DIGITEN DHTC-1011 Quick Start Manual Download Page 8

function.
Correct temperature = temperature before calib calibration 
value (CA), the calibration value can be positive, negative, or 0.

Troubleshooting

The load doesn’t work

1. The green indicator light is on, but the load does not work.
Please use a multimeter to measure the socket of the controller. If the 
voltage is 100-240VAC, please check your load device. Otherwise, 
please contact the DIGITEN Customer Service.
2. The green indicator light is on, but the load does not work.
When energized, the PV is exactly within the RV and SV, which meets 
your requirements, so the load device doesn't need to be turned on at 
this time.

Err Alarm

When the temperature sensor is short-circuited or disconnected, pull 
out the sending plug of sensor from the controller, and then press the 

plug firmly into the hole of the controller after cleaning the plug.

WARRANTY

The DIGITEN products are guaranteed to the original owner for one 
year against defects in workmanship and materials. Please contact us:

[email protected] 
www.digit-en.com/support

COPYRIGHT 2020 DIGITEN CO., LTD ALLRIGHTS 

RESERVED

Summary of Contents for DHTC-1011

Page 1: ...Temperature and Humidity Controller Model DHTC 1011 www digit en com service digit en com...

Page 2: ...100 240VAC Input Power Cable Length 120 cm 4ft Output Power Cable Length 30cm 6 5 Feature Large LCD screen Dual relay output be able to control heating cooling equipment and humidification dehumidific...

Page 3: ...on OFF Loading working status is off HI High temperature humidity alarm value LO Low temperature humidity alarm value Setting Instruction View the setting value Short press the SET button and you can...

Page 4: ...ns that the cooling equipment is in the delayed start protection state When PV SV the green light will go out and the cooling equipment will stop working 1 Long press the SET button until the appears...

Page 5: ...ppears and the flashes 2 Short press the UP or DOWN button and there will be a flashing then press the SET button to select the Humidity 3 Press UP or DOWN to adjust the RUN value you required 4 Short...

Page 6: ...l the appears 2 Short press the SET button to select the temperature 3 Press the and button to set the RV to 76 F 4 Short press the SET button to the SV value page Long press SET button for 3s Run tem...

Page 7: ...rature humidity alarm value 4 0 1 2 0 C 4 0 2 4 8 F 0 RH 99 RH 40 C 5 RH DP Time of compressor Delay Starting 0 10minutes 0minutes CA Temperature Humidity Calibration 1 5 1 5 C 1 5 1 5 F 10 RH 10 RH 0...

Page 8: ...ht is on but the load does not work When energized the PV is exactly within the RV and SV which meets your requirements so the load device doesn t need to be turned on at this time Err Alarm When the...

Reviews: