DIGITEN DHTC-1011 Quick Start Manual Download Page 2

Temperature

Humidity

Control Range

-40~120

°

C, -40~248

°

F

1-100%RH

Temperature 

Resolution

0.1

°

C, 0.1

°

F

0.1%RH

Temperature Accuracy

±0.3

°

C, ±0.3

°

F

±2%RH

Control Mode

Heating and Cooling

Humidification and 

Dehumidification

Input Power

100~240VAC, 50/60Hz

Temperature Control Output

Max.10A, 100-240VAC

Max.7A, 100-240VAC

Buzzer Alarm

High and Low Temperature 

Alarm

High and Low humidity Alarm

Sensor Type

Digital sensor

Sensor Length

2m, 6ft

2m, 6ft

Relay Contact Capacity

Heating

10A, 100-240VAC

Humidification

7A,100-

240VAC

Cooling

10A, 100-240VAC

Dehumidification

7A,100-

240VAC

Input Power Cable Length

120 cm/4ft

Output Power Cable Length

30cm/6.5”

Feature

• Large LCD screen;
• Dual relay output, be able to control heating / cooling equipment and 

humidification /  dehumidification device at the same time;  

• Support reading with Centigrade or Fahrenheit unit; 
• Maximum temperature output load: 1100W@110V, 2200W@220V;
• Easy to use and program, plug and play device;
• With temperature and humidity calibration function;
• Compressor delay protection for refrigeration control;
• High and low value alarms are available;
• Over-temperature and sensor fault alarm;

• Heating/cooling return difference could be set separately to protect 

temperature controller from violent change;

• The temperature or humidity function can be used separately.

Specification

Summary of Contents for DHTC-1011

Page 1: ...Temperature and Humidity Controller Model DHTC 1011 www digit en com service digit en com...

Page 2: ...100 240VAC Input Power Cable Length 120 cm 4ft Output Power Cable Length 30cm 6 5 Feature Large LCD screen Dual relay output be able to control heating cooling equipment and humidification dehumidific...

Page 3: ...on OFF Loading working status is off HI High temperature humidity alarm value LO Low temperature humidity alarm value Setting Instruction View the setting value Short press the SET button and you can...

Page 4: ...ns that the cooling equipment is in the delayed start protection state When PV SV the green light will go out and the cooling equipment will stop working 1 Long press the SET button until the appears...

Page 5: ...ppears and the flashes 2 Short press the UP or DOWN button and there will be a flashing then press the SET button to select the Humidity 3 Press UP or DOWN to adjust the RUN value you required 4 Short...

Page 6: ...l the appears 2 Short press the SET button to select the temperature 3 Press the and button to set the RV to 76 F 4 Short press the SET button to the SV value page Long press SET button for 3s Run tem...

Page 7: ...rature humidity alarm value 4 0 1 2 0 C 4 0 2 4 8 F 0 RH 99 RH 40 C 5 RH DP Time of compressor Delay Starting 0 10minutes 0minutes CA Temperature Humidity Calibration 1 5 1 5 C 1 5 1 5 F 10 RH 10 RH 0...

Page 8: ...ht is on but the load does not work When energized the PV is exactly within the RV and SV which meets your requirements so the load device doesn t need to be turned on at this time Err Alarm When the...

Reviews: