background image

Arming and Disarming 

Graphic Touchscreen Keypad User’s Guide 

15

3.     Press 

ARM

 to display 

ALL? NO  YES

Enter your user code if required.

4.   Select 

NO

 to arm only selected 

areas. Go to step 5. Select 

YES

 to 

arm all areas authorized for your 

user code.

5.   If 

NO

 is selected in step 4, 

the display begins to list 

each area to which you have access followed by 

NO  YES

Example: 

OFFICE  NO YES

.

5a. Select 

YES

 for each area 

you want to arm.

5b. Select 

NO

 for each area 

you do NOT want to arm.

Note:

  

You may also press the area 

numbers you want to arm 

while ALL?  NO YES displays. 

This changes the display to 

AREAS:. The numbers you select  

appear in the display. For example: AREAS:  2  4. Press CMD 

when done.

6.  

The system displays any faulted 

and bypassed zones.

7.  At this point you can 

force arm

 

or 

bypass

 any faulted  burglary 

zones. A zone that is force armed 

is restored into the system if it 

later returns to normal. A zone 

that is bypassed remains bypassed until the system is disarmed. 

See steps 7a through 7d.

7a. If a problem exists on any 

zones, the zone name and 

problem are shown followed 

by: 

OKAY   BYPASS   STOP

.

7b. Select 

OKAY

 to force arm 

the zone(s) before arming.

7c. Select 

BYPASS

 to bypass the 

zone(s) before arming.

7d. Select 

STOP

 to stop the 

system from arming. 

 

Correct the zone problem(s) 

and return to step 1.

Note

 

24-hour zones cannot be 

bypassed.

8.   The  screen displays 

SYSTEM ON

 if 

at least one area in the system is 

armed, and 

ALL SYSTEM ON

 if all 

areas in the system are armed.

9.   The 

screen then displays the 

exit time in seconds and counts 

down the remaining time: 

ExIT: # #

 

(

# #

 = seconds remaining). When the 

entire system is armed, the keypad 

sounds the exit delay alert and 

when the delay expires, the zones 

are armed and the screen displays 

the Shield with the Area icon in 

the center.

ALL?                NO   YES

RESET

1

ABC 

5

MNO

9

YZ

 

2

DEF

 

6

PQR

0

 

3

GHI

 

7

STU

 

4

JKL 

8

VWX

CMD

ALL

CHIME

PERIM

HOME

SLEEP

ALL? NO YES Keypad Display

AREAS:    1  2     4       6 

RESET

1

ABC 

5

MNO

9

YZ

 

2

DEF

 

6

PQR

0

 

3

GHI

 

7

STU

 

4

JKL 

8

VWX

CMD

ALL

CHIME

PERIM

HOME

SLEEP

AREAS: Armed 

Keypad Display 

RESET

1

ABC 

5

MNO

9

YZ

 

2

DEF

 

6

PQR

0

 

3

GHI

 

7

STU

 

4

JKL 

8

VWX

CMD

ALL

CHIME

PERIM

HOME

SLEEP

FRONT DOOR

  

ZONE:       1     -FAULT

  

Zone Fault Keypad Options 

OKAY

  

BYPASS STOP

RESET

1

ABC 

5

MNO

9

YZ

 

2

DEF

 

6

PQR

0

 

3

GHI

 

7

STU

 

4

JKL 

8

VWX

CMD

ALL

CHIME

PERIM

HOME

SLEEP

Okay Bypass Stop 

Keypad Display 

ALL  SYSTEM  ON

RESET

1

ABC 

5

MNO

9

YZ

 

2

DEF

 

6

PQR

0

 

3

GHI

 

7

STU

 

4

JKL 

8

VWX

CMD

ALL

CHIME

PERIM

HOME

SLEEP

ALL SYSTEM ON 

Keypad Display

EXIT TIMER

EXIT TIMER

MON 5:35 PM

3 5

ARM

INSTANT

Exit Timer

ARMED

Panic

Chime

Check-in

Fire Reset

AREA ARMED Display

Summary of Contents for GRAPHIC TOUCHSCREEN KEYPAD

Page 1: ...U S E R S G U I D E GRAPHIC TOUCHSCREEN KEYPAD NOW 90 SAT 71 Reset...

Page 2: ...HIS A FALSE ALARM displays If a burglar alarm is valid press NO to send an alarm verification message to the Central Station If a valid alarm has not occurred press YES to cancel the alarm and send an...

Page 3: ...stant Zone 8 24 Hour Zone 8 Areas 8 Central Station Monitoring 8 Status 8 Status List 8 Zone Status 9 Armed Status 9 Exit Error 9 Arming and Disarming 10 How Your System Operates 10 Arming Functions 1...

Page 4: ...rmation on your system Graphic Touchscreen Keypad Main Screen Your system has an easy to use Graphic Touchscreen Keypad that allows you to operate the system When accessing any other screens you may r...

Page 5: ...easy to understand arming options screen When leaving in a hurry press the shield until it glows the system quick arms the Away system and starts the exit timer giving you ample time to leave Once you...

Page 6: ...tus Blue Steady Panel Disarmed AC Power OK Battery OK Blue Blinking Panel Disarmed AC Power OK Battery Fault No Light Panel Disarmed AC Power Fault Battery OK Red Steady Panel Armed AC Power OK Batter...

Page 7: ...creen prompting entry of a USER CODE Enter your user code to send a Check in Report 3 Chime Press CHIME until it glows This activates MONITOR The System Status displays MONITOR ON in the upper right c...

Page 8: ...needing to disarm and rearm the system 6 Keypad Pressing KEYPAD until it glows displays the Keypad screen This replicates the standard button type keypad Scroll through the User Menu by pressing CMD R...

Page 9: ...en seconds prior to the end of the countdown the rate of pulsing increases Monitor Chime A tone that sounds each time a door or window is opened while you are using the Zone Monitor Chime option from...

Page 10: ...el signal is sent to the Central Station ALARM VERIFIED A valid burglar alarm has occurred and has been manually verified by the user The alarm system also transmits a VERIFY message to the Central St...

Page 11: ...causes the panel to start the entry delay time During the entry delay time enter a valid user code to disarm the system or an alarm occurs Instant Zone Exterior windows and non entry doors or interio...

Page 12: ...n of areas within your security system The screen displays When HOME SYSTEM ON The perimeter areas is armed in a Home Away system PERIMETER ON The perimeter is armed in an All Perimeter system ALL SYS...

Page 13: ...selected areas are arming For Home Away or Home Sleep Away systems the Keypad screen displays ALL SYSTEM ON if all areas in the system are arming HOME SYSTEM ON or SLEEP SYSTEM ON if only selected ar...

Page 14: ...rms but the interior area s remain disarmed because you have not exited Instant During the exit delay time you can cancel the exit and entry delays and cause all zones to be instant zones Press ARM IN...

Page 15: ...if at least one area in the system is armed and ALL SYSTEM ON if all areas in the system are armed 6 The screen then displays the exit time in seconds and counts down the remaining time EXIT seconds...

Page 16: ...is pressed If a valid user code is not entered within 5 seconds or an invalid user code is entered the prewarn tone begins sounding again 2 ALL SYSTEM OFF is displayed in the upper right corner after...

Page 17: ...to send an alarm verify message to the Central Station System Arming Area Systems Your security system is programmed into separate areas Youmayarmanddisarmallareasatonetimeoreachareaindividually You...

Page 18: ...to bypass the zone s before arming 7d Select STOP to stop the system from arming Correct the zone problem s and return to step 1 Note 24 hour zones cannot be bypassed 8 The screen displays SYSTEM ON i...

Page 19: ...ess appear in the display For example AREAS 2 4 To remove an area number from the display press the corresponding number on the screen Press CMD when done 6 After all areas have displayed any alarms t...

Page 20: ...sarming sequence is the same as Area Disarming steps 2 through 6 in the previous section 2 The screen may display ALARM CANCELLED if your system was disarmed after alarm message had been sent to the c...

Page 21: ...those functions to which you have access are displayed Please refer to the user guide provided with your control panel for complete list and operation of the user menu Accessing the User Menu 1 Press...

Page 22: ...tery is either low or missing Contact your service person System Trouble or Service Required Yes There is a problem with one or more components in the system Contact your service person System Busy No...

Page 23: ...tone 6 F Fire alert 6 H Home Sleep Away 2 10 12 14 I Instant Zone 8 Interactive Shield 1 2 12 13 14 Interior 10 11 K keypad 1 3 5 6 7 8 11 12 13 14 15 18 L LED 1 3 M Main Screen 1 2 3 4 5 12 13 14 16...

Page 24: ...Graphic Touchscreen Keypad User s Guide 21...

Page 25: ...LT 1191 1 01 13245...

Reviews: