1100DI Wireless Receiver Installation Guide

4

1100DI Wireless Receiver Installation Guide 

Digital Monitoring Products

5

Transmitter Supervision Time

For NRTL Listed installations, program the transmitter supervision time in panel zone programming as listed in the 

following table.  Refer to the XRSuper6/XR20/XR40 Programming Guide (LT-0305) for complete wireless programming 

information.

UL Listing

Listed Accessories

Supervision 

Time

ANSI/UL  1023  Household Burglary Alarm System Units 

 

 

Accessory

1101/1102/1103 Universal Transmitters

1125 PIR Motion Detector

1142 Two-Button Hold-Up Transmitter

60

60

60

ANSI/UL  636  Holdup Alarm Units and Systems Accessory 1142 Two-Button Hold-Up Transmitter

60

ANSI/UL  634  Connections and Switches for use with 

Burglar Alarm Systems Accessory

1101/1102/1103 Universal Transmitters

60

ANSI/UL  639  Intrusion Detection Units Accessory

1125 PIR Motion Detector

60

ANSI/UL  365  Police Station Connected Burglar Accessory 1103 Universal Transmitter

60

ANSI/UL  609  Local Burglar Alarm Units and System 

Accessory

1103 Universal Transmitter

60

ANSI/UL  1076  Proprietary Burglar Alarm Units Accessory

1103 Universal Transmitter

60

ANSI/UL  1610  Central Station Burglar Alarm Units 

Accessory

1103 Universal Transmitter

60

ANSI/UL  985  Household Fire Warning system Accessory

1101/1102/1103 Universal Transmitter

1161/1162 Residential Smoke Detectors

3

3

Receiver/Panel Software Version Table

The table below provides a list of the required panel and wireless receiver software versions needed to support each 

transmitter.  In each case the version must be the level indicated or higher.

Model

Description

1100DI 

Receiver

XRS6/XR20/XR40 

Panel

1101

Universal Transmitter, Internal/External Contacts

100

300

1102

Universal Transmitter, External Contact

100

300

1114

Four Zone Expander

100

300

1116

Relay Output

104

304

1117

LED Annunciator

104

304

1118

Remote Indicator Light

104

304

1121

PIR Motion Detector

100

300

1125

PIR Motion Detector

100

300

1129

Glassbreak Detector

100

300

1139

Wireless Bill Trap

100

300

1142

Two-Button Hold-Up Transmitter

100

300

1145, 1146, 1147 Four, Two, or One-Button Key Fobs

100

302

1161, 1162

Residential Smoke Detector

100

300

Summary of Contents for 1100DI

Page 1: ...100DI Wireless Receiver The 1100DI Wireless Receiver can be mounted anywhere along the panel keypad bus A location should be selected that will be centrally located between the 1100 Series transmitters used in the installation Install the receiver away from large metal objects Mounting the receiver on or near metal surfaces impairs performance Do not used shielded wire between the panel and receiv...

Page 2: ...e supplied double sided tape Programming the Panel Refer to the XRSuper6 XR20 XR40 Programming Guide LT 0305 as needed In System Options program the House Code 1 50 In Zone Information program the wireless zones 1100DI Receiver Operation The 1100DI receiver automatically sends the panel house code to wireless transmitters when the unique transmitter serial number is programmed into the panel The h...

Page 3: ...00 Series receiver The confirmation is indicated visually by use of an LED on each transmitter This Survey LED should be used during installation to test each transmitter for proper operation A full definition of the Survey LED follows The red LED on an 1100 Series transmitter turns on when the processor wakes up to send a message Then after a series of communication steps are completed successful...

Page 4: ...in troubleshooting LED turns on a single time for less than 1 second 8 to 10 times System is working properly LED turns on for more than 1 second 3 to 9 times The transmitter or receiver needs to be relocated LED turns on for more than 1 second all 10 times The receiver is not turned on or is not operating The transmitter is not programmed into the receiver The transmitter or receiver needs to be ...

Page 5: ...m Units and System Accessory 1103 Universal Transmitter 60 ANSI UL 1076 Proprietary Burglar Alarm Units Accessory 1103 Universal Transmitter 60 ANSI UL 1610 Central Station Burglar Alarm Units Accessory 1103 Universal Transmitter 60 ANSI UL 985 Household Fire Warning system Accessory 1101 1102 1103 Universal Transmitter 1161 1162 Residential Smoke Detectors 3 3 Receiver Panel Software Version Tabl...

Page 6: ... installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a ...

Reviews: