prevent personal injury or prop...

Page 2: ...UTION Procedures and techniques which if not carefully followed will result in damage to the equipment Warning Procedures and techniques which if not carefully followed will expose the user to the ris...

Page 3: ...arranty Please record your model and serial numbers below for future reference model and serial numbers can be found on the Model and Serial Number Label of your fireplace NO NEED TO RETURN TO THE STO...

Page 4: ...trical or mechanical adjustment or repair Do not use outdoors Important Instructions This fireplace is not intended for use in bathrooms laundry areas and similar indoor locations Never locate heater...

Page 5: ...875 Watts Do not burn wood or other materials in the wall mount fireplace Do not strike the glass front Always use a certified electrician should new circuits or outlets be required Always use properl...

Page 6: ...ul interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful i...

Page 7: ...ted circuit will be required if after installation the circuit breaker trips or the fuse blows on a regular basis when the heater is operating Additional appliances on the same circuit may exceed the...

Page 8: ...wall mounted fireplaces only Improper use or use for purposes other than intended may cause damage or injury Installation WARNING Failure to install the fireplace as instructed below may result in da...

Page 9: ...apers clothes and curtains The wall mounting bracket 2 must be mounted to at least two 2 wall studs Studs should be accessed through two 2 wall bracket holes in one of the following combinations A C B...

Page 10: ...ote At least two of the mounting screws must be installed into a wall stud Remove the 2 screws 11 securing the firebox enclosure cover Figure 4 With the firebox tilted forward 12 carefully pour and ev...

Page 11: ...in the O position the fireplace is off B Three Position Switch The Three Position Switch changes the mode the fireplace operates in and has three 3 positions MANUAL OFF and REMOTE When in REMOTE mode...

Page 12: ...emperature cutoff switch can be reset by unplugging the unit waiting five 5 minutes and plugging the unit back in CAUTION If you need to continuously reset the heater unplug the unit and call Dimplex...

Page 13: ...ransmitter within that 10 seconds This will synchronize the remote control transmitter and receiver Remote Control Usage The remote control operates the fireplace levels sequentially from off flames o...

Page 14: ...an be removed by dusting lightly with a clean dry cloth To remove fingerprints or other marks the mirror can be cleaned with a damp cloth The mirror should be completely dried with a lint free cloth t...

Page 15: ...d by this limited warranty have been tested and inspected prior to shipment and subject to the provisions of this warranty Dimplex warrants such products to be free from defects in material and workma...

Page 16: ...removal of the product or part or any replacement product or part or any labour or transportation costs Such costs shall be the purchaser s responsibility What Dimplex and its dealers and service agen...

Page 17: ...sembly 2203540100RP On Off Switch 2800070200RP Remote Receiver 3000820100RP Switch Board 3000820300RP Flicker Rod 5902180100RP Cordset 4100190100RP Capacitor 2300030100RP LED Driver Board 3000810100RP...

Page 18: ...t rating Move the unit to another outlet or install unit on a dedicated 15 amp circuit Power cord gets warm 1 Normal operation 2 Improper extension cord in use 1 The power cord may get slightly warm t...

Page 19: ...rsists unplug unit and contact technical support Heater fan turns on but heater lacks heat 1 Improper operation 2 Normal operation 1 Refer to instruction manual 2 Normal operation 3 If problem persist...

Reviews: