with right key and adjust ring volume with down key. Volume can only be adjusted from
high to low and ring tones can only be chosen from 1
st
to 25
th
. After monitor is power off,
ring setting change can’t be saved.
(4). Unlock duration setting: in bright screen status, long press surveillance key( ) 3
seconds to enter function settings. Continuously touch this button 3 times to enter unlock
setting. Adjust with up/down key; optional duration is 1-6 seconds with default 1 second.
(5). PIR on/off: in bright screen status, long press surveillance key( ) 3 seconds to enter
function settings. Continuously click this key 4 times for PIR setting. Select on/off with
up/down key.
(
6). Mute mode setting: in bright screen status, long press intercom key( ) 3 seconds,
green music symbol( ) on screen becomes crossed red sign( ); this is mute mode. In
this mode, for incoming calls, monitor works normally but doesn't ring. Long press intercom
button 3 seconds to cancel mute mode.
(7). Indoor unit intercom volume adjustment: in intercom status, press left(low) /right(high)
to adjust monitor’s intercom volume, with 0-7th grade scope and default 5th grade.
(8). Chroma adjustment: in intercom or surveillance mode, press up/down button to adjust
screen color; grade option ranges from 0 to 9. Image will be black/white if grade is 0.
Operation Introduction
(1). Outdoor unit booting
Install battery in outdoor unit, put it well into rain cover, then camera can work with monitor.
Please fix battery correctly.
(2). Indoor unit power on/off
After battery is installed, long press power switch for 3 seconds to boot monitor. If no
operation after 30 seconds, monitor will get into standby status. With bright screen, long
press power switch for 3 seconds to shut monitor down; press power switch or intercom
button( ) to enter standby status; then click any key to brighten screen.
(3) Monitor intercom and unlock
After visitor presses Call key, outdoor unit's indicator blinks blue and beeps; monitor rings
immediately and displays camera's image. Click monitor's intercom key( ) to talk to visitor
and press power switch to remotely control outdoor unit for door release. After intercom is
over, press intercom key again to ring off and monitor will be in standby status. If monitor
doesn't answer outdoor unit's call in 5 seconds, a photo will be captured and saved by
monitor. If call is not answered in 30 seconds, both monitor and camera will enter standby
status; monitor has missed call record. During intercom, if no key is pressed in 90 seconds,
both devices come into standby