MAXI CONTROLLER EVO 1.2

Installation and User Guide

Summary of Contents for MAXI CONTROLLER EVO 1.2

Page 1: ...EN LET THERE BE LIGHT DIMLUX DIMLUX NL DimLux is a registered trademark of airSupplies MAXI CONTROLLER EVO 1 2 Installation and User Guide ...

Page 2: ...an also operate the lighting in two rooms in turns This requires a second temperature sensor which can be connected to port RH T2 The relative humidity sensor will no longer be required The controller is modular All sensors can be purchased independently according to need Components The controller The controller regulates and operates the lighting CO2 VPD status and any other connected components ...

Page 3: ...ted in the 2nd controller using the mode button The 1st controller is set to the normal function on off timer countdown using the mode button double core cables Older models ballasts or light fixtures without Interlink connections can also be controlled with the EVO 1 2 The green connector beneath the OUT ports can be used for this Here up to 40 ballasts or light fixtures can be connected per port...

Page 4: ...g this key the menu is opened in order to change settings Basic light menu The following parameters can be set in the basic light menu Current time Timer ON OFF Type of ballast light fixture Time Time 05 51 Press the SET key briefly the current time will appear By pressing the SET key again the time can be set using the or key Pressing the ESCAPE key will return you to the Home screen Timer ON OFF...

Page 5: ...ifferent sensors can be displayed including when the maximum minimum event has occurred Events alarm log Here you can see when and why the controller has intervened PLUS key You can browse or increase the values by pressing this key briefly and repeatedly MIN key You can browse or decrease the values by pressing this key briefly and repeatedly SET key Using this key the menu is opened in order to ...

Page 6: ...key is pressed Using the and keys opt for always ON or AUTO OFF and confirm with SET Temperature display Temperature in Celsius Here you can select the temperature display in either Celsius or Fahrenheit Press on the SET key and using the and keys select Fahrenheit or Celsius and confirm with SET Output display Output display in Watt You can select to display the status of dim boost in the Light s...

Page 7: ... Advanced aux fan menu Eight parameters can be set in the advanced fan menu in order to ensure that the installation works as efficiently as possible Temperature RH Day RH Night Max fan speed Day Max fan speed night Min fan speed De aux setting Heat De aux setting RH Press SET once and use the and keys to select the above options Press SET once more to change these parameters The fan mode can be c...

Page 8: ...th Advanced VPD menu AT 29 2 RH 60 2 PT 22 8 VPD 1 10 You can read the room temperature AT relative humidity RH plant temperature PT delta T DT and the VPD value on the VPD display screen You can switch between PT and DT by pressing the and keys in this screen PT is the plant temperature measured with the plant temperature camera Delta T indicates the difference between AT and PT The difference be...

Page 9: ...ghest and lowest plant temperature including the time are displayed MENU KEYS MENU KEYS ERROR EVENTS CO2 high low H CO2 391p 13 15 L CO2 184p 13 13 The highest and lowest CO2 value including the time are displayed The high low values can be reset by pressing the SET key in this screen and by using the and keys to select Reset Yes The high low values are always reset every day at 00 00hr By pressin...

Page 10: ...on HTP High temperature safeguard active Off Rem Lamp off with maxi controller HVP Too high voltage power supply Off Rem Lamp on with maxi controller HVP Too low voltage power supply Open Open contact between the ballast and lamp or defective lamp EOL Life expectancy of lamp DATALOG AND DIMLUX CONNECTION OPTIONS Interlink cable The new EVO Maxi Controller 1 2 has a new simpler system to connect th...

Page 11: ... Maximum 80 light fittings per OUT port provided that the original cables are used 1 2 3 4 5 6 Other options for use in existing or older systems 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 CONNECTION OPTIONS NOTES 6 6 6 ...