DIGITAL-LOGIC AG
MPC25/26 Manual V1.1
22
Operating Environment
Specifications
Relative Humidity
5 - 90% non-condensing
IEC68-2-30 at -+5 to +50°C operating
Vibration Operating
IEC68-2-6 10-50Hz, 0.075mm and 55-500Hz, 1.0G
Vibration Non-operating
IEC68-2-6 10-50Hz, 0.15mm and 55-500Hz, 2.0G
Shock Operating
IEC68-2-27 10G, 11ms ½ sine
Shock Non-operating
IEC68-2-27 50G, 11ms, ½ sine
Altitude
IEC68-2-13 4571meter operating
Temperature Operating
IEC68-2-1,2,14 (see separate table below)
Temperature Storage
IEC68-2-1,2,14: -40°C to +70°C
Operating Temperature
Specifications
Without hard drive
-25°C to +70°C
With standard hard drive
0°C to +50°C
With extended temp. hard drive
-25°C to +70°C
EMI / EMC Tests
Specifications
EMC Emission EN61000-6-2:2001
Conducted disturbance
EN55022 Class B
Radiated disturbance
EN55022 Class B
EMC Immunity EN61000-6-2
Electro-Static Discharge (ESD)
EN61000-4-2
Voltage = 4kV contact / 8kV air
Criteria A
Radiated RF field
EN61000-4-3
Level = 10V/m
Criteria A
Electrical fast transients (burst)
EN61000-4-4
Grade 2: DC-Power lines = 1000V (5/50ns)
Grade 2: AC-Power lines = 2000V (5/50ns)
Grade 2: Signal lines = 500V (5/50ns)
Criteria B
Surge
EN61000-4-5
Grade 2: DC-Power lines = 1kV, (1.2/50us)
Grade 2: AC-Power lines = 2kV, (1.2/50us)
Criteria B
Conducted disturbances
EN61000-4-6
Voltage = 10V coupled by case
Criteria A
Security
:
e1:
Not planned
UL
Not planned
ETL 301
Not planned
SEV
Safety
AR385-16
Summary of Contents for MPC25/L
Page 12: ...DIGITAL LOGIC AG MPC25 26 Manual V1 1 12 1 14 EC Declaration of Conformity MPC25...
Page 13: ...DIGITAL LOGIC AG MPC25 26 Manual V1 1 13 1 15 EC Declaration of Conformity MPC25L...
Page 14: ...DIGITAL LOGIC AG MPC25 26 Manual V1 1 14 1 16 EC Declaration of Conformity MPC26...
Page 15: ...DIGITAL LOGIC AG MPC25 26 Manual V1 1 15 1 17 EMV Certificate MPC25 26...