10
Typically not used.
Typically not used.
Filter values (damping factors) on the load cell signal. Acceptable
values are from 0 (no damping) to 7 (maximum damping).
Changes the serial communication link between RS-485 and radio
link. Press F + TEST key to toggle between the two choices. Select
RS-232 communication by depressing F+ON/OFF at power up and
RS-485 and radio will be bypassed.
The communication address assigned to the device in multidrop
applications. Values should be between 33 and 255.
Communication baud rate. Available values are 300, 1200, 2400,
4800, 9600, and 19,200 baud. System default is 2400 baud. Radio
communication at 2400 baud by default.
SEt-1**
SEt-2**
FiLt
SErch*
Addr*
bAud*
Label
Typical Display
Description
100
110
2
rS-485
rAdio
100
2400
*
Change takes effect only after the unit has been switched off and then back on.
**
Used only in special software applications
Table 5
Configuration Items
Sleep mode is a non-configurable battery saving feature of the ED-2000plus. It
functions all the time. If signal changes from the strain gages are not received
by the microprocessor, certain high drain functions are shut down. The
display does not change and any communication with the unit or signal from
the gages reactivates the unit instantly. The function of the sleep mode is
transparent to the user.
The ED-2000plus software allows you to use the Radio-Link option. If the
Radio-Link option is installed but not being used, disable the radio portion of
the software to increase battery life. Also, if your system is not equipped with
the Radio-Link option, disable the software.
To disable the Radio-Link software see the
SErch
section in Table 5 below.
Notice that the change will not take effect until the ED-2000plus has been
switched off and then back on.
Disabling the Radio-Link
Software to Save Battery
Power
Sleep Mode