background image

Aquatic Fitness System 

2003

 

Owner’s Manual

 

 

Special Cold Weather Instructions 

Slipping into your steamy water on a snowy, winter night is a refreshing experience. Many times, people who 
could never imagine being outside in winter weather, find themselves spending their winter nights

 

doing just 

that, while relaxing in their spa with family and friends. Therefore, the best winterizing tips of all are to enjoy 
use of your system year-round

.

 

 

All systems manufactured by Dimension One Spas are designed for rigorous winter use. They are insulated to 
keep operating costs down and to protect plumbing and equipment whenever the products are operational. 
Each product line incorporates freeze protection mode to maintain water circulation during freezing 
conditions whenever the system has proper electrical power and water level. Therefore, a fully operational 
system is your number one defense against freeze damage.

 

 

If you find it completely necessary to drain your water during the winter months, in an area where freezing 
conditions may exist, please adhere to all of the instructions in this section to minimize the risk of freeze 
damage. Failure to complete any of the steps satisfactorily will increase the chance of freeze damage, as small 
amounts of water trapped in pipes will expand as it freezes, and may result in damaged plumbing lines or 
fittings. 

 

 

 

 

 
Dimension One Spas does not recommend that you drain your system

 f

or the winter. 

Freeze damage is specifically not covered by Your Warranty. 

 

Items Required for Winterizing

 

• 

Phillips head screwdriver 

• 

16” Channel-lock pliers 

• 

High pressure air blower

 

• 

Commercial grade wet-vacuum 

• 

3 to 6 gallons (11.4 to 22.7 liters) of Non-Toxic Antifreeze 

• 

Strong, able-bodied people capable of lifting system into upright position 

• 

Enough time (and patience) to perform all steps. 

Procedure for Winterizing 

1.  Shut the power off to the system and make sure that it cannot be accidentally turned back on.  

 

2.  Remove filter elements from filter assembly. 

 

3.  Drain water from the system using the drain fitting and garden hose or you may use a submersible 

pump for faster draining. 

 

4.  Open the equipment compartment and locate pumps and heater. 

 

5.  Remove all of the drain plugs from each pump. 

 

6.  Loosen unions on both sides of each pump, and the heater if applicable.  

 

7.  If your system has a Dynamic Jet Sequencer, please remove that access panel as well and loosen all 

unions on each of the sequencer valves.  There are 6 sequencer valves, which means that you will 
have to loosen 12 unions. 

 

8.  Tip the system onto one side – spas only, not Aquatic Fitness System. (The system will have 

some water remaining, which will add to the weight). Be sure to have enough people available to 
safely lift the weight of your system. Do not tip system onto equipment bay side.  

28  

 

Summary of Contents for AQUATIC FITNESS SYSTEM 2003

Page 1: ......

Page 2: ...Aquatic Fitness System 2003 Owner s Manual ii...

Page 3: ...10 Using The Top Side Control 10 Temperature Set Buttons 11 Jets 1 Button 11 Jets 2 and Jets 3 Buttons 12 Light Button 12 LED Display Window 12 Programming the Filtration Cycle 13 Filtration 13 Filter...

Page 4: ...it Dual Temp Pool Side Only and AquaPro 25 LIGHT BULB REPLACEMENT 26 SURFACE CARE SHELL 27 Dimension One EnviroTect Skirts and Vinyl Covers 27 Care for the Wood Spa Cabinet 27 SPECIAL COLD WEATHER INS...

Page 5: ...y paralysis or death can occur if user jumps of dives into the Aquatic Fitness System The Aquatic Fitness System is not designed for jumping of diving Extreme caution must be exercised to prevent anyo...

Page 6: ...al use will exceed 10 minutes or anytime young children are present in the Aquatic Fitness System To Reduce the Risk of Injury Prolonged immersion in an Aquatic Fitness System may be injurious to your...

Page 7: ...use Aquatic Fitness System To Reduce the Risk of Injury Wet surfaces can be slippery To avoid injury exercise care when entering or exiting the Aquatic Fitness System To Reduce the Risk of Injury Mai...

Page 8: ...the normal body temperature of 98 6 F or 37 C The symptoms of hyperthermia include dizziness drowsiness lethargy and fainting The effects of hyperthermia include Failure to perceive heat Failure to re...

Page 9: ...tem cover closed when the Aquatic Fitness System is not in use This is also the key to economical Aquatic Fitness System operation Don ts DON T allow horseplay or unsupervised use of your Aquatic Fitn...

Page 10: ...e to all who use your Aquatic Fitness System This sign must be permanently placed in a location that is visible to the Aquatic Fitness System user Replacement signs may be obtained from Dimension One...

Page 11: ...HydroSport Aquatic Fitness Gear The HydroSport Swim System is included with the Aquatic Fitness System This Swim System includes the Swim Tether six high volume Swim Jets and a Swim Kick Bar You may...

Page 12: ...e Swim Tether at the other end Built in OptiMounts Multiple OptiMount locations are installed to provide easy installation of the HydroSport Aquatic Fitness Gear components Multiple Training Stations...

Page 13: ...heater equipped with a high limit temperature safety shut off switch The high limit switch automatically shuts the heater off when the temperature reaches 118o F If the high limit safety switch trips...

Page 14: ...ystem should be filled until the water level is approximately 2 inches 5 centimeters above the bottom of the tile line Do not attempt to use your Aquatic Fitness System until your dealer has completed...

