Digitronic
CamCon Terminal
Automationsanlagen GmbH
DC51/T
5.1.1. LCD - contrast setting
To adjust the LCD display contrast, enter the main
menu of the CamCon Terminal. Press the
key to let
the display show the Digitronic Logo. Here (and only
here) you can adjust the contrast of the Liquid Crystal
Display with the keys
and
. Holding these keys
pressed in - or decreases the contrast continually.
Pressing the
ends the input, and the Terminal
automatically tries to establish contact with a CamCon
cam controller.
5.1.2. Menu "1 Start Terminal"
You choose this menu, when you want to make contact with a CamCon cam controller. After having
selected this menu, the display shows the request for the input of the unit number with which you want
to make contact. Here you can enter a number between 0
and 63. Entering the unit number of the Terminal is not a
valid input. In the picture to the left, this number is e.g. 60.
By pressing the
key, the input is confirmed and the
Terminal tries to make contact with a device with that unit
number.
Once a data connection is established the main menu of
the cam controller is displayed on the screen of the
Terminal. Now you can start with the programming of your
cam controller, as described in the corresponding handbooks. To break the connection between
Terminal and cam controller, leave any current submenu of the cam controller by pressing the
key.
Back in the main menu, press and hold down the
key for about 2 seconds, and return to the main
menu of the CamCon Terminal.
Note:
If you use the CamCon Terminal with several CamCon cam controllers on one RS485
BUS, you have to connect the devices and allocate the different unit numbers one by
one, as well as the communication mode (
"Ser.Mode"
). Any unit number may only be
assigned to
one device
, and the communication mode has to be set to
"Ser.Mode"
on all devices (see chapter 5.1.5. Menu "4 Terminal config. on page 10 and in the
corresponding handbooks of the CamCon cam controllers DC16,50,90 and DC115). At
the RS485 BUS, the only valid settings are "
Multiuser
" and "
CAM-BUS
". If a setting to
the
"Ser.Mode"
communication mode is not possible with any device, get a software
upgrade for it.
If contact is not made, the message "No contact with unit 0 !" is displayed after 5 seconds.
Press the
key once to return to the main menu. One cause for a connection failure could be an
invalid setting in the configuration (see above) or an error in the wiring of the serial interface (see page
6).