Dimplex AX2 User Manual Download Page 5

double pole heater switch wall mounted in  

accordance with local authority regulations 

seperate permanently

connected supply

from consumer unit

Dimplex electric

water heater

cold

water

mains

supply

isolating

stop tap 

SECTION 3

General layout of a  
shower installation

INSTALLATION

SECTION 4

Installation

Position your shower unit on the wall away 
from the direct spray of the shower and at 
about the same height as the shower head 
position.

The shower unit should be positioned so that 
the shower head cannot be immersed in the 
bath or shower tray when hanging down.

Shower unit can be mounted

either side of riser rail

Outline of bath

or shower tray

Spillover

level

Spillover

level

Mains cold water supply

(either top, bottom 

or rear entry)

Height of sprayhead

and shower to suit 

user’s requirements

Soap dish

A TYPICAL INSTANTANEOUS ELECTRIC SHOWER 
INSTALLATION

4

Plan your own installation carefully. Check on 
the nearest and most readily accessible rising 
mains water supply, this may be beneath the 
bath or in the loft, where it feeds the cold 
water storage tank. Use only the cold rising 
water main supply. 

Do not connect the shower unit to the 
down service from the tank.

Avoid connecting the shower unit, if possible, 
were it will be affected by water drawn off by 
other appliances, e.g. From the mains feed to 
the W.C., This may cause a drop in pressure 
too low for the shower unit to work correctly.

An isolating valve must be fitted into the water 
supply for servicing purposes.

Remove the two screws securing the shower 
unit cover and remove the cover complete with 
the control knobs.

Place the shower unit on the wall and mark the 
location of the fixing screws through the back 
plate.

Carefully drill the holes as marked using a 
sharp 5.5mm masonry drill.

Fix the shower unit to the wall using the plugs 
and screws provided, do not fully tighten at 
this stage.

OPERATING INSTRUCTIONS 

‘High’

 setting 

(Solid Red Symbol)

:

This is the full power setting. 
Temperature adjustment is via the 
bottom temperature control.

4.  Wait a few seconds for the warmer water to 

reach the handset.

5.  If necessary turn bottom 

‘Temperature’

 

control knob slowly to obtain desired 
showering temperature. Again, waiting 
a few seconds after each adjustment in 
temperature to reach the handset.

Note:

 

To adjust the shower temperature.

 

The water temperature is altered by 
increasing or decreasing the flow rate 
of water through the shower unit via the 
temperature control.

To increase the shower temperature

Turn the temperature control knob 
clockwise, this will decrease the flow 
of water and increase the shower 
temperature.

To decrease the shower 
temperature

Turn the temperature control knob 
anti-clockwise, this will increase the 
flow of water and decrease the shower 
temperature.

6.  Turn the top power selector knob to the 

STOP/START

 position (

Outline Grey 

Symbol

) to stop the flow.

7.  A small amount of water will be retained 

in the shower head after the shower has 
been turned off. This may drain over a few 
minutes.

8.  Switch off pull-cord or wall mounted switch.

9

COOLER

WARMER

COLD

LOW

HIGH

AX2 12pg booklet printers spread8-9   8-9

13/8/07   2:16:18 pm

Summary of Contents for AX2

Page 1: ...h may be of use to you and is available 24 hours a day It includes Operating and installation instructions Easy How to use guides for storage heaters Service and repairs Where to buy our products Literature downloads Heating requirement calculator Visit www dimplex co uk support A division of GDC Group Ltd Millbrook House Grange Drive Hedge End Southampton SO30 2DF www dimplex co uk Registered No ...

Page 2: ...ax 01489 773053 GUARANTEE Dimplex UK Limited guarantee this Dimplex product for a period of two years from date of purchase against mechanical and electrical defects arising from faulty materials or from poor workmanship providing the product has been installed by a competent person in accordance with the fitting instructions Dimplex UK Limited undertake to repair or replace at their discretion wi...

Page 3: ...w power Water too cool or cold Water flow too high Reduce flow rate via temperature control Water pressure below minimum required See rating label Check water supply Reduction in ambient water temperature Select High power Water flow is poor Shower head is blocked Clean the showerhead Ensure showerhead is as specified by manufacturer The temperature control knob is set at its hottest setting Incre...

Page 4: ...o a tank supply unless a suitable booster pump is fitted 3 The minimum recommended running water pressure to which the shower heater may be connected is 15 lb sq in 1 Bar Running pressure at 8 litres per minute The maximum static pressure recommended is 150 lb sq in 10 Bar 4 The shower unit must not be fitted where it may be exposed to frost for example in an outdoor shower area The shower must no...

Page 5: ...y for servicing purposes Remove the two screws securing the shower unit cover and remove the cover complete with the control knobs Place the shower unit on the wall and mark the location of the fixing screws through the back plate Carefully drill the holes as marked using a sharp 5 5mm masonry drill Fix the shower unit to the wall using the plugs and screws provided do not fully tighten at this st...

Page 6: ...h the shower head NOTE When the temperature is changed the flow rate alters 11 Turn the top power selector knob to the STOP START position Outline Grey Symbol to stop the flow COMMISSIONING THE SHOWER OPERATING INSTRUCTIONS SECTION 10 Operating the shower 1 Switch on pull cord or wall mounted switch The Power neon will illuminate indicating the switch is on 2 Turn the top power selector knob to th...

Page 7: ...IMPORTANT Ensure that the terminal block screws are fully tightened and that no cable insulation is trapped under screws Ensure the cable clamp is used to secure the cable The earth continuity conductor of the electrical installation must be effectively connected to all SECTION 7 Fitting the cover into position NOTE It is necessary to align the D flat on the reverse side of the Power Selector and ...