background image

The PD does not operate: 

 

Verify that the PoE Injector detects a PD. 

 

Verify that the PD is designed for PoE operation. 

 

Verify that you are using a standard Category 5/5e/6,  

straight-wired cable, with four pairs. 

 

If an external power splitter is in use,  

replace it with a known-good splitter. 

 

Ensure input Ethernet cable is connected to the DATA IN port. 

 

Verify that the PD is connected to the Data & Power port. 

 

Try to reconnect the same PD into a different PoE Injector.  

If it works, there is probably a faulty port or RJ45 connection. 

 

Verify that there is no short over any of the twisted pair cables or 

over the RJ45 connectors. 

 

The end device operates, but there is no data link: 

 

Verify that the port indicator on the front panel is continuously lit. 

 

If an external power splitter is in use, 

replace it with a known-good splitter. 

 

Verify that for this link, you are using standard UTP/FTP Category 5 

straight (non-crossover) cabling, with all four pairs. 

 

Verify that the Ethernet cable length is less than 100 meters from the 

Ethernet source to the load/remote terminal. 

 

Try to reconnect the same PD into a different PoE Injector If it works, 

there is probably a faulty port or RJ45 connection 

 

 

Reviews: