background image

ADD Common identificators

 Common identificators is a special key the most commonly used in networked versions to open all doors in

sistem . Sixteen key of such type could be entered to door phone memory.

For recording Common identificator to memory choose 

[1.tAG]

 > 

[3.C.Add] 

from menu and attach a new 

key to reader.

[1.tAG]

 > 

 > 

[3.C.Add]

 > 

 > 

[C- (x)]

 > (add new keys one by one)

[C- (x)]

  shows recorded identificator’s rank number in door phone memory.”C” means, that this key is

Common identificator.

Auto Add function

Auto add function enables to easily add user tags for themselves. If this function is enabled, when tag is

placed, it immediately is written to memory and doors opens. ID number will be shown on the screen, when new
tag is placed. Next time the tag is placed, tag ID will be shown on the screen and doors will open. When all tags
was   read,   auto   add   function   must   be   disabled.  Auto   add   function   is   very   useful   in   situation   when   DD-5100
configuration was lost or doorphone was damaged – users can add their keys without installer help (after repair
work).

To on auto add function do the following:

[1.tAG]

 > 

 > 

[3.AutoAdd]

 > 

 > 

[1.on]

 > 

 > 

donE

.

To off auto add function do the following:

[1.tAG]

 > 

 > 

[3.AutoAdd]

 > 

 > 

[1.oFF]

 > 

 > 

donE

.

Delete identificator

Delete submenu structure is shown in fig. 15.

Delete identificator, related to sequence number

Identificator’s sequence  number is set  in  door phone  memory  automatically after  adding new  one.  This

number is shown on a display, each time when door is unlocked using an appropriate identificator. This number
helps to delete a wished key (lost, defected) from door phone memory. See an example of deleting identificator with
a rank number n=23

[1.tAG]

 > 

 > 

[5.dEL]

 > 

 > 

[1.onE]

 >   

 > 

[Id- ]

 > (enter no.=23) > 

 > 

[donE]

 –

identificator deleted

Delete identificator, related to user ID

One ID could be related to several identificators. This function helps to delete it together at once. See an

example of deleting identificators , related to ID=34

[1.tAG]

 > 

 > 

[5.dEL]

 > 

 > 

[2.GrouP]

 >  

 > 

[Id- ]

 > (enter ID=34) > 

 > 

[n. 34]

 >

[donE]

 – all identificators, related to a subscriber from a flat No. 34 (ID=34)

Delete all identificators from the memory

For   deleting   all   identificators   (including   Service   identificators)   from   the   memory   perform   the   operation,

23

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

Fig. 14: AutoAdd submenu structure

[1.on]

 – turn auto add function on

[2.oFF]

 - turn auto add function off

[3.AutoAdd]

[1.tAG]

Fig. 15: Delete submenu structure

[1.onE]

 - delete one user tag

[2.GrouP]

 - delete all tags of selected user 

[3.S.OnE]

 - delete system tag by its number

[5.ALL]

 - delete all tags

[5.dEL]

[1.tAG]

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

[4.C.OnE]

 - delete Common tag by its number

Summary of Contents for DD-5100

Page 1: ...DIGITALas JSC Ukmergės 234A Vilnius LT 07160 Tel 370 5 2336619 info digitalas lt www digitalas eu ...

Page 2: ...Digital Door phone DD 5100 ...

Page 3: ...lete system identificator related to sequence number 22 4 3 2 Actions with codes 22 Set change users door unlock code 23 Change Service PIN SPIN code 23 4 3 3 System settings 23 Setting of unlock delay time 23 Selection of a lock type 23 Access control settings 24 Door unlock timer in error case 24 4 3 4 Volume control 24 Indoor volume control 25 Outdoor volume control 25 System signals sound cont...

Page 4: ...0 5 2 3 NET3 31 5 3 Network configuration 31 5 3 1 Net configuration examples 31 5 4 Error codes 31 Chapter 6 Error its identification and troubleshooting 32 User Manual 33 1 How to use a door phone 33 2 Entering from outside 33 3 Internal door unlock 33 4 Changing of user s PIN code 33 5 Programming of new identificators 34 2 ...

Page 5: ... 3 minutes 1 1 General features of the DD5100 Digital Door phone Possibility to connect up to 255 users Duplex audio connection Two Wire connection line TM Tags reader RFID Tags reader Internal memory of 1376 Tags Individual door unlock code Possibility to turn off door unlock codes Possibility to add six Service Tags The doors could be opened by entering the door unlock code using TM or RFID Tags...

Page 6: ...100 1 2 Dimensions Fig 1 Dimensions of DD 5100 door phone Fig 2 Dimensions of door phone rain shield DR 1 4 1 2 3 4 5 6 7 8 9 ENTER 0 CANCEL 120 110 110 30 33 30 31 30 33 261 120 251 110 263 122 30 33 30 33 ...

Page 7: ...Fig 3 Dimensions of Name frame NF 1 5 120 110 110 30 32 30 31 30 32 261 120 251 110 ...

Page 8: ...nic lock DD 5100 call module could manage two types of electric locks electric opener and electromagnetic lock managed by a permanent 12V flow A nominal flow for electric lock must not exceed 0 8A Lock type and locking delay time are set by the program Door unlock button Door unlock button used for unlocking the door when leaving the object In this case any standard button with normally opened con...

Page 9: ...switch LINE positive line contact line connects all handsets to doorphone LC negative contact of electric lock or electromagnet LC positive contact of electric lock or electromagnet By default doorphone drives electromagnet To drive electric lock appropriate settings should be done in doorphone settings menu please refer to menu section 3 2 on page 18 Additional contacts used to implement specific...

Page 10: ...ne circuit as it is intended for commutation GND ground contact CPW video camera power supply contact 12 V voltage appears when calling and during conversation session In order to ensure quality of image use a coaxial wire for transfer of video signal 3 3 Door phone connection to the network A network connection is needed in case a room residential house or office has several entrances In this cas...

Page 11: ...nfigured as H type DD 5100 configured as L type Electric lock electromagnet Regulated power supply 12VDC 1 5A Door unlock switch GND 12V Door unlock switch Regulated power supply 12VDC 1 5A GND 12V Electric lock electromagnet Communication line Handsets Monitors Video splitter VD 1x5 VIN VO5 VO1 VO2 VO3 VO4 12V GND Power supply 12VDC 0 3A Monitor power supply LG C L CG V GND Wires soldered to sold...

Page 12: ...V1 commutators as shown in fig 10 In this setup any network configuration for all DD 5100 s should be turned off in settings menu In wiring diagram in fig 10 is depicted network implementation for object which includes gates of the closed yard and three entrances at the stairways In case more than two H type DD 5100 s needs to be connected to network H type DD 5100 s should be connected through ne...

Page 13: ...nication line Video splitter VD 1x5 VIN VO5 VO1 VO2 VO3 VO4 12V GND Handsets Monitors Monitor power supply LG C L CG V GND Electric lock electromagnet Electric lock electromagnet To other monitors L IN LINE LGND LC LC GND P12V UNL GND ILMN BUS D1 D0 CPW GND CAM DD 5100 configured as 1 st L type doorphone Door unlock switch Regulated Power supply 12VDC 1 5A GND 12V Communication line Video splitter...

Page 14: ...12V GND Handsets Monitors Monitor power supply LG C L CG V GND Electric lock electromagnet To other monitors Power supply 12VDC 0 3A LED1 BUS L1 GND GND 12V L2 GND L3 GND OUT GND DD S2 1 L IN LINE LGND LC LC GND P12V UNL GND ILMN BUS DD 5100 configured as 1 st H type doorphone Door unlock switch Regulated power supply 12VDC 1 5A GND 12V Electric lock electromagnet BUS common Line of 2 nd H type DD...

Page 15: ...VD 1x5 VIN VO5 Power Supply 12VDC 1 5A Power Supply 12VDC 1 5A Power Supply 12VDC 0 5A VO1 VO2 VO3 VO4 12V GND Power Supply 12VDC 0 3A Monitor Power Supply V GND L IN LINE LGND LC LC GND P12V UNL GND ILMN BUS D1 D0 CPW GND CAM 1 st DD 5100 with network Configuration disabled L IN LINE LGND LC LC GND P12V UNL GND ILMN BUS D1 D0 CPW GND CAM 2 nd DD 5100 with network Configuration disabled Door Unloc...

Page 16: ...DC 0 5A Pover Supply 12VDC 0 5A LED1 BUS L1 GND GND 12V L2 GND L3 GND LOUT GND DDSV1 1 C1 C2 C3 COUT LED1 BUS L1 GND GND 12V L2 GND L3 GND LOUT GND DDSV1 2 C1 C2 C3 COUT LED1 L1 GND L2 GND L3 GND LOUT GND C1 C2 C3 COUT BUS GND 12V Pover Supply 12VDC 0 5A Audio Video Line 1 DDSV1 3 Vaizdo daliklis VD 1x5 VIN VO5 VO1 VO2 VO3 VO4 12V GND DD 5100 4 Audio Video Line 3 Pover Supply 12VDC 0 3A ...

Page 17: ...mming mode activation enter 1002 and enter SPIN code If you enter a wrong SPIN code try one more time If you enter wrong SPIN code 3 times a programming mode will be blocked for 5 minutes Programming mode could be activated using Service Tag For programming mode activation enter 1002 and attach Service Tag to the reader After activation of programming mode browse the MENU by using buttons Button u...

Page 18: ...U Pin 2 S Pin 3 C Pin 4 rESEt ALL 3 Settings 1 Lc Delay 2 Lc Type 1 Nc 2 No 3 Acc Type 1 Code 1 Dis 2 En 2 T Tag 1 Dis 2 En 3 R Tag 1 Dis 2 En 4 Err Unl 1 Set 2 off 5 CS no 6 UnL beep 1 on 2 oFF Chip set 1 on 2 oFF 4 Vol 1 User 2 Guest 3 Syst 5 User 1 Disable 1 One 2 Group UcLc 2 Enable 1 One 2 Group UcLc 6 Addressing 1 Regular 2 Shifted 3 Hotel 1 Add Int 2 Start ...

Page 19: ...On Function is ON Off Function is OFF When this function is ON all new User Tags will unlock the door and will be saved to the memory 4 Del Delete Tag 1 One Delete one User Tag 1 Enter U Tag number 1 1376 and press Enter 2 Or add U Tag to the reader visual and audio notifications done pyyp U Tag is deleted Err pyp pyp Incorrect U Tag number n 0 or n 1376 2 Group Delete all User Tags related to one...

Page 20: ...ed Err pyp pyp Wrong time value 0 or 99 2 Lc Type Lock Type 1 nc Normal closed circuit electromagnet 2 no Normal open circuit electric bolt visual and audio notifications done pyyp Setting is saved 3 Acc Type Type of Access Control 1 Code Access to unlock door by using User PIN code 1 dis Access is disabled 2 en Access is enabled visual and audio notifications done pyyp Setting is saved 2 t tag Ac...

Page 21: ...device speaker volume 1 9 Factory value 5 visual and audio notifications done pyyp Setting is saved 2 Guest Guest outdoor station device speaker volume 1 9 Factory value 5 visual and audio notifications done pyyp Setting is saved 3 Syst System signals volume 1 9 Factory value 5 visual and audio notifications done pyyp Setting is saved 5 User User administration 1 Disable Disable User ID 1 One Disa...

Page 22: ...e context of this menu depends on configuration state Default configuration or when network or all settings has been reset 7 Net Network settings 1 Set Enable Net configuration 1 nt1 First type network configuration Please refer to Chapter 3 for more info 1 H Set H type doorphone ID setting min HID 1 max HID 255 donE pyyp HID address successfully saved Err pyp pyp wrong ID typed 0 HID 256 2 L Set ...

Page 23: ...ee table After reset system will restart 2 All Reset settings to the factory values see table and delete memory all Tags After reset system will restart Table 2 Programming settings functions and factory values Menu Setting function Description Factory value 1 Tag 1 3 AutoAdd Auto add User Tags 2 off 2 Code 2 1 U pin User PIN codes No codes assigned 2 2 S pin System PIN code No SPIN assigned 3 Set...

Page 24: ... from the memory Add Service identificators Service identificator is an auxiliary measure assisting to provide door phone maintenance six keys of such type could be entered to door phone memory Service identificator could be used for door unlock equally to traditional keys However this key activates programming mode without SPIN code For recording Service identificator to memory choose 1 tAG 1 S A...

Page 25: ...tor Delete submenu structure is shown in fig 15 Delete identificator related to sequence number Identificator s sequence number is set in door phone memory automatically after adding new one This number is shown on a display each time when door is unlocked using an appropriate identificator This number helps to delete a wished key lost defected from door phone memory See an example of deleting ide...

Page 26: ...can enter a new or change an old user s door unlock code Administrator s rights allow to change the mentioned code even without a previous one Delivery of a new code and change or an old one are performed according to similar procedure enter an appropriate subscriber s ID and enter a new code See an example of changing door unlock code for a flat No 56 2 CodE 1 U Pin Id enter ID 56 _ _ _ _ set new...

Page 27: ...door unlock could be forbidden totally upon a necessity Doors could be opened only by an internal unlock button or during conversation with a guest using audio receiver You could set one entrance control type or combine several ones In order to ensure safety residents often want to refuse using codes that could be learned by friends of residents or the third parties In this case set an access cont...

