background image

7

or tilting the heater do not block the 

exhaust opening.
The following steps are shown in 

Figure 3:
1. Locate a stud or other suitable

support and install hanger bracket 

on wall or ceiling. Select location 

so control knob on back of heater 

can be reached easily. * 

2. Insert carriage bolt into square

opening of heater handle.

3. Slide spacer over the carriage bolt

shaft and insert in hanger bracket 

opening and hold them in position.

4. Slide lock washer and thread nut

onto carriage bolt, turn and tighten 

with wrench. 

* DO NOT INSTALL LESS THAN 6

FT (1.9m) FROM THE FLOOR

ELECTRICAL CONNECTION

  

WARNING: 

 Consult local electri-

cal codes in addition to the follow-

ing requirements:

1. Turn off main power supply at the

electrical panel.

2. Route supply wires from circuit

breaker to an approved junction 

box, located near compact unit 

heater.  Each heater should be 

on an individual, properly fused 

circuit.

3. Route supply wires from junction

box to CUH.  Supply wires from 

junction box to heater must be two 

conductor metallic sheath (BX) 

  Heater Installation 

L1 

OFF

L2

CYCLE  

THERMOSTAT

M

ELEMENT

GROUND

R

OVER TEMP.

CUT-OUT

FAN DELAY

Wiring

cable with ground wire.  Alterna-

tively, appropriate conduit can be 

used.

4. Remove junction box cover of

CUH and remove one knockout 

hole.  Insert approved bushing 

into hole and feed wire cable 

through.  Tighten bushing around 

cable.

5. Make electrical connection to

CUH according to relevant wire 

diagram.  Make connections using 

approved wire nut connectors 

and secure the grounding wire to 

the ground screw on the heater 

chassis.

!

 NOTE: 

The onboard thermostat

can be bypassed, to allow for opera-

tion with a wall mounted thermostat. 

To do this disconnect the wires from 

the onboard thermostat and join them 

with a wire connector.
6. Replace junction box cover of

CUH.

Summary of Contents for CUH02B31T

Page 1: ...INFORMATION Always read this manual first before attempting to install or use this heater For your safety always comply with all warnings and safety instructions contained in this manual to prevent pe...

Page 2: ...size CAUTION Procedures and techniques which if not care fully followed will result in damage to the equipment WARNING Procedures and techniques which if not care fully followed will expose the user t...

Page 3: ...anty Please record your model and serial numbers below for future reference Model and serial numbers can be found on the Model and Serial Number Label of your heater NO NEED TO RETURN TO THE STORE Que...

Page 4: ...laundry areas and similar indoor locations Never locate heater where it may fall into a bathtub or IMPORTANT INSTRUCTIONS other water container Connect to properly grounded power source only To disco...

Page 5: ...nect all power supplies be fore performing any cleaning mainte nance or relocation of the heater When transporting or storing the heater keep in a dry place free from excessive vibration and store so...

Page 6: ...discharge is parallel to or away from walls NOTE To prevent personal injury always use a licensed electrician to install new outlets or circuits CAUTION When turning and or tilting the heater do not b...

Page 7: ...n box located near compact unit heater Each heater should be on an individual properly fused circuit 3 Route supply wires from junction box to CUH Supply wires from junction box to heater must be two...

Page 8: ...pe dry with a dry cloth DO NOT re energize unit until it has dried thoroughly Operation WARNING This heater must be properly installed before it is used Setting the Thermostat 1 Before connecting or d...

Page 9: ...s warranty The Company s only obligation under this warranty will be at its sole option to repair or replace any part proving defective or to refund the purchase price thereof The owner user assumes a...

Page 10: ...d 1367 Industrial Road Cambridge ON Canada N1R 7G8 Fan Blade 5300220100RP Motor Kit 2000260300RP Element 5000W 2200070622RP 4000W 2200070922RP 3000W 2200070822RP 2000W 2200070722RP Thermostat 26000606...

Page 11: ...ire le pr sent manuel avant d essayer d installer ou d utiliser ce radiateur Pour votre s curit toujours respecter tous les avertissements et suivre les consignes de s curit compris dans le pr sent ma...

Page 12: ...tes pour qu on les souligne MISE EN GARDE Marches suivre et techniques dont le non respect pourrait causer des dommages mat riels AVERTISSEMENT Marches suivre et techniques qui si elles ne sont pas bi...

Page 13: ...ne consultation ult rieure les num ros de mod le et de s rie se trouvent sur l tiquette du num ro de mod le et du num ro de s rie Num ro de mod le IL N EST PAS N CESSAIRE D ALLER AU MAGASIN Des questi...

Page 14: ...le faire v rifier pour faire effectuer une mise au point lectrique ou m cani que ou pour le faire r parer com INSTRUCTIONS IMPORTANTES muniquer avec un centre de service autoris Ne pas utiliser l ext...

Page 15: ...t et autres mati res combustibles moins de 0 9 m tre 3 pieds du devant de l appareil EMPLACEMENTDEL A ROTHER MEETD GAGEMENT EST ALLUM Toujours faire appel un lec tricien certifi pour l installation de...

Page 16: ...ion au plafond ou au mur n est pas comprise MISE EN GARDE Au moment de tourner et ou d incliner l appareil s assurer de ne pas bloquer la sortie d air Les tapes suivantes sont illustr es la FIGURE 3 1...

Page 17: ...se la terre Autrement il est aussi possible d utiliser un conduit de c bles appropri 4 Retirer le couvercle de la bo te de raccordement de l a rotherme compact et retirer l une des en tr es d fon able...

Page 18: ...il ne soit compl tement sec Figure 4 Bouton de commande du thermostat Utilisation AVERTISSEMENT Ce radiateur lectrique doit tre install correcte ment avant son utilisation R GLAGE DU THERMOSTAT 1 Avan...

Page 19: ...La seule obligation de Dimplex au titre de la pr sente garantie consiste r parer ou remplacer toute pi ce d fectueuse ou rembourser l acheteur le prix d achat de l appareil et ce sa seule discr tion L...

Page 20: ...rial Road Cambridge ON Canada N1R 7G8 La lame du ventilateur 5300220100RP Kit de moteur 2000260300RP l ment 5000W 2200070622RP 4000W 2200070922RP 3000W 2200070822RP 2000W 2200070722RP Thermostat 26000...