30
2.1 Technical data
Voltage supply
24 V DC (18 ... 30 V), max. current consumption for MP9000: 2.4 A
Power consumption
Max. 50 W
Connector
Input voltage connector type Phönix COMBICON,
MSTB 2.5/ 3-STF-5.08
Safety
VDE 0805 (EN 60950), VDE 0870, UL
Emissions
CE-Sign, EN 50082 (IEC 1000-2,-3,-4), EN 50081 (EN 55022)
Shock
10 g / 11 ms (IEC 68)
Temperature
5 to 50 °C (in operation)
-10 to 60 °C (storage)
Air humidity
Min. 10 % to max. 90 % (not condensing)
Enclosure
IP20;
front of the EL series IP65 if mounted professionally
Class of protection
Class of protection 1
Max. dimensions
See chapter 5 Dimensions and mounting
space
Device type
Minimum weight of
basic device
MP600 2.4
kg
MP1000
4.2 kg
MP1000s 4.2
kg
MP1050
4.6 kg
MP1050s 4.6
kg
MP2000
5.4 kg
MP2050 5.6
kg
MP5000
6.2 kg
MP5020 6.4
kg
MP5050
6.4 kg
MP5070 7.2
kg
MP9000
10.2 kg
The monitor panel may not be used in potentially explosive atmosphere.
If the device is mounted in a separate housing, it is to be observed that the maximum ambient
temperature with a peak of 45 °C (<35 °C average temperature) is not exceeded. If required,
appropriate measures for passive and active cooling are to be implemented.
All information provided without warranty:
The company Lenze Digitec Controls GmbH reserves the right for changes,
in particular with regard to the values, dimensions and weights specified,
unless they are not noted differently.