Page 28: ... changed from 1 to 15 The example shows how to set the maximum number of calls 3 SEttinGS 5 CS no no input value no 15 donE Unlock Signal in handset ON OFF Opening the door using the key or the code intercom intercom handset to a call informing about the fact that someone is coming to the apartment This item allows you to enable or disable this feature Unlocking the handset off the signal structur...

Page 29: ...le signals sounds of keyboard button pressing door unlock signal system informational signals and others except volume of conversation This function is necessary in case residents of the first floor are annoyed by too loud peeping of door phone system You could lower a door phone sound as preferred without changing conversational volume Loudness is changed as follows 4 voL 3 SYSt 06 change volume ...

Page 30: ...o enable user according ID is as easy as to disable After enabling a user all previous settings related to user s ID remain e g Door unlock code 5 USEr 2 EnAbLE 1 onE id enter ID e g ID 12 donE ID 12 enabled Enable a group of users ID A group of users ID is connected in the same way Enter the first and the last address as presented by an example 5 USEr 2 EnAbLE 2 GrouP F Id enter first address e g...

Page 31: ...otel addressing is a type when all 255 physical ID addresses are placed by a rank order from 1 to 255 while logic addresses will be scrolled upon number of floors and number of flats within a floor In order to configure hotel addressing for an appropriate house choose this type of addressing start a new addressing configuration and set intervals for logic addresses See fig 28 for hotel addressing ...

Page 32: ...ariants a main menu default configuration network disabled For this configuration network settings menu structure is shown in fig 29 To enable network configuration chose 1 SEt select on of NET types shown in fig 30 select either H master or L slave configuration and enter ID For more info about network configuration please refer to 5 3 Network configuration To enable NET1 network configuration an...

Page 33: ... ID 7 nEt 1 Edit H id enter ID let say 1 for first H type doorphone in network donE Network settings reset is done exactly the same way as in a variant main default menu 7 nEt 2 rSt nEt rSt n 0 donE After reset a variant main default network settings menu is active 4 3 8 Reset to factory settings DD 5100 has two reset options reset only DD 5100 settings and complete reset including deleting of all...

Page 34: ... SEttinGS 1 Lc dELAY Unlock delay time 1 100 sec 5 sec 2 Lc tYPE Lock type electromagnetic lock electric bolt NC electromagnetic lock 3 Acc tYPE Access control type code TM key RFID identificator 4 CS no Number of call signals 5 4 voL 1 Indoor Indoor volume level 1 10 6 2 outdoor Outdoor volume level 1 10 6 3 Sound System signals sound level 1 10 6 6 AddrESSinG Type of addressing regular shifted h...

Page 35: ...l Slave doorphone To this doorphone should be connected handsets line In this doorphone are saved main settings user keys and codes H High Level Master doorphone This doorphone interacts with L doorphone and through it calls to L doorphone connected handset H doorphone also asks L doorphone for programmed keys and codes to decide whether to open the H doorphone controlled doors To check selected d...

Page 36: ...ed apartment and press Enter To enter Your code first enter ID of L type doorphone connected to Your apartment then press star enter apartment address then again star and then enter Your code press Enter to proceed Codes are stored in L type doorphones so prior use they must be there To open doors using Your key You should do the following enter ID of L type doorphone connected to your apartment t...

Page 37: ...ly indicates the main errors Graphical codes and descriptions of errors fixed by a door phone are presented in table 5 In case of Er2 Er5 errors doors have been unlocked every 5 minutes automatically In case of Er 1 error calls to audio handsets fail but doors could be unlocked by door unlock code or using electronic identificators Table 5 Error indication and description Error code Possible reaso...

Page 38: ...DD 5100 Er 4 Er 5 restart the system switch off the door phone power supply and switch it on again In case error mark appears demount module and present it to service workshops 36 ...

Page 39: ...dentificator and a note OPEN appear on a display shortly with a sound signal In case an identificator is related to a flat a sound signal informing on door unlock using an electronic key will be sent to an handset Entering a door unlock code A door unlock code consists from a flat number ID a keyboard symbol and an individual 4 digits code XXXX ID XXXX For 4 digits code programming see Set change ...

Page 40: ...ach second 3 Four dashes will be shown on a display Enter PIN code 4 A new key list number will be shown on a display Attach a new identificator to the reader It will be programmed In case of attaching an old key the system peeps two times without re programming New keys should be programmed one by one separately In order to program several keys repeat the procedure several times Should a mistake ...

Reviews: