background image

The product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic  Compatibility
(EMC) EN55014, EN60555-2 and EN60555-3 which cover the essential requirements of EEC Directives 73/23 and 89/336

 

Glen Dimplex UK Limited

UK customer help line (8.00AM – 6.00PM Mon-Fri; 8.30AM-1.00PM Sat)

Millbrook House
Grange Drive

Customer Services:       Tel.    0870 7270101

Hedge End

           Fax.    0870 7270102

Southampton

          e-mail     [email protected]

Hampshire.  SO30 2DF

Republic of Ireland         Tel.   01. 8424833

Installation

Before undertaking installation work, ensure the electricity supply is
disconnected from any relevant fixed wiring. Supply cable is not supplied
with this appliance and it should therefore be installed by a competent
electrician in accordance with the IEE wiring regulations.

The supply circuit must be adequate for the input of the appliance and
must be protected with a 13A fuse.
A suitable termination to the fixed wiring of the premises must be provided
adjacent to the final position of the appliance through a double pole
switch having a contact separation of at least 3mm in all poles.

Installation Procedure

It is essential to observe minimum wall mounting clearances, as per
Fig. 1 overleaf.
The appliance should be fitted horizontally, with the cable entry at the
top and grille at the bottom. It must be mounted not less than 1.8 metres
above the floor with a clearance of at least 600mm to any shelf or
projecting surface below the heater and not less than 280mm below the
ceiling or other projecting surface. It must also be not less than 250mm
from an adjacent projecting surface. For most effective heating
performance, the heater should be mounted at the minimum height :-

i.e.- 1.8 metres above the floor.

Care must be taken to ensure that when in use, the air stream is not
obstructed by a high shelf or cabinet.

The appliance is secured to the wall with three screws, two through
keyhole slots and one through a centrally positioned lower hole to hold
the appliance firmly in position (see Fig 2).

1.

Remove the top cover from the appliance by removing the two
screws securing the top cover and hinging it back.

2.

Mark the position of the keyhole slots on the wall and drill and plug
for the two suitable screws.

3.

Partially insert the two screws, then hang the appliance on these
screws and mark the position of the lower centrally positioned screw.

4.

Remove the appliance and drill and plug for the third screw.

5.

Remount the appliance on the wall, ensure that it is horizontal and
fix in position by tightening all three screws.

6.

Feed the supply cord or wires through the inlet at the top rear

 

of

the appliance leaving sufficient free length to connect to the terminal
block.

7.

Make electrical connections to the terminal block ensuring that the
live connection is made to the terminal marked ‘L’ and the neutral
connection to the terminal marked ‘N’ (see Fig 2 exploded view).

8.

Operate the selector switch to provide either 1kW or 2kW output.

9.

Replace the top cover and screws.

The appliance is now ready for use and the electricity supply can be
reinstated.

Cable entry

Hole for

3rd Screw

L

C

95

2 No.

Slots

Keyhole

188

116

22

72

Exploded view of 

Terminal Block

Terminal

Block 

L

N

Mains Cable 

Fig. 2

Cleaning and User Maintenance

WARNING

BEFORE UNDERTAKING CLEANING OR MAINTENANCE WORK ON
THE APPLIANCE IMMEDIATELY DISCONNECT THE ELECTRICITY
SUPPLY BY SWITCHING OFF AT THE ADJACENT DOUBLE POLE
SWITCH.

The outside can be cleaned by wiping it over with a soft damp cloth and
then dried. Do not use abrasive cleaning powders or furniture polish as
this can damage the surface finish.

After Sales Service

Your Chilton  downflow fan heater is guaranteed for one year from the
date of purchase. We undertake to repair or exchange free of charge
within this period, any part found to be defective due to a manufacturing
fault.

Should you require after sales service, please get in touch with the supplier
through whom you purchased the appliance, or your nearest  Customer
Services.

Please do not initially return a faulty appliance or part of an appliance to
us as this may result in transit damage and/or delay in providing service.
Let us know your difficulty quoting the model number and series letter of
the appliance. We will then take the appropriate action.

Please retain receipt as proof of purchase.

CHDF20 High Level Wall
mounted

The heater is fitted with a pull cord operated
ON/OFF switch, a thermostat, a cut-out,
and a thermal fuse link.
The heater has an external adjustable
thermostat which can be adjusted by user
(i.e. by turning the knob to the side of the
heater), see Fig 3 for controls details.
Temp. range 18°C - 32°C.

'External' Adjustable
Thermostat Knob

Selector

Switch

L

N

Fig. 3

CHDF20 WIRING DIAGRAM