background image

7.2 Din rail installation 

The first step is to check the grounding and stability of the guide rail: 

the guide rail slot of the switch is clamped into the guide rail; The 

second step: from the center to both sides of the guide rail positioning 

screws in order. Step 3: 

Use screws to fix the mounting rail card slot 

on the fixed guide groove at both ends of the guide rail to ensure that 

the guide rail and the switch are fixed on the guide rail vertically and 

stably. 

 

 

7.3 Grounding 

Fix the grounding wire to the grounding screw above the switch and 

ensure good reliable connection of the grounding system. 

 

7.4 Power Connection 

Insert the power cord into the specified position of the 6-core 

terminal, and insert the terminal into the standard power supply inlet 

(P+1 and P-1 input corresponding to the first power supply P1, and P+2 

and P-2 input corresponding to the second power supply P2). The 

available voltage standard of the power supply is supported from 

12VDC to 52VDC 

Summary of Contents for DN-651129

Page 1: ...INDUSTRIAL 16 PORT GIGABIT SWITCH UNMANAGED Quick Installation Guide DN 651129 ...

Page 2: ...s housing and LED indicator light make the DN 651129 a plug and play industrial grade device providing a reliable and convenient solution for users to network their Ethernet devices 2 Switch Panel DN 651129 Side panel P1 and P2 are the number of connecting terminals P 1 and P 1 are respectively to the positive and negative poles to be connected Earthing screw used for earthing equipment DN 651129 ...

Page 3: ...n Internal storage and forwarding mechanism support a variety of protocols In line with industrial operating standards the average trouble free work in more than 300 000 hours Working power supply DC 12 52V to provide reverse protection Lightning Surge Protection Power 5000A 8 20μs 4 Specification 4 1 Standard IEEE802 310BASE TIEEE802 3i 10Base T IEEE802 3u 100Base TX FX IEEE802 3ab1000Base T IEEE...

Page 4: ...ling no fan Weight 0 9Kg Measurement 175 6 x 135 x 45 5 mm 4 7 Industrial standard FCC CFR47 Part 15 EN55022 CISPR22 Class A IEC61000 4 2 ESD 8kV contact 12kV air IEC61000 4 3 RS 10V m 80 1000MHz IEC61000 4 4 EFT Power Port 4kV Data Port 2kVIEC61000 4 5 Surge Power Port 2kV DM 4kV CM Data Port 2kVIEC61000 4 6 CS 3V 10kHz 150kHz 10V 150kHz 80MHz IEC61000 4 16 Common mode conduction 30V cont 300V 1s...

Page 5: ...pin definition is shown in the following figure RJ45 port supports automatic MDI MDI X operation you can use a straight line to connect to the PC or server connect to other switches or hubs In the through line MDI pins 1 2 3 4 5 6 7 8 correspond to the connection For the MDI X port of a switch or hub cross lines are used 1 3 2 6 3 1 6 2 4 7 5 8 7 4 8 5 10Base T 100Base T X pins are defined as foll...

Page 6: ...injury caused by improper use please follow the following precautions In order to avoid damage caused by falling of the equipment please put the equipment in a stable environment When supplying power to the equipment pay attention to confirm the range of power supply voltage as well as the positive and negative poles of the power supply so as not to damage the equipment by wrong operation In order...

Page 7: ...the guide rail and the switch are fixed on the guide rail vertically and stably 7 3 Grounding Fix the grounding wire to the grounding screw above the switch and ensure good reliable connection of the grounding system 7 4 Power Connection Insert the power cord into the specified position of the 6 core terminal and insert the terminal into the standard power supply inlet P 1 and P 1 input correspond...

Page 8: ...e the user may be required to take appropriate measures Hereby Assmann Electronic GmbH declares that the Declaration of Conformity is part of the shipping content If the Declaration of Conformity is missing you can request it by post under the below mentioned manufacturer address www assmann com Assmann Electronic GmbH Auf dem Schüffel 3 58513 Lüdenscheid Germany ...

Reviews: