DIGITEN WTC100 User Manual Download Page 6

receiver.

2, Press and hold

button, the LED flashes 5 times, then flash 2

times quickly before release the button. All remotes will be unpaired.

If you repair the remote, please repeat the step 1.

Note

A remote can control multiple receivers.

Change the temperature unit

Press the

button for 3 seconds to switch the temperature unit.

Cooling mode

Set the temperature value RUN>STOP, the controller is in cooling

mode, and the LCD displays the COOLING symbol

1.1 When the CURRENT temperature value is higher than the RUN

value, the cooling operation starts, the relay outputs, the LCD displays

, and the green light on the receiver is on. When the CURRENT

value drop to the STOP value, the cooling operation stops, and the

LCD displays

. The green light on the receiver is off.

1.2 When the CURRENT temperature value is less than the RUN

value, the cooling operation stops, the relay has no output, the LCD

displays

, the green light on the receiver is off. When the

CURRENT value rises to the RUN value, the cooling operation starts,

the LCD displays

, the green light on the receiver is on.

Summary of Contents for WTC100

Page 1: ...USER MANUAL Wireless Thermostat...

Page 2: ...set temperature run temperature and stop temperature Automatic cooling or heating Manually turn on off function C F can be switched High low temperature alarm Memorize all the setting value Low batter...

Page 3: ...Receiver Remote controller LCD display...

Page 4: ...0V AC Load capacity 100 240VAC 13A 1500W 110VAC 2500W 220VAC Remote batteries requirement 2PCS 1 5V AAA standby for 6 months Transmission distance 100m open space Measuring temperature range 10 0 C 80...

Page 5: ...AA size batteries are needed for the remote Make sure they are put in right direction 2 When the low battery warning appears please change batteries Pair remove with the remote In generally we have al...

Page 6: ...e COOLING symbol 1 1 When the CURRENT temperature value is higher than the RUN value the cooling operation starts the relay outputs the LCD displays and the green light on the receiver is on When the...

Page 7: ...is greater than the STOP value the heating operation stops the LCD displays the green light on the receiver is off when the CURRENT temperature drop to the RUN value the heating work starts the LCD d...

Page 8: ...the SET button until the corresponding value flashes At the same time the is displayed on the LCD Press the or button to change the number Short press SET button to set next valve or long press the SE...

Page 9: ...SET button to set High and Low value 4 Long press SET to save and exit Restore factory settings In the case of POWER OFF press and hold the SET button to power on at the same time After a long beep a...

Page 10: ...e display Short press the M key to turn on off the device Long press the M key to exit the manual control function Note Short press on the receiver to turn on off loading until it receive command from...

Page 11: ...probe open circuit prompt LCD current value shows Err 4 2 the measured temperature exceeds the measurement range the current value shows HH high temperature LL low temperature WARRANTY The DIGITEN pr...

Reviews: