Routing Commands
RS232 Commands
RS232 Settings:
•
57600 baud
•
8 Data Bits
•
1 Stop Bit
• Parity = none
<CR> = Carriage return.
<LF> = Line feed
Take Command DISPLAY AUTO prm[CR/LF]as an example:
1. [DISPLAY AUTO] denotes command key words, case in-sensitive.
2. [prm] denotes parameters, case in-sensitive, incorrect parameters number will not be recognized.
3. [CR/LF] is needed, all commands end up with [CR/LF].
Description
Command Example
Response
Switch Input for Output
Ex: Switch Input port 1 to output port 2
Set 01 02[CR/LF]
01 02[CR/LF]
Switch all outputs to the same input
Ex: Switch all outputs to input port 2
SET 02 all[CR/LF] 02 01[CR/LF]
02 02[CR/LF]
02 03[CR/LF]
02 04[CR/LF]
Get a specific output port routing information
Ex: Output port 1 is routed to input port 2
GET 01[CR/LF]
02 01[CR/LF]
Get routing status for all inputs and outputs
Ex: All outputs are routed to input port 2
GET all [CR/LF]
02 01[CR/LF]
02 02[CR/LF]
02 03[CR/LF]