Page 15: ...n the UP and DOWN Arrow Buttons will light up while the heater is on and flash when there is a call for heat and the heater has not yet been activated Jets 1 Button JETS 1 Button Press the button once...

Page 16: ...ff if any of the pumps are operated at high speed If you are running a separate 50 amp service for heat and a separate 50 amp service for the pumps you can continue to heat your water while operating...

Page 17: ...e the WARMER and COOLER buttons to scroll up or down between the filtering modes The filter cycles are as follows Standard Mode F1 F2 F3 Economy Mode F4 F5 F6 Lockout Mode L1 L2 Standard Mode and Econ...

Page 18: ...you don t make another change within three 3 more seconds Set the display to F2 to receive two 2 hours of filtration three times a day To select filter cycle F2 press and hold the Warmer and Cooler B...

Page 19: ...er change within three 3 more seconds Set the display to F5 to receive two 2 hours of filtration and heat three times a day To select filter cycle F5 press and hold the Warmer and Cooler Buttons for t...

Page 20: ...control is heating when the system is put into the lockout mode the heater will immediately turn off and the pump will cycle water for thirty seconds then turn off This will assist in cooling the heat...

Page 21: ...systems Water level referencing weir skimmer Proportional FastFlo Heater A variety of interchangeable jets Exclusive custom hand set ceramic tile adds a distinctive touch Built in automatic freeze pro...

Page 22: ...ontrol Temperature setting jet power control and the hot tub light are all spa side accessible That means you don t have to get out of the hot tub to enjoy complete control of all hot tub functions Sa...

Page 23: ...ly activated during a heating cycle in which case a third press will return the pump to the Low Speed The Jets Indicator Light next to the Jets Button will be lit while the pump is running A Jet Pump...

Page 24: ...ght Button is used to turn the Dynamic L E D Light ON or OFF and manage the custom lighting sequences Up and Down Buttons Up and Down Buttons Pushing the UP Button increases the temperature and pushin...

Page 25: ...WN buttons to change to the correct MINUTES When the MINUTES are correct press the LIGHT Button to toggle the AM PM Filter Cycle Start Time Program the Filter Cycle Start Time by pressing the PROGRAM...

Page 26: ...ter temperature simply use the UP or DOWN Buttons to select between Fahrenheit F and Celsius C The factory default setting is Fahrenheit Exit the Programming Sequence by pressing the PROGRAM Button a...

Page 27: ...igh limit condition The water temperature has reached 118 F 47 8 C The entire system is disabled Contact your local Authorized Dimension One Spas Dealer or authorized service center DO NOT ENTER THE W...

Page 28: ...shing Temperature on the Display DO NOT ENTER THE WATER if you see a flashing temperature of 34 F or 134 F The system has detected a Temperature Probe Failure Contact your local Authorized Dimension O...

Page 29: ...y extended Hold the centerpiece of the assembly and turn it counter clockwise until the flats of the basket are aligned with the securing tabs Then pull the basket assembly straight up to remove Next...

Page 30: ...the light housing cover without lowering the water level below the light housing cover Do not attempt to remove the light housing cover without the special tool If you are not able to locate it contac...

Page 31: ...yl Covers The Dimension One EnviroTect skirts are unaffected by most corrosive substances and will not absorb moisture To maintain the original finish clean with soap and water No sealing or painting...

Page 32: ...as it freezes and may result in damaged plumbing lines or fittings Dimension One Spas does not recommend that you drain your system for the winter Freeze damage is specifically not covered by Your Wa...

Page 33: ...from the filter canister Repeat this process with the front most bleeder fitting Confirm that water mist is blowing from the drain fittings of the jet pumps 14 Place the hose of a commercial grade wet...

Page 34: ...n tarp the system at this point for maximum protection Spring Time Startup In the spring or when you are ready to start the system back up follow these instructions Make sure o rings for pumps are in...

Page 35: ...d up high enough Maximum thermostat setting is approximately 104 F 40 C 3 Burned out Aquatic Fitness System light Bulbs are not covered 4 Aquatic Fitness System water chemistry is the responsibility o...

Page 36: ...tronic control system that governs all of the electrically operated components of your Aquatic Fitness System utilizes an advanced microprocessor and solid state electronic switches to activate all us...

Page 37: ...ice s that sends a signal to the electronic control system that there is adequate water flow to turn the heater on Primary Pump Produces water flow through the heater filter sanitation system and the...

Page 38: ...jet pumps are single speed pumps that operate on high speed The second and third pump buttons control the booster pumps Temperature Sensor Measures the temperature of the water inside the Aquatic Fit...

Page 39: ...uts down unexpectedly while in use 2 Motor over heated and automatic protective device has shut down pump s 2 If pump s will not restart when JETS pad is pushed call for service Make sure that the equ...

Page 40: ...k for proper water level ensure pump is primed and or check for clogged filter Pressure switch may need to be adjusted Call the dealer for service Pressure switch problem Pressure switch is closed whi...

Page 41: ...erature Condition Do not enter spa water The water temperature is above acceptable limits The water temperature has reached 110 F 43 3 C The system will shut down 1 Remove the cover and allow the wate...

Page 42: ...003 Owner s Manual Symptom Cont Problem Corrective Action Temperature Probe Failure If the LED Digital Display shows 34 F or 134 F you have an Open temperature sensor The heater is deactivated Call th...

Page 43: ......

Page 44: ......

Reviews: