background image

Digitronic

CamCon Terminal

Automationsanlagen GmbH

DC51/T

5.1.5. Menu "4 Terminal config."

You select this menu, in order to configure the terminal.

Before  you  can  continue,  enter  your  user  key  with  the
access to the device configuration. If you did not assign a
user  key,  enter  the  keycode  "5693"  and  press  the  key

.

Afterwards the submenu  in  the  screen,  represented  right,
appears.

5.1.5.1. Sub menu "Terminal konfig."

You  select  this  menu,  if  you  want  to  adjust  the
communication  mode  and  the  CamCon  terminal  unit
number.  The communication mode becomes here by the
designation  "

Term  mode

"  and  the  unit  -  and/or  device

number by the designation "

Terminal no

." shortened.

For the selection of the communication mode by pressing
of the keys 

 and 

 the desired communication mode

is selected and taken over by the pressing of the key 

.

If the assumption took place, then now the input of the Terminals No. or device number is expected.
Also this is taken over with the key 

 and can vary between 0 to 63. The specification of the individual

terminal modes takes place in the next chapter

Press the 

 key once to return to the main menu.

5.1.5.2. The communication mode or terminal mode (Ser.Mode)

The  CamCon  Terminal  offers  five  different  communication  modes.  These  are  1.  =  "Cam-BUS",  2.  =
"Standard", 3. = "Multiuser" 4. = "S5-L1" and 5. = "3964R". If a specific mode is selected, make sure
that  every  device  with  which  you  want  to  communicate  supports  that  communication  mode.  Please
note  that  you  have  the  option  of  selecting  the  type  of  interface  you  want  with  your  offer:  DC51/T4  =
RS485  or  DC51/T2  =  RS232.  All  five  comunicationmodes  work  as  well  in  the  RS232  point  to  point
comunication as in the RS485 BUS comunication.

5.1.5.2.1. The "Cam-BUS" communication mode

Select  this  setting,  if  wish  to  be  able  to  program  and  display  one  or  more  CamCons  from  different
terminals. This is e.g. the case, if you want the Camcon Terminal DC51/T4, the daughter display CD10
and the PC to communicate with one or several devices via an RS485 BUS.

Attention:

With this setting, 

all

 CamCon devices and connected PCs with an RS485 interface have

to be equipped with a software version from December1996 or later.

Version: Jul. 04

Page: 10

  2 rue René Laennec 51500 Taissy France

 

Fax: 03 26 85 19 08,  Tel : 03 26 82 49 29

 

E-mail:[email protected]

Site web : www.hvssystem.com

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for CamCon DC51/T

Page 1: ...en Tel 49 7022 40590 0 Fax 10 Auf der Langwies 1 D 65510 Hünstetten Wallbach Tel 49 6126 9453 0 Fax 42 Internet http www digitronic com E Mail mail digitronic com 2 rue René Laennec 51500 Taissy France Fax 03 26 85 19 08 Tel 03 26 82 49 29 E mail hvssystem hvssystem com Site web www hvssystem com ...

Page 2: ...istics and damages which were caused deliberately or through negligence Protection The CamCon DC51 T and this instruction manual are protected by copyright All rights are reserved Neither the CamCon DC51 T nor this document may be copied as a whole or partially photocopied reproduced translated or transferred to electronic media of any kind or into machine readable format without prior written per...

Page 3: ...de 11 5 1 5 2 5 The 3964R communication mode 11 5 1 6 Menu 5 Terminal Language 11 5 1 6 1 submenu device group 11 5 1 6 2 Submenü Key code administration 12 6 Technical data 12 7 Key word table 13 1 Introduction The CamCon Terminal DC51T is a graphic programming unit for cam controllers of the CamCon family As a standard the CamCon Terminal is equipped with background ilumination and an RS485 inte...

Page 4: ...st be done in a cold state The connection cables e g for the measuring system or the serial interface must be wired with covers and the covers have to grounded on both ends Analog signals must also be wired with covers and the covers have to be grounded on one end 2 1 Dimensions front door can be locked cutout as per connection clip Fig Drawing to help with the installation of the CamCon Terminal ...

Page 5: ...n of the serial interface You can specify the type of the serial interface RS232 or RS485 with your order Depending on the type of serial interface the connections and the wiring change DC51 T4 RS485 DC51 T2 RS232 3 1 2 1 Pin allocation of the serial RS232 interface DSUB 9 pinboard RS232 Interface for PC attachment max 15m cable length Pin 1 4 Do not connect Pin 2 TXD Pin 3 RXD Pin 5 GND Pin 6 9 N...

Page 6: ...t number 60 with bridged close down resistors CamCon DC16 Unit number 1 without bridged close down resistors without bridged close down resistors Unit number 2 CamCon DC16 with bridged close down resistors interface converter PC Note The pins 1 and 2 as well as the pins 3 and 4 have to be bridged in the attachment plug of the first and last device in a networked chain at the RS485 Interface to clo...

Page 7: ...well as the unit number is displayed in the top line of the main menu Attention The unit or device numbers may only be allocated once on an CamCon RS485 BUS Main menu CamCon Terminal The main menu is the starting point of the operation You can select the desired menu by pressing the corresponding numeric key or by moving the black beam on the desired menu point with the keys and and confirming you...

Page 8: ...er as described in the corresponding handbooks To break the connection between Terminal and cam controller leave any current submenu of the cam controller by pressing the key Back in the main menu press and hold down the key for about 2 seconds and return to the main menu of the CamCon Terminal Note If you use the CamCon Terminal with several CamCon cam controllers on one RS485 BUS you have to con...

Page 9: ...ext program 1 in device 4 is selected After completion of the program selection a message appears If an error message appears then program selection was not possible and is again to be implemented Possible sources of error are wrong device numbers or errors in the wiring of the serial interface The program selection can be left at any time by operation of the key 5 1 4 Menu 3 Unit list Select this...

Page 10: ... next chapter Press the key once to return to the main menu 5 1 5 2 The communication mode or terminal mode Ser Mode The CamCon Terminal offers five different communication modes These are 1 Cam BUS 2 Standard 3 Multiuser 4 S5 L1 and 5 3964R If a specific mode is selected make sure that every device with which you want to communicate supports that communication mode Please note that you have the o...

Page 11: ...he CamCon Terminal and the CamCon cam switch can be connected 5 1 6 Menu 5 Terminal Language If you selected the menu point Language in the main menu you enter the menu for the selection of the terminal language Here you can select the desired language with the keys and and cornfirm it with the key Note The language settings of the CamCon Terminal and the CamCon cam controllers operate independent...

Page 12: ...play 128 x 64 pixels with background illumination Interface RS485 up to max 1000m or RS232 up to max 15m Supply voltage 24V DC 20 Current absorbtion about 300mA Connections for Interface via D SUB 9 Voltage supply via plug block pins Dimensions see chapter 2 1 Dimensions on page 4 Operating temperature 0 C 55 C Switchboard normencasement DIN 43700 144 x 144 x 55mm WxHxD Weight about 700g Version J...

Page 13: ...ministration 12 LCD contrast setting 8 Main menu 7 Menu 1 Start Terminal 8 Menu 2 Programme selection 9 Menu 3 Unit list 9 Menu 4 Terminal config 10 Menu 5 Terminal Language 11 millenium 2 Operation of the CamCon Terminal 7 PDF File 2 Pin allocation 5 Pin allocation of the voltage supply 5 programm selection 11 Serial interface 5 Serial RS232 interface 5 Serial RS485 interface 6 Table of contents ...

Reviews: