Dimplex AWP 300 LW Installation And Operating Manual Download Page 13

Page 13 of 

20

 

10. 

Decommissioning

 

 

Activities to be performed: 
 

• 

Disconnect HPWH from the power source. 

• 

Completely shut off water circuit (hot water, cold water and circulation line) and drain the hot water stor-
age tank. 

 
 
 

11. 

Environmental Requirements

 

 

Environment-relevant requirements regarding the recovery, reuse and disposal of service fuels and compo-
nents in accordance with DIN EN 378 must be adhered to when repairing or decommissioning the HPWH. 

 

12 Appendix 

 
12.1  Refrigeration Cycle with Legend 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Compressor 

Temperature control, heat pump 

15 

Evaporator 

 

Pressostat HP 

Safety temperature limiter 

16 

Fan 

 

Condenser 

10 

Temperature control, immers. heater  17 

Check valve 

 

Hot water tank 

11 

Temperature display 

18 

Insulation 

 

Heat exchanger (not all types) 

12 

Filter drier 

 

 

Immersion heater 

13 

Expansion valve 

 

 

Sacrificial anode 

14 

Air temperature thermostat 

 

TC

13

18

16

15

14

1

18

12

2

3

 7

4

 6

11

10

  9

  8

PA-CO-H

TI-CO-L

TI-CO-H

TI

-CO-H
-C I -L

TI

TI

-CO-H
-C I -L

free immersion well

17

Summary of Contents for AWP 300 LW

Page 1: ...451901 67 19 FD8405 Installation and Operating Manual Heat Pump Water Heater with Sheet Metal Cabinet Airduct Connection and Supplementary Heat Exchanger AWP 300 LW...

Page 2: ...ter Piping 9 6 2 Connection of Condensate Line 9 6 3 Electrical Connection 9 6 3 1 Opening the Cabinet 10 7 Commissioning 10 7 1 Hot Water Circuit 10 7 1 1 Hot Water Circuit Requirements 10 7 1 2 Comm...

Page 3: ...e ready for connection and essentially consists of a domestic water tank the components of the refrigeration air and water circuits as well as all control regulating and monitoring devices required fo...

Page 4: ...d part of the heat of the compressor motor is transferred to the water Subsequently the high condensing pressure is reduced by means of a throttling device expansion valve to the level of the evaporat...

Page 5: ...located in the well of the immersion heater When the preset switching value 99 C is exceeded the immer sion heater is switched off The immersion heater cannot be restarted unless the hot water tempera...

Page 6: ...ging pump of an additional heat ex changer to be activated via the Heat exchanger relay output In this case the Heat exchanger switch must be in the On position 3 4 Immersion Heater Switch The integra...

Page 7: ...ransport over short distances and provided due care is exercised an inclination angle of up to 45 is permitted Both during transport and storage ambient temperatures of 20 to 70 C are permissible 4 1...

Page 8: ...ly by means of insulated airducts NW 160 which must not exceed a total length of 10 m If the ceiling is lower and no airducts are used an air ducting elbow 90 NW 160 must be used on the outlet air sid...

Page 9: ...ithout pressure is provided which must also be relocated when the condensate hose is shortened valve can be easily removed and reinstalled on the hose 6 3 Electrical Connection The HPWH is pre wired r...

Page 10: ...ise and remove 4 To remove the bottom front panel 4 only required for checking the sacrificial anode or the immersion heater it suffices to loosen the lower two fastening screws d and to slide the bot...

Page 11: ...may still be rotating General No maintenance activities need to be performed on the refrigeration circuit of the heat pump For cleaning the HPWH simply use a damp cloth and some soapy water Caution D...

Page 12: ...es that are impaired in their function will reduce the life of the unit 9 Malfunctions Troubleshooting intended for the user Caution Work on the heat pump water heater may only be performed by qualifi...

Page 13: ...dhered to when repairing or decommissioning the HPWH 12 Appendix 12 1 Refrigeration Cycle with Legend 1 Compressor 8 Temperature control heat pump 15 Evaporator 2 Pressostat HP 9 Safety temperature li...

Page 14: ...2 2 2 Heat Exchanger Plumbing Diagram Example Thermal Solar System Heat exchanger flow Heat exchanger return hot water heating water supply circulation if required heating water return cold water conn...

Page 15: ...K4 M 1 M 2 S1 S2 S3 X1 X2 X3 X5 Legende 2 S1 1 T B1 2 27 55 C Verdichter Ventilator X5 6 X5 7 Pot freier Kontakt f r Heizstabanst 230V AC m in 8A PE 4 5 A2 A1 K1 11 14 X5 2 1 S3 K4 11 14 K4 A1 A2 5 H1...

Page 16: ...C Watt 550 Average heat output 1 at 45 C Watt 1830 COP t as per EN 255 at 45 C 3 4 Sound pressure level 3 dB A 53 Air flow rate m3 h 450 External pressure Pa 100 Maximum airduct connection length tota...

Page 17: ......

Page 18: ...Page 18 of 20...

Page 19: ...Page 19 of 20...

Page 20: ...Page 20 of 20 KKW Kulmbacher Klimager te Werk GmbH Subject to technical modifications Division Dimplex Fax 0 92 21 709 589 Am Goldenen Feld 18 www dimplex de D 95326 Kulmbach...