background image

 
AMBE-2000/2020™ Vocoder Interoperability at 2350 bps 
June 2004 

Page 

of 

2  

June 2004 

 

 
 
Compatible Mode Procedure Step 2. 
 
The next packet should be identical to the packet described in Table 3. 
 

Special Control Packet

 

Word # 

Value 

Description 

0 0x13ec Header 

0x0700 

Special Control packet 

0x0834 

Special control data 

0x0005 

Special control data 

0x11bf 

Special control data 

0x0005 

Special control data 

0x0000 

Must be 0x0000 

0x0000 

Must be 0x0000 

0x0000 

Must be 0x0000 

0x0000 

Must be 0x0000 

10 

0x0000 

Must be 0x0000 

11 

0x0000 

Must be 0x0000 

12-23 

 

Channel Data for AMBE® voice decoder 

Table 3.

 

 
 
Compatible Mode Procedure Step 3. 
 
After the packets detailed in Table 2 and Table 3 are sent into the AMBE-2000/2020™ 
Vocoder Chip the RIS bits in Control Word 2 must be set to 0x3 for each subsequent packet.  
If the rate is changed or the device is reset, the above procedure (steps 1, 2 and 3) must be 
repeated. 
 
 

Control Word 2 – (16-bits) 

Bit 15

 

14

 

13

 

12

 

11

 

10

 

9

 

8

 

7

 

6

 

5

 

4

 

3

 

2

 

1

 

Decoder Output Volume Control

 

Unused

0

 

Unused

0

 

VAD

 

Unused 

0

 

SL

 

EC

 

RIS 

Table 4.